Bioprosthetic Valve Fracture to Facilitate Transcatheter Valve-in-Valve Implantation

被引:117
作者
Allen, Keith B.
Chhatriwalla, Adnan K.
Cohen, David J.
Saxon, John T.
Aggarwal, Sanjeev
Hart, Anthony
Baron, Suzanne
Davis, J. Russell
Pak, Alex F.
Dvir, Danny
Borkon, A. Michael
机构
[1] St Lukes Mid Amer Heart Inst, Kansas City, MO USA
[2] Univ Missouri, Kansas City, MO 64110 USA
[3] St Pauls Hosp, Vancouver, BC, Canada
关键词
PROSTHESIS-PATIENT MISMATCH; PERIMOUNT BIOPROSTHESIS; RISK PATIENTS; REPLACEMENT; CRACKING;
D O I
10.1016/j.athoracsur.2017.04.007
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Valve-in-valve transcatheter aortic valve replacement is less effective in small surgical bioprostheses. We evaluated the feasibility of bioprosthetic valve fracture with a high-pressure balloon to facilitate valve-in-valve transcatheter aortic valve replacement.& para;& para;Methods. In vitro bench testing on aortic tissue valves was performed on 19-mm and 21-mm Mitroflow (Sorin, Milan, Italy), Magna and Magna Ease (Edwards Life-sciences, Irvine, CA), Trifecta and Biocor Epic (St. Jude Medical, Minneapolis, MN), and Hancock II and Mosaic (Medtronic, Minneapolis, MN). High-pressure balloons Tru Dilation, Atlas Gold, and Dorado (C.R. Bard, Murray Hill, NJ) were used to determine which valves could be fractured and at what pressure fracture occurred.& para;& para;Results. Mitroflow, Magna, Magna Ease, Mosaic, and Biocor Epic surgical valves were successfully fractured using high-pressures balloon 1 mm larger than the labeled valve size whereas Trifecta and Hancock II surgical valves could not be fractured. Only the internal valve frame was fractured, and the sewing cuff was never disrupted. Manufacturer's rated burst pressures for balloons were exceeded, with fracture pressures ranging from 8 to 24 atmospheres depending on the surgical valve. Testing further demonstrated that fracture facilitated the expansion of previously constrained, underexpanded transcatheter valves (both balloon and self-expanding) to the manufacturer's recommended size.& para;& para;Conclusions. Bench testing demonstrates that the frame of most, but not all, bioprosthetic surgical aortic valves can be fractured using high-pressure balloons. The safety of bioprosthetic valve fracture to optimize valve-in-valve transcatheter aortic valve replacement in small surgical valves requires further clinical investigation. (C) 2017 by The Society of Thoracic Surgeons
引用
收藏
页码:1501 / 1508
页数:8
相关论文
共 13 条
[1]   Transcatheter Aortic-Valve Replacement with a Self-Expanding Prosthesis [J].
Adams, David H. ;
Popma, Jeffrey J. ;
Reardon, Michael J. ;
Yakubov, Steven J. ;
Coselli, Joseph S. ;
Deeb, G. Michael ;
Gleason, Thomas G. ;
Buchbinder, Maurice ;
Hermiller, James, Jr. ;
Kleiman, Neal S. ;
Chetcuti, Stan ;
Heiser, John ;
Merhi, William ;
Zorn, George ;
Tadros, Peter ;
Robinson, Newell ;
Petrossian, George ;
Hughes, G. Chad ;
Harrison, J. Kevin ;
Conte, John ;
Maini, Brijeshwar ;
Mumtaz, Mubashir ;
Chenoweth, Sharla ;
Oh, Jae K. .
NEW ENGLAND JOURNAL OF MEDICINE, 2014, 370 (19) :1790-1798
[2]  
[Anonymous], 2016, US Patent, Patent No. [9375310 B2, 9375310]
[3]   Cracking a Tricuspid Perimount Bioprosthesis to Optimize a Second Transcatheter Sapien Valve-in-Valve Placement [J].
Brown, Stephen C. ;
Cools, Bjorn ;
Gewillig, Marc .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2016, 88 (03) :456-459
[4]   Predictors and Outcomes of Prosthesis-Patient Mismatch After Aortic Valve Replacement [J].
Dayan, Victor ;
Vignolo, Gustavo ;
Soca, Gerardo ;
Paganini, Juan Jose ;
Brusich, Daniel ;
Pibarot, Philippe .
JACC-CARDIOVASCULAR IMAGING, 2016, 9 (08) :924-933
[5]   Transcatheter Aortic Valve Implantation in Failed Bioprosthetic Surgical Valves [J].
