Evaluation of an empirical monitor output estimation in carbon ion radiotherapy

被引:1
作者
Matsumura, Akihiko [1 ]
Yusa, Ken [1 ]
Kanai, Tatsuaki [1 ]
Mizota, Manabu [2 ]
Ohno, Tatsuya [1 ]
Nakano, Takashi [1 ]
机构
[1] Gunma Univ, Gunma Univ Heavy Ion Med Ctr, Maebashi, Gunma 3718511, Japan
[2] Natl Inst Radiol Sci, Res Ctr Charged Particle Therapy, Chiba 2638555, Japan
关键词
carbon ion radiotherapy; monitor units; field effect; BRAGG PEAK FIELDS; IRRADIATION SYSTEM; UNIT CALCULATIONS; THERAPY; RANGE; BEAMS; DESIGN; HIMAC;
D O I
10.1118/1.4928145
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: A conventional broad beam method is applied to carbon ion radiotherapy at Gunma University Heavy Ion Medical Center. According to this method, accelerated carbon ions are scattered by various beam line devices to form 3D dose distribution. The physical dose per monitor unit (d/MU) at the isocenter, therefore, depends on beam line parameters and should be calibrated by a measurement in clinical practice. This study aims to develop a calculation algorithm for d/MU using beam line parameters. Methods: Two major factors, the range shifter dependence and the field aperture effect, are measured via PinPoint chamber in a water phantom, which is an identical setup as that used for monitor calibration in clinical practice. An empirical monitor calibration method based on measurement results is developed using a simple algorithm utilizing a linear function and a double Gaussian pencil beam distribution to express the range shifter dependence and the field aperture effect. Results: The range shifter dependence and the field aperture effect are evaluated to have errors of 0.2% and 0.5%, respectively. The proposed method has successfully estimated d/MU with a difference of less than 1% with respect to the measurement results. Taking the measurement deviation of about 0.3% into account, this result is sufficiently accurate for clinical applications. Conclusions: An empirical procedure to estimate d/MU with a simple algorithm is established in this research. This procedure allows them to use the beam time for more treatments, quality assurances, and other research endeavors. (C) 2015 American Association of Physicists in Medicine.
引用
收藏
页码:5188 / 5194
页数:7
相关论文
共 18 条
  • [1] Scatter factors in proton therapy with a broad beam
    Akagi, T
    Kanematsu, N
    Takatani, Y
    Sakamoto, H
    Hishikawa, Y
    Abe, M
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (07) : 1919 - 1928
  • [2] Range and modulation dependencies for proton beam dose per monitor unit calculations
    Hsi, Wen C.
    Schreuder, Andries N.
    Moyers, Michael F.
    Allgower, Chris E.
    Farr, Jonathan B.
    Mascia, Anthony E.
    [J]. MEDICAL PHYSICS, 2009, 36 (02) : 634 - 641
  • [3] Field-size effect of physical doses in carbon-ion scanning using range shifter plates
    Inaniwa, Taku
    Furukawa, Takuji
    Nagano, Ai
    Sato, Shinji
    Saotome, Naoya
    Noda, Koji
    Kanai, Tatsuaki
    [J]. MEDICAL PHYSICS, 2009, 36 (07) : 2889 - 2897
  • [4] Irradiation of mixed beam and design of spread-out Bragg peak for heavy-ion radiotherapy
    Kanai, T
    Furusawa, Y
    Fukutsu, K
    Itsukaichi, H
    EguchiKasai, K
    Ohara, H
    [J]. RADIATION RESEARCH, 1997, 147 (01) : 78 - 85
  • [5] Biophysical characteristics of HIMAC clinical irradiation system for heavy-ion radiation therapy
    Kanai, T
    Endo, M
    Minohara, S
    Miyahara, N
    Koyama-Ito, H
    Tomura, H
    Matsufuji, N
    Futami, Y
    Fukumura, A
    Hiraoka, T
    Furusawa, Y
    Ando, K
    Suzuki, M
    Soga, F
    Kawachi, K
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 44 (01): : 201 - 210
  • [6] The prediction of output factors for spread-out proton Bragg peak fields in clinical practice
    Kooy, HM
    Rosenthal, SJ
    Engelsman, M
    Mazal, A
    Slopsema, RL
    Paganetti, H
    Flanz, JB
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (24) : 5847 - 5856
  • [7] Monitor unit calculations for range-modulated spread-out Bragg peak fields
    Kooy, HM
    Schaefer, M
    Rosenthal, S
    Bortfeld, T
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (17) : 2797 - 2808
  • [8] Field-size dependence of doses of therapeutic carbon beams
    Kusano, Yohsuke
    Kanai, Tatsuaki
    Yonai, Shunsuke
    Komori, Masataka
    Ikeda, Noritoshi
    Tachikawa, Yuji
    Ito, Atsushi
    Uchida, Hirohisa
    [J]. MEDICAL PHYSICS, 2007, 34 (10) : 4016 - 4022
  • [9] Implementation of an improved dose-per-MU model for double-scattered proton beams to address interbeamline modulation width variability
    Lin, Liyong
    Shen, JiaJien
    Ainsley, Christopher G.
    Solberg, Timothy D.
    McDonough, James E.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (03): : 