Peaks in capillary zone electrophoresis: Fact or fiction

被引:0
作者
Beckers, J
Bocek, P
机构
[1] Acad Sci Czech Republ, Inst Analyt Chem, CS-61142 Brno, Czech Republic
[2] Eindhoven Univ Technol, Instrumental Anal Lab, NL-5600 MB Eindhoven, Netherlands
关键词
system peak; capillary zone electrophoresis;
D O I
10.1002/(SICI)1522-2683(19990301)20:3<518::AID-ELPS518>3.3.CO;2-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Non-steady-state electrophoretic processes can be estimated by a repeated application of a steady-state model based on the electroneutrality equation, the modified version of Ohm's law, and the mass balances of the co- and counterions. With such a mathematical model, all parameters in sample zones in capillary zone electrophoresis (CZE) can be calculated. The relationships between the calculated parameters for sample zones in CZE, such as the pH, concentrations of co- and counterions, and the ratio E(1)m(1)/E(2)m(2) versus the mobilities of both anionic and cationic analytes can be visualized in a SystChart, a set of eight panels, for a given background electrolyte (BGE). All properties of a zone, such as the fronting/tailing character and the question of peaks/dips can be read from such a SystChart. Applying n colons, n-1 discontinuities are present in such a SystChart, indicating the presence of system peaks applying that BGE. For BGEs with one colon, no system peaks (discontinuities) exist at moderate pH values. SystCharts calculated for BGEs with a low pH do show discontinuities, however, which indicates that system peaks are present in electropherograms applying BGEs at low pH. Experimentally, it is shown that system peaks are indeed present in electropherograms applying BGEs with one colon at low pH and the mobilities of the system peaks generally increase with decreasing pH. Hydrogen ions seem to act as a second coionic species. Of course, these system peaks are only visible in the UV signal if the BGE has UV-absorbing properties.
引用
收藏
页码:518 / 524
页数:7
相关论文
共 15 条
[1]   QUANTITATIVE-ANALYSIS IN CAPILLARY ZONE ELECTROPHORESIS WITH CONDUCTIVITY AND INDIRECT UV DETECTION [J].
ACKERMANS, MT ;
EVERAERTS, FM ;
BECKERS, JL .
JOURNAL OF CHROMATOGRAPHY, 1991, 549 (1-2) :345-355
[2]   CALCULATION OF THE COMPOSITION OF SAMPLE ZONES IN CAPILLARY ZONE ELECTROPHORESIS .1. MATHEMATICAL-MODEL [J].
BECKERS, JL .
JOURNAL OF CHROMATOGRAPHY A, 1995, 693 (02) :347-357
[3]   Calculation of the composition of sample zones in capillary zone electrophoresis .4. Weak acids and system characteristics [J].
Beckers, JL .
JOURNAL OF CHROMATOGRAPHY A, 1997, 764 (01) :111-126
[4]   System peaks in capillary zone electrophoresis - What are they and where are they coming from? [J].
Beckers, JL ;
Everaerts, FM .
JOURNAL OF CHROMATOGRAPHY A, 1997, 787 (1-2) :235-242
[5]   SYSTEM PEAKS AND DISTURBANCES TO THE BASE-LINE UV SIGNAL IN CAPILLARY ZONE ELECTROPHORESIS [J].
BECKERS, JL .
JOURNAL OF CHROMATOGRAPHY A, 1994, 662 (01) :153-166
[6]   CALCULATION OF THE COMPOSITION OF SAMPLE ZONES IN CAPILLARY ZONE ELECTROPHORESIS .2. SIMULATED ELECTROPHEROGRAMS [J].
BECKERS, JL .
JOURNAL OF CHROMATOGRAPHY A, 1995, 696 (02) :285-294
[7]   Calculation of the composition of sample zones in capillary zone electrophoresis .3. Weak bases and the application of background electrolytes with two co-ions [J].
Beckers, JL .
JOURNAL OF CHROMATOGRAPHY A, 1996, 741 (02) :265-277
[8]   INDIRECT FLUORIMETRIC DETECTION AND QUANTIFICATION IN CAPILLARY ZONE ELECTROPHORESIS OF INORGANIC ANIONS AND NUCLEOTIDES [J].
GROSS, L ;
YEUNG, ES .
JOURNAL OF CHROMATOGRAPHY, 1989, 480 :169-178
[9]   System peaks in capillary zone electrophoresis .3. Practical rules for predicting the existence of system peaks in capillary zone electrophoresis of anions using indirect spectrophotometric detection [J].
Macka, M ;
Haddad, PR ;
Gebauer, P ;
Bocek, P .
ELECTROPHORESIS, 1997, 18 (11) :1998-2007
[10]   Concentration distributions in capillary zone electrophoresis: CZE in a spreadsheet [J].
Mikkers, FEP .
ANALYTICAL CHEMISTRY, 1999, 71 (02) :522-533