Dvir, Danny ;
Webb, John G. ;
Bleiziffer, Sabine ;
Pasic, Miralem ;
Waksman, Ron ;
Kodali, Susheel ;
Barbanti, Marco ;
Latib, Azeem ;
Schaefer, Ulrich ;
Rodes-Cabau, Josep ;
Treede, Hendrik ;
Piazza, Nicolo ;
Hildick-Smith, David ;
Himbert, Dominique ;
Walther, Thomas ;
Hengstenberg, Christian ;
Nissen, Henrik ;
Bekeredjian, Raffi ;
Presbitero, Patrizia ;
Ferrari, Enrico ;
Segev, Amit ;
de Weger, Arend ;
Windecker, Stephan ;
Moat, Neil E. ;
Napodano, Massimo ;
Wilbring, Manuel ;
Cerillo, Alfredo G. ;
Brecker, Stephen ;
Tchetche, Didier ;
Lefevre, Thierry ;
De Marco, Federico ;
Fiorina, Claudia ;
Petronio, Anna Sonia ;
Teles, Rui C. ;
Testa, Luca ;
Laborde, Jean-Claude ;
Leon, Martin B. ;
Kornowski, Ran .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2014, 312 (02) :162-170
[6]   Concept of an expandable cardiac valve for surgical implantation in infants and children [J].
Emani, Sitaram M. ;
Piekarski, Breanna L. ;
Zurakowski, David ;
Baird, Christopher A. ;
Marshall, Audrey C. ;
Lock, James E. ;
del Nido, Pedro J. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2016, 152 (06) :1514-1522
[7]   Valve-in-Valve Transcatheter Aortic Valve Implantation: The New Playground for Prosthesis-Patient Mismatch [J].
Faerber, Gloria ;
Schleger, Simone ;
Diab, Mahmoud ;
Breuer, Martin ;
Figulla, Hans R. ;
Eichinger, Walter B. ;
Doenst, Torsten .
JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2014, 27 (03) :287-292
[8]   Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients [J].
Leon, Martin B. ;
Smith, Craig R. ;
Mack, Michael J. ;
Makkar, Raj R. ;
Svensson, Lars G. ;
Kodali, Susheel K. ;
Thourani, Vinod H. ;
Tuzcu, E. Murat ;
Miller, D. Craig ;
Herrmann, Howard C. ;
Doshi, Darshan ;
Cohen, David J. ;
Pichard, Augusto D. ;
Kapadia, Samir ;
Dewey, Todd ;
Babaliaros, Vasilis ;
Szeto, Wilson Y. ;
Williams, Mathew R. ;
Kereiakes, Dean ;
Zajarias, Alan ;
Greason, Kevin L. ;
Whisenant, Brian K. ;
Hodson, Robert W. ;
Moses, Jeffrey W. ;
Trento, Alfredo ;
Brown, David L. ;
Fearon, William F. ;
Pibarot, Philippe ;
Hahn, Rebecca T. ;
Jaber, Wael A. ;
Anderson, William N. ;
Alu, Maria C. ;
Webb, John G. .
NEW ENGLAND JOURNAL OF MEDICINE, 2016, 374 (17) :1609-1620
[9]   Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery. [J].
Leon, Martin B. ;
Smith, Craig R. ;
Mack, Michael ;
Miller, D. Craig ;
Moses, Jeffrey W. ;
Svensson, Lars G. ;
Tuzcu, E. Murat ;
Webb, John G. ;
Fontana, Gregory P. ;
Makkar, Raj R. ;
Brown, David L. ;
Block, Peter C. ;
Guyton, Robert A. ;
Pichard, Augusto D. ;
Bavaria, Joseph E. ;
Herrmann, Howard C. ;
Douglas, Pamela S. ;
Petersen, John L. ;
Akin, Jodi J. ;
Anderson, William N. ;
Wang, Duolao ;
Pocock, Stuart .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (17) :1597-1607
[10]   Fracturing the Ring of Small Mitroflow Bioprostheses by High-Pressure Balloon Predilatation in Transcatheter Aortic Valve-in-Valve Implantation [J].
Nielsen-Kudsk, Jens Erik ;
Christiansen, Evald Hoj ;
Terkelsen, Christian Juhl ;
Norgaard, Bjarne Linde ;
Jensen, Kaare Troels ;
Krusell, Lars Romer ;
Tang, Mariann ;
Terp, Kim ;
Klaaborg, Kaj-Erik ;
Andersen, Henning Rud .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (08)