Intraocular lens power calculation formulas accuracy in combined phacovitrectomy: an 8-formulas comparison study

被引:15
作者
Hipolito-Fernandes, Diogo [1 ]
Luis, Maria Elisa [1 ]
Maleita, Diogo [1 ]
Gil, Pedro [1 ]
Maduro, Vitor [1 ]
Costa, Livio [1 ]
Marques, Nuno [1 ]
Branco, Joao [1 ]
Alves, Nuno [1 ]
机构
[1] Ctr Hosp Univ Lisboa Cent, Dept Ophthalmol, Alameda Santo Antonio dos Capuchos, P-1169050 Lisbon, Portugal
关键词
Vitreomacular interface disorders; Phavocitrectomy; Intraocular lens power; Formulas accuracy; PARS-PLANA VITRECTOMY; CATARACT-SURGERY; REFRACTIVE OUTCOMES; EYES; PHACOEMULSIFICATION; BIOMETRY; IMPLANTATION;
D O I
10.1186/s40942-021-00315-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background Our study aimed to assess and compare the accuracy of 8 intraocular lens (IOL) power calculation formulas (Barrett Universal II, EVO 2.0, Haigis, Hoffer Q, Holladay 1, Kane and PEARL-DGS) in patients submitted to combined phacovitrectomy for vitreomacular (VM) interface disorders. Methods Retrospective chart review study including axial-length matched patients submitted to phacoemulsification alone (Group 1) and combined phacovitrectomy (Group 2). Using optimized constants in both groups, refraction prediction error of each formula was calculated for each eye. The optimised constants from Group 1 were also applied to patients of Group 2 - Group 3. Outcome measures included the mean prediction error (ME) and its standard deviation (SD), mean (MAE) and median (MedAE) absolute errors, in diopters (D), and the percentage of eyes within +/- 0.25D, +/- 0.50D and +/- 1.00D. Results A total of 220 eyes were included (Group 1: 100; Group 2: 120). In Group 1, the difference in formulas absolute error was significative (p = 0.005). The Kane Formula had the lowest MAE (0.306) and MedAE (0.264). In Group 2, Kane had the overall best performance, followed by PEARL-DGS, EVO 2.0 and Barrett Universal II. The ME of all formulas in both Groups 1 and 2 were 0.000 (p = 0.934; p = 0.971, respectively). In Group 3, a statistically significant myopic shift was observed for each formula (p < 0.001). Conclusion Surgeons must be careful regarding IOL power selection in phacovitrectomy considering the systematic myopic shift evidenced-constant optimization may help eliminating such error. Moreover, newly introduced formulas and calculation methods may help us achieving increasingly better refractive outcomes both in cataract surgery alone and phacovitrectomy.
引用
收藏
页数:8
相关论文
共 36 条
[1]   Statistical Analysis for Studies of Intraocular Lens Formula Accuracy [J].
Aristodemou, Petros ;
Cartwright, Nathaniel E. Knox ;
Sparrow, John M. ;
Johnston, Robert L. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 160 (05) :1085-1086
[2]   Refractive Predictability Using the IOLMaster 700 and Artificial Intelligence-Based IOL Power Formulas Compared to Standard Formulas [J].
Cheng, Huanhuan ;
Kane, Jack X. ;
Liu, Liangping ;
Li, Jianbing ;
Cheng, Bing ;
Wu, Mingxing .
JOURNAL OF REFRACTIVE SURGERY, 2020, 36 (07) :466-+
[3]   Cataract extraction after retinal detachment repair by vitrectomy : visual outcome and complications [J].
Cole, C. J. ;
Charteris, D. G. .
EYE, 2009, 23 (06) :1377-1381
[4]   Comparison of the Kane formula with existing formulas for intraocular lens power selection [J].
Connell, Benjamin J. ;
Kane, Jack X. .
BMJ OPEN OPHTHALMOLOGY, 2019, 4 (01)
[5]   Comparison of 9 intraocular lens power calculation formulas [J].
Cooke, David L. ;
Cooke, Timothy L. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (08) :1157-1164
[6]   Assessment of the accuracy of new and updated intraocular lens power calculation formulas in 10 930 eyes from the UK National Health Service [J].
Darcy, Kieren ;
Gunn, David ;
Tavassoli, Shokufeh ;
Sparrow, John ;
Kane, Jack X. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (01) :2-7
[7]   Combined phacoemulsification, intraocular lens implantation, and vitrectomy for eyes with coexisting cataract and vitreoretinal pathology [J].
Demetriades, AM ;
Gottsch, JD ;
Thomsen, R ;
Azab, A ;
Stark, WJ ;
Campochiaro, PA ;
De Juan, E ;
Haller, JA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 135 (03) :291-296
[8]   Refractive outcome comparison between vitreomacular interface disorders after phacovitrectomy [J].
Ercan, Zeynep Eylul ;
Akkoyun, Imren ;
Pinarci, Eylem Yaman ;
Yilmaz, Gursel ;
Topcu, Hulya .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (08) :1068-1071
[9]   Accuracy of preoperative biometry in vitrectomy combined with cataract surgery for patients with epiretinal membranes and macular holes Results of a prospective controlled clinical trial [J].
Falkner-Radler, Christiane I. ;
Benesch, Thomas ;
Binder, Susanne .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (10) :1754-1760
[10]   Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis [J].
Haigis, W ;
Lege, B ;
Miller, N ;
Schneider, B .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2000, 238 (09) :765-773