All-Solid-State Reference Electrodes Based on Colloid-Imprinted Mesoporous Carbon and Their Application in Disposable Paper-based Potentiometric Sensing Devices

被引:93
作者
Hu, Jinbo [1 ]
Ho, Kieu T. [1 ]
Zou, Xu U. [1 ]
Smyrl, William H. [2 ]
Stein, Andreas [1 ]
Buehlmann, Philippe [1 ]
机构
[1] Univ Minnesota, Dept Chem, Minneapolis, MN 55455 USA
[2] Univ Minnesota, Dept Chem Engn & Mat Sci, Minneapolis, MN 55455 USA
关键词
ION-SELECTIVE ELECTRODES; ORDERED MACROPOROUS CARBON; LIQUID-JUNCTION; NANOTUBES; IONOPHORE; MEMBRANE; CONTACT; TRANSDUCER; CELL;
D O I
10.1021/ac504556s
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Reference electrodes are used in almost every electroanalytical measurement. Here, all-solid-state reference electrodes are described that employ colloid-imprinted mesoporous (CIM) carbon as solid contact and a poly(vinyl chloride) reference membrane to contact the sample. Such a reference membrane is doped with a moderately hydrophilic ionic liquid and a hydrophobic redox couple, leading to well-defined constant potentials at the interfaces of this membrane to the sample and to the solid contact, respectively. Due to the intrinsic properties of CIM carbon, reference electrodes with a CIM carbon solid contact exhibit excellent resistance to common interfering agents such as light and O-2, with outstanding potential stability in continuous potentiometric measurements. The potential drift of CIM carbon-based reference electrodes without redox couple is as low as 1.7 mu V/h over 110 h, making them the most stable all-solid-state reference electrodes reported so far. To demonstrate the compatibility of CIM carbon-based reference electrodes with miniaturized potentiometric systems, these reference electrodes were integrated into paper-based potentiometric sensing devices, successfully replacing the conventional reference electrode with its reference electrolyte solution. As a proof of concept, disposable paper-based Cl sensing devices that contain stencil-printed Ag/AgCl-based Cl- selective electrodes and CIM carbon-based reference electrodes were constructed. These sensing devices are inexpensive, easy to use, and offer highly reproducible Cl- measurements with sample volumes as low as 10 mu L.
引用
收藏
页码:2981 / 2987
页数:7
相关论文
共 46 条
[1]  
Amemiya S, 2007, HANDBOOK OF ELECTROCHEMISTRY, P261, DOI 10.1016/B978-044451958-0.50020-3
[2]  
[Anonymous], 2012, Supramolecular Chemistry
[3]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[4]   Modern Potentiometry [J].
Bakker, Eric ;
Pretsch, Ernoe .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2007, 46 (30) :5660-5668
[5]   Potentiometric ion sensors [J].
Bobacka, Johan ;
Ivaska, Ari ;
Lewenstam, Andrzej .
CHEMICAL REVIEWS, 2008, 108 (02) :329-351
[6]   ALL-SOLID-STATE SODIUM-SELECTIVE ELECTRODE BASED ON A CALIXARENE IONOPHORE IN A POLY(VINYL CHLORIDE) MEMBRANE WITH A POLYPYRROLE SOLID CONTACT [J].
CADOGAN, A ;
GAO, ZQ ;
LEWENSTAM, A ;
IVASKA, A ;
DIAMOND, D .
ANALYTICAL CHEMISTRY, 1992, 64 (21) :2496-2501
[7]   Understanding Wax Printing: A Simple Micropatterning Process for Paper-Based Microfluidics [J].
Carrilho, Emanuel ;
Martinez, Andres W. ;
Whitesides, George M. .
ANALYTICAL CHEMISTRY, 2009, 81 (16) :7091-7095
[8]   Recent Developments in Paper-Based Microfluidic Devices [J].
Cate, David M. ;
Adkins, Jaclyn A. ;
Mettakoonpitak, Jaruwan ;
Henry, Charles S. .
ANALYTICAL CHEMISTRY, 2015, 87 (01) :19-41
[9]   Ionic Liquid-Based, Liquid-Junction-Free Reference Electrode [J].
Cicmil, Dimitrije ;
Anastasova, Salzitsa ;
Kavanagh, Andrew ;
Diamond, Dermot ;
Mattinen, Ulriika ;
Bobacka, Johan ;
Lewenstam, Andrzej ;
Radu, Aleksandar .
ELECTROANALYSIS, 2011, 23 (08) :1881-1890
[10]   Ion-selective electrodes using carbon nanotubes as ion-to-electron transducers [J].
Crespo, Gaston A. ;
Macho, Santiago ;
Xavier Rius, F. .
ANALYTICAL CHEMISTRY, 2008, 80 (04) :1316-1322