摘要
Background Our study aimed to assess and compare the accuracy of 8 intraocular lens (IOL) power calculation formulas (Barrett Universal II, EVO 2.0, Haigis, Hoffer Q, Holladay 1, Kane and PEARL-DGS) in patients submitted to combined phacovitrectomy for vitreomacular (VM) interface disorders. Methods Retrospective chart review study including axial-length matched patients submitted to phacoemulsification alone (Group 1) and combined phacovitrectomy (Group 2). Using optimized constants in both groups, refraction prediction error of each formula was calculated for each eye. The optimised constants from Group 1 were also applied to patients of Group 2 - Group 3. Outcome measures included the mean prediction error (ME) and its standard deviation (SD), mean (MAE) and median (MedAE) absolute errors, in diopters (D), and the percentage of eyes within +/- 0.25D, +/- 0.50D and +/- 1.00D. Results A total of 220 eyes were included (Group 1: 100; Group 2: 120). In Group 1, the difference in formulas absolute error was significative (p = 0.005). The Kane Formula had the lowest MAE (0.306) and MedAE (0.264). In Group 2, Kane had the overall best performance, followed by PEARL-DGS, EVO 2.0 and Barrett Universal II. The ME of all formulas in both Groups 1 and 2 were 0.000 (p = 0.934; p = 0.971, respectively). In Group 3, a statistically significant myopic shift was observed for each formula (p < 0.001). Conclusion Surgeons must be careful regarding IOL power selection in phacovitrectomy considering the systematic myopic shift evidenced-constant optimization may help eliminating such error. Moreover, newly introduced formulas and calculation methods may help us achieving increasingly better refractive outcomes both in cataract surgery alone and phacovitrectomy.
引用
收藏
页数:8
相关论文
共 36 条
[11]   Epiretinal membrane surgery: an analysis of 2-step sequential- or combined phacovitrectomy surgery on refraction and macular anatomy in a prospective trial [J].
Hamoudi, Hassan ;
Christensen, Ulrik Correll ;
La Cour, Morten .
ACTA OPHTHALMOLOGICA, 2018, 96 (03) :243-250
[12]   Protocols for Studies of Intraocular Lens Formula Accuracy [J].
Hoffer, Kenneth J. ;
Aramberri, Jaime ;
Haigis, Wolfgang ;
Olsen, Thomas ;
Savini, Giacomo ;
Shammas, H. John ;
Bentow, Stanley .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 160 (03) :403-405
[14]   A 3-PART SYSTEM FOR REFINING INTRAOCULAR-LENS POWER CALCULATIONS [J].
HOLLADAY, JT ;
PRAGER, TC ;
CHANDLER, TY ;
MUSGROVE, KH ;
LEWIS, JW ;
RUIZ, RS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1988, 14 (01) :17-24
[15]   Post-operative Refractive Prediction Error After Phacovitrectomy: A Retrospective Study [J].
Hotte, Gijsbert J. ;
de Bruyn, Daniel P. ;
de Hoog, Joeri .
OPHTHALMOLOGY AND THERAPY, 2018, 7 (01) :83-94
[16]   Investigation of the stability of one-piece acrylic intraocular lenses in cataract surgery and in combined vitrectomy surgery [J].
Iwase, T. ;
Sugiyama, K. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2006, 90 (12) :1519-1523
[17]   Factors influencing refractive outcomes after combined phaco emulsification and pars plana vitrectomy - Results of a prospective study [J].
Jeoung, Jin Wook ;
Chung, Hum ;
Yu, Hyeong Gon .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (01) :108-114
[18]   Intraocular lens power formula accuracy: Comparison of 7 formulas [J].
Kane, Jack X. ;
van Heerden, Anton ;
Atik, Alp ;
Petsoglou, Constantinos .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (10) :1490-1500
[19]   Optical biometry in combined phacovitrectomy [J].
Manvikar, Sridhar R. ;
Allen, David ;
Steel, David H. W. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (01) :64-69
[20]   Update on Intraocular Lens Calculation Formulas [J].
Melles, Ronald B. ;
Kane, Jack X. ;
Olsen, Thomas ;
Chang, William J. .
OPHTHALMOLOGY, 2019, 126 (09) :1334-1335