High Diagnostic Value of 18F-FDG PET/CT in Endometrial Cancer: Systematic Review and Meta-Analysis of the Literature

被引:89
作者
Bollineni, Vikram Rao [1 ,2 ]
Ytre-Hauge, Sigmund [3 ,4 ]
Bollineni-Balabay, Oksana [5 ]
Salvesen, Helga Birgitte [1 ,2 ]
Haldorsen, Ingfrid Salvesen [3 ,4 ]
机构
[1] Haukeland Hosp, Dept Obstet & Gynecol, N-5021 Bergen, Norway
[2] Univ Bergen, Dept Clin Sci, Ctr Canc Biomarkers, Bergen, Norway
[3] Haukeland Hosp, Dept Radiol, N-5021 Bergen, Norway
[4] Univ Bergen, Dept Clin Med, Bergen, Norway
[5] Maastricht Univ, Sch Business & Econ, Dept Quantitat Econ, NL-6200 MD Maastricht, Netherlands
关键词
endometrial cancer; FDG; PET and CT; LYMPH-NODE METASTASIS; POSITRON-EMISSION-TOMOGRAPHY; PROGNOSTIC-SIGNIFICANCE; FDG-PET/CT; COMPUTED-TOMOGRAPHY; CLINICAL IMPACT; CARCINOMA; SUVMAX; TUMOR; MRI;
D O I
10.2967/jnumed.115.170597
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to evaluate the diagnostic performance of F-18-FDG PET/CT for the preoperative assessment of lymph node metastases (LNM) in endometrial cancer patients and for the assessment of endometrial cancer recurrence (ECR) after primary surgical treatment. Methods: A comprehensive search was performed on Pubmed/MEDLINE databases for studies reporting the diagnostic performance of F-18-FDG PET/CT for assessment of LNM and ECR published up to August 15, 2015. Twenty-one studies (13 for LNM and 8 for ECR) were included in the systematic review and meta-analysis. Pooled estimates of sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio of the F-18-FDG PET/CT were calculated along with 95% confidence intervals (Cis). A summary receiver-operating-characteristics curve (SROC) was constructed, and the area under the SROC curve (AUC) was determined along with Q* index. Results: The overall pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, and AUC (with 95% CI) of F-18-FDG PET/CT for detection of LNM were 0.72 (95% CI, 0.63-0.80), 0.94 (95% CI, 0.93-0.96), 10.9 (95% CI, 7.9-15.1), 0.36 (95% CI, 0.27-0.48), 39.7 (95% CI, 21.4-73.6), and 0.94 (95% CI, 0.85-0.99), respectively, whereas the corresponding numbers for detection of ECR were 0.95 (95% CI, 0.91-0.98), 0.91 (95% CI, 0.86-0.94), 8.8 (95% CI, 6.0-12.7), 0.08 (95% CI, 0.05-0.15), 171.7 (95% CI, 67.9-434.3), and 0.97 (95% CI, 0.95-0.98), respectively. The overall diagnostic accuracy (Q* index) in LNM and ECR were 0.88 and 0.93, respectively. Conclusion: F-18-FDG PET/CT has an excellent diagnostic performance for detecting LNM preoperatively and disease recurrence postoperatively in endometrial cancer patients.
引用
收藏
页码:879 / 885
页数:7
相关论文
共 47 条
  • [1] Endometrial cancer
    Amant, F
    Moerman, P
    Neven, P
    Timmerman, D
    Van Limbergen, E
    Vergote, I
    [J]. LANCET, 2005, 366 (9484) : 491 - 505
  • [2] PET/CT in Gynecologic Cancer: Present Applications and Future Prospects-A Clinician's Perspective
    Amit, Amnon
    Schink, Julian
    Reiss, Ari
    Lowenstein, Lior
    [J]. OBSTETRICS AND GYNECOLOGY CLINICS OF NORTH AMERICA, 2011, 38 (01) : 1 - +
  • [3] SUVmax of 18FDG PET/CT as a predictor of high-risk endometrial cancer patients
    Antonsen, Sofie Leisby
    Loft, Annika
    Fisker, Rune
    Nielsen, Anne Lerberg
    Andersen, Erik Sogaard
    Hogdall, Estrid
    Tabor, Ann
    Jochumsen, Kirsten
    Fago-Olsen, Carsten L.
    Asmussen, Jon
    Berthelsen, Anne Kiil
    Christensen, Ib Jarle
    Hogdall, Claus
    [J]. GYNECOLOGIC ONCOLOGY, 2013, 129 (02) : 298 - 303
  • [4] The role of MRI in the conservative management of endometrial cancer
    Ben-Shachar, I
    Vitellas, KM
    Cohn, DE
    [J]. GYNECOLOGIC ONCOLOGY, 2004, 93 (01) : 233 - 237
  • [5] Boonya-ussadorn Trirat, 2014, Journal of the Medical Association of Thailand, V97, pS115
  • [6] BORONOW RC, 1984, OBSTET GYNECOL, V63, P825
  • [7] The clinical impact of [18F]FDG PET/CT for the management of recurrent endometrial cancer:: correlation with clinical and histological findings
    Chung, Hyun Hoon
    Kang, Won Jun
    Kim, Jae Weon
    Park, Noh-Hyun
    Song, Yong-Sang
    Chung, June-Key
    Kang, Soon-Beom
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (06) : 1081 - 1088
  • [8] Preoperative PET/CT standardized FDG uptake values of pelvic lymph nodes as a significant prognostic factor in patients with endometrial cancer
    Chung, Hyun Hoon
    Cheon, Gi Jeong
    Kim, Hee Seung
    Kim, Jae Weon
    Park, Noh-Hyun
    Song, Yong Sang
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 (09) : 1793 - 1799
  • [9] Computed tomography in endometrial carcinoma
    Connor, JP
    Andrews, JI
    Anderson, B
    Buller, RE
    [J]. OBSTETRICS AND GYNECOLOGY, 2000, 95 (05) : 692 - 696
  • [10] Tailoring systematic lymphadenectomy in high-risk clinical early stage endometrial cancer: The role of 18F-FDG PET/CT
    Crivellaro, Cinzia
    Signorelli, Mauro
    Guerra, Luca
    De Ponti, Elena
    Pirovano, Cecilia
    Fruscio, Robert
    Elisei, Federica
    Montanelli, Luca
    Buda, Alessandro
    Messa, Cristina
    [J]. GYNECOLOGIC ONCOLOGY, 2013, 130 (02) : 306 - 311