Development and evaluation of high throughput functional assay methods for hERG potassium channel

被引:61
作者
Tang, WM
Kang, JS
Wu, XY
Rampe, D
Wang, L
Shen, H
Li, ZY
Dunnington, D
Garyantes, T
机构
[1] Aventis Pharmaceut, Dept Profiling & High Screening, Bridgewater, NJ 08807 USA
[2] Aventis Pharmaceut, Dept Safety Pharmacol, Bridgewater, NJ 08807 USA
[3] Aventis Pharmaceut, Dept Analyt Chem, Bridgewater, NJ 08807 USA
关键词
D O I
10.1177/108705710100600506
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Three functional hERG channel assay methods have been developed and evaluated. The methods were tested against five known hERG channel inhibitors: dofetilide, terfenadine (Seldane), sertindole (Serdolect), astemizole (Hismanal), and cisapride (Propulsid). The DiBAC(4)(3)-based assays were found to be the most economical but had high false-hit rates as a result of the interaction of dye with the test compounds. The membrane potential dye assay had fewer color-quenching problems but was expensive and still gave false hits. The nonradioactive Rb+ efflux assay was the most sensitive of all the assays evaluated and had the lowest false-hit rate.
引用
收藏
页码:325 / 331
页数:7
相关论文
共 28 条
[1]   Effects of fluoroquinolones on HERG currents [J].
Bischoff, U ;
Schmidt, C ;
Netzer, R ;
Pongs, O .
EUROPEAN JOURNAL OF PHARMACOLOGY, 2000, 406 (03) :341-343
[2]   A MOLECULAR-BASIS FOR CARDIAC-ARRHYTHMIA - HERG MUTATIONS CAUSE LONG QT SYNDROME [J].
CURRAN, ME ;
SPLAWSKI, I ;
TIMOTHY, KW ;
VINCENT, GM ;
GREEN, ED ;
KEATING, MT .
CELL, 1995, 80 (05) :795-803
[3]   HTS approaches to voltage-gated ion channel drug discovery [J].
Denyer, J ;
Worley, J ;
Cox, B ;
Allenby, G ;
Banks, M .
DRUG DISCOVERY TODAY, 1998, 3 (07) :323-332
[4]  
*EMEA EUR AG EV ME, 1997, POINTS CONS ASS POT, P986
[5]   Molecular determinants of dofetilide block of HERG K+ channels [J].
Ficker, E ;
Jarolimek, W ;
Kiehn, J ;
Baumann, A ;
Brown, AM .
CIRCULATION RESEARCH, 1998, 82 (03) :386-395
[6]   VOLTAGE-SENSITIVE FLUORESCENCE OF AMPHIPHILIC HEMICYANINE DYES IN NEURON MEMBRANE [J].
FROMHERZ, P ;
MULLER, CO .
BIOCHIMICA ET BIOPHYSICA ACTA, 1993, 1150 (02) :111-122
[7]   Cell-based assays and instrumentation for screening ion-channel targets [J].
Gonzalez, JE ;
Oades, K ;
Leychkis, Y ;
Harootunian, A ;
Negulescu, PA .
DRUG DISCOVERY TODAY, 1999, 4 (09) :431-439
[8]   Improved indicators of cell membrane potential that use fluorescence resonance energy transfer [J].
Gonzalez, JE ;
Tsien, RY .
CHEMISTRY & BIOLOGY, 1997, 4 (04) :269-277
[9]   VOLTAGE SENSING BY FLUORESCENCE RESONANCE ENERGY-TRANSFER IN SINGLE CELLS [J].
GONZALEZ, JE ;
TSIEN, RY .
BIOPHYSICAL JOURNAL, 1995, 69 (04) :1272-1280
[10]  
HAMILL OP, 1983, PFLUG ARCH EUR J PHY, V391, P85