Iodine Quantification With Dual-Energy CT: Phantom Study and Preliminary Experience With Renal Masses

被引:190
作者
Chandarana, Hersh [1 ]
Megibow, Alec J. [1 ]
Cohen, Benjamin A. [1 ]
Srinivasan, Ramya [1 ]
Kim, Danny [1 ]
Leidecker, Christianne [2 ]
Macari, Michael [1 ]
机构
[1] NYU, Langone Med Ctr, Dept Radiol, New York, NY 10016 USA
[2] Siemens Healthcare, Malvern, PA USA
关键词
dual-energy CT; iodine quantification; renal lesion; renal mass; CELL CARCINOMA; MULTIDETECTOR CT; HELICAL CT; PORCINE MODEL; ENHANCEMENT; DIFFERENTIATION; ATTENUATION; TUMORS; FEASIBILITY; SUNITINIB;
D O I
10.2214/AJR.10.5541
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to validate the utility of dual-source dual-energy MDCT in quantifying iodine concentration in a phantom and in renal masses. MATERIALS AND METHODS. A series of tubes containing solutions of varying iodine concentration were imaged with dual-source dual-energy MDCT. Iodine concentration was calculated and compared with known iodine concentration. Single-phase contrast-enhanced dual-source dual-energy MDCT data on 15 patients with renal lesions then were assessed independently by two readers. Dual-energy postprocessing was used to generate iodine-only images. Regions of interest were placed on the iodine image over the lesion and, as a reference, over the aorta, for recording of iodine concentration in the lesion and in the aorta. Another radiologist determined lesion enhancement by comparing truly unenhanced with contrast-enhanced images. Mixed-model analysis of variance based on ranks was used to compare lesion types (simple cyst, hemorrhagic cyst, enhancing mass) in terms of lesion iodine concentration and lesion-to-aorta iodine ratio. RESULTS. In the phantom study, there was excellent correlation between calculated and true iodine concentration (R(2) = 0.998, p < 0.0001). In the patient study, 13 nonenhancing (10 simple and three hyperdense cysts) and eight enhancing renal masses were evaluated in 15 patients. The lesion iodine concentration and lesion-to-aorta iodine ratio in enhancing masses were significantly higher than in hyperdense and simple cysts (p < 0.0001). CONCLUSION. Iodine quantification with dual-source dual-energy MDCT is accurate in a phantom and can be used to determine the presence and concentration of iodine in a renal lesion. Characterization of renal masses may be possible with a single dual-source dual-energy MDCT acquisition without unenhanced images or reliance on a change in attenuation measurements.
引用
收藏
页码:W693 / W700
页数:8
相关论文
共 36 条
[1]   Aortic and hepatic contrast medium enhancement at CT part II. Effect of reduced cardiac output in a porcine model [J].
Bae, KT ;
Heiken, JP ;
Brink, JA .
RADIOLOGY, 1998, 207 (03) :657-662
[2]   Aortic and hepatic peak enhancement at CT: Effect of contrast medium injection rate - Pharmacokinetic analysis and experimental porcine model [J].
Bae, KT ;
Heiken, JP ;
Brink, JA .
RADIOLOGY, 1998, 206 (02) :455-464
[3]   Renal cyst pseudoenhancement: Influence of multidetector CT reconstruction algorithm and scanner type in phantom model [J].
Birnbaum, Bernard A. ;
Hindman, Nicole ;
Lee, Julie ;
Babb, James S. .
RADIOLOGY, 2007, 244 (03) :767-775
[4]   Multi-detector row CT attenuation measurements: Assessment of intra- and interscanner variability with an anthropomorphic body CT phantom [J].
Birnbaum, Bernard A. ;
Hindman, Nicole ;
Lee, Julie ;
Babb, James S. .
RADIOLOGY, 2007, 242 (01) :109-119
[5]   Dual-energy CT iodine overlay technique for characterization of renal masses as cyst or solid: a phantom feasibility study [J].
Brown, C. L. ;
Hartman, R. P. ;
Dzyubak, O. P. ;
Takahashi, N. ;
Kawashima, A. ;
McCollough, C. H. ;
Bruesewitz, M. R. ;
Primak, A. M. ;
Fletcher, J. G. .
EUROPEAN RADIOLOGY, 2009, 19 (05) :1289-1295
[6]   Abdominal Aorta: Evaluation with Dual-Source Dual-Energy Multidetector CT after Endovascular Repair of Aneurysms-Initial Observations [J].
Chandarana, Hersh ;
Godoy, Myrna C. B. ;
Vlahos, Ioannis ;
Graser, Anno ;
Babb, James ;
Leidecker, Christianne ;
Macari, Michael .
RADIOLOGY, 2008, 249 (02) :692-700
[7]   Critical issues in response evaluation on computed tomography: Lessons from the gastrointestinal stromal tumor model [J].
Choi H. .
Current Oncology Reports, 2005, 7 (4) :307-311
[8]   Analysis of changes in attenuation of proven renal cysts on different scanning phases of triphasic MDCT [J].
Chung, EP ;
Herts, BR ;
Linnell, G ;
Novick, AC ;
Obuchowski, N ;
Coll, DM ;
Baker, ME .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (02) :405-410
[9]   Tumor angiogenesis:: pathophysiology and implications for contrast-enhanced MRI and CT assessment [J].
Cuenod, CA ;
Fournier, L ;
Balvay, D ;
Guinebretière, JM .
ABDOMINAL IMAGING, 2006, 31 (02) :188-193
[10]   Dual-Energy and Dual-Source CT: Is There a Role in the Abdomen and Pelvis? [J].
Fletcher, Joel G. ;
Takahashi, Naoki ;
Hartman, Robert ;
Guimaraes, Luis ;
Huprich, James E. ;
Hough, David M. ;
Yu, Lifeng ;
McCollough, Cynthia H. .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2009, 47 (01) :41-+