All-Solid-State Reference Electrodes Based on Colloid-Imprinted Mesoporous Carbon and Their Application in Disposable Paper-based Potentiometric Sensing Devices

被引:93
作者
Hu, Jinbo [1 ]
Ho, Kieu T. [1 ]
Zou, Xu U. [1 ]
Smyrl, William H. [2 ]
Stein, Andreas [1 ]
Buehlmann, Philippe [1 ]
机构
[1] Univ Minnesota, Dept Chem, Minneapolis, MN 55455 USA
[2] Univ Minnesota, Dept Chem Engn & Mat Sci, Minneapolis, MN 55455 USA
关键词
ION-SELECTIVE ELECTRODES; ORDERED MACROPOROUS CARBON; LIQUID-JUNCTION; NANOTUBES; IONOPHORE; MEMBRANE; CONTACT; TRANSDUCER; CELL;
D O I
10.1021/ac504556s
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Reference electrodes are used in almost every electroanalytical measurement. Here, all-solid-state reference electrodes are described that employ colloid-imprinted mesoporous (CIM) carbon as solid contact and a poly(vinyl chloride) reference membrane to contact the sample. Such a reference membrane is doped with a moderately hydrophilic ionic liquid and a hydrophobic redox couple, leading to well-defined constant potentials at the interfaces of this membrane to the sample and to the solid contact, respectively. Due to the intrinsic properties of CIM carbon, reference electrodes with a CIM carbon solid contact exhibit excellent resistance to common interfering agents such as light and O-2, with outstanding potential stability in continuous potentiometric measurements. The potential drift of CIM carbon-based reference electrodes without redox couple is as low as 1.7 mu V/h over 110 h, making them the most stable all-solid-state reference electrodes reported so far. To demonstrate the compatibility of CIM carbon-based reference electrodes with miniaturized potentiometric systems, these reference electrodes were integrated into paper-based potentiometric sensing devices, successfully replacing the conventional reference electrode with its reference electrolyte solution. As a proof of concept, disposable paper-based Cl sensing devices that contain stencil-printed Ag/AgCl-based Cl- selective electrodes and CIM carbon-based reference electrodes were constructed. These sensing devices are inexpensive, easy to use, and offer highly reproducible Cl- measurements with sample volumes as low as 10 mu L.
引用
收藏
页码:2981 / 2987
页数:7
相关论文
共 46 条
[11]   Potentiometric sensing utilizing paper-based microfluidic sampling [J].
Cui, Jingwen ;
Lisak, Grzegorz ;
Strzalkowska, Sylwia ;
Bobacka, Johan .
ANALYST, 2014, 139 (09) :2133-2136
[12]   REFERENCE ELECTRODE WITH FREE-FLOWING FREE-DIFFUSION LIQUID JUNCTION [J].
DOHNER, RE ;
WEGMANN, D ;
MORF, WE ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1986, 58 (12) :2585-2589
[13]   HYPERTONIC VERSUS ISOTONIC SALT BRIDGES IN ION-SELECTIVE ELECTRODE BASED CLINICAL ANALYZERS [J].
DORAZIO, P .
ANNALS OF CLINICAL BIOCHEMISTRY, 1991, 28 :628-629
[14]  
Fibbioli M, 2000, ELECTROANAL, V12, P1286, DOI 10.1002/1521-4109(200011)12:16<1286::AID-ELAN1286>3.3.CO
[15]  
2-H
[16]   Effects of Architecture and Surface Chemistry of Three-Dimensionally Ordered Macroporous Carbon Solid Contacts on Performance of Ion-Selective Electrodes [J].
Fierke, Melissa A. ;
Lai, Chun-Ze ;
Buhlmann, Philippe ;
Stein, Andreas .
ANALYTICAL CHEMISTRY, 2010, 82 (02) :680-688
[17]   Ion-Selective Electrodes with Colloid-Imprinted Mesoporous Carbon as Solid Contact [J].
Hu, Jinbo ;
Zou, Xu U. ;
Stein, Andreas ;
Buehlmann, Philippe .
ANALYTICAL CHEMISTRY, 2014, 86 (14) :7111-7118
[18]   Ionophore-based ion-selective potentiometric and optical sensors [J].
Johnson, RD ;
Bachas, LG .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 376 (03) :328-341
[19]  
Kakiuhi T., 2006, B CHEM SOC JPN, V79, P1017
[20]   All-solid-state reference electrodes based on conducting polymers [J].
Kisiel, A ;
Marcisz, H ;
Michalska, A ;
Maksymiuk, K .
ANALYST, 2005, 130 (12) :1655-1662