Analysis of electrical energy efficiency using LED in the bank building (Study case in Bank X)

被引:0
作者
Parjiman, P. [1 ]
Rahardjo, I. A. [1 ]
Subekti, M. [1 ]
Sunawar, A. [1 ]
机构
[1] Univ State Jakarta, Elect Engn Educ Program, Rawamangun, Indonesia
来源
5TH ANNUAL APPLIED SCIENCE AND ENGINEERING CONFERENCE (AASEC 2020) | 2021年 / 1098卷
关键词
AUDIT; HOT;
D O I
10.1088/1757-899X/1098/4/042030
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
This study aims to analyse the efficiency of electrical energy by utilizing LED lights in the bank building in replacing fluorescent type lamps which can later be used as a basis for consideration of energy efficiency. This research was conducted using a qualitative description method by observing and measuring initial conditions, then conducting an analysis to calculate efficiency. To carry out energy efficiency analysis begins with an ideal plan for the need for lighting intensity according to the standard using LED lamp. Research activities began by collecting data covering the location and specifications of the building, detailed drawings in the form of ass built drawings related to electricity, lighting, and lighting equipment's throughout the building. Then measure lighting intensity and illumination power. Measurement data were analysed against SNI 6197-2011 standard and carried out a plan to replace existing lamps using LED type lamps as energy efficiency. Then draw conclusions about energy efficiency by replacing LED lights. Based on data analysis of lighting intensity that there is 104 rooms or 55.32 % of 188 rooms measured that have not been accord to standard SNI 6197-2011. And analysis of illumination power that there is 55 rooms or 29.26 % of 188 rooms measured that have not been accord to standard SNI 6197-2011. If all of TL fluorescent lamps are replaced by LED lamps, and some rooms that less illumination power are improved the with LED lamps, so the total efficiency of electrical energy in the Bank Building is approximately 18 (eighteen) percent.
引用
收藏
页数:4
相关论文
共 11 条
  • [1] Energy audit of an educational building in a hot summer climate
    Alajmi, Ali
    [J]. ENERGY AND BUILDINGS, 2012, 47 : 122 - 130
  • [2] [Anonymous], 2011, 61972011 SNI
  • [3] Energy efficiency of selected OECD countries: A slacks based model with undesirable outputs
    Apergis, Nicholas
    Aye, Goodness C.
    Barros, Carlos Pestana
    Gupta, Rangan
    Wanke, Peter
    [J]. ENERGY ECONOMICS, 2015, 51 : 45 - 53
  • [4] Energy audit, an approach to apply the concept of green building for a building in Jordan
    Hassouneh, K.
    Al-Salaymeh, A.
    Qoussous, J.
    [J]. SUSTAINABLE CITIES AND SOCIETY, 2015, 14 : 456 - 462
  • [5] A study of energy performance and efficiency improvement procedures of Government Offices in Hong Kong Special Administrative Region
    Li, Jojo S. M.
    [J]. ENERGY AND BUILDINGS, 2008, 40 (10) : 1872 - 1875
  • [6] Preliminary energy audit of the historical building of the School of Engineering and Architecture of Bologna
    Marinosci, Cosimo
    Morini, Gian Luca
    Semprini, Giovanni
    Garai, Massimo
    [J]. 69TH CONFERENCE OF THE ITALIAN THERMAL ENGINEERING ASSOCIATION, ATI 2014, 2015, 81 : 64 - 73
  • [7] Mills E, 2004, LBNL56637
  • [8] Rahman M, 2008, BUILDING ENERGY CONS
  • [9] Energy conservation measures in an institutional building in sub-tropical climate in Australia
    Rahman, M. M.
    Rasul, M. G.
    Khan, M. M. K.
    [J]. APPLIED ENERGY, 2010, 87 (10) : 2994 - 3004
  • [10] Auditing and analysis of energy consumption of an educational building in hot and humid area
    Sait, Hani Hussain
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2013, 66 : 143 - 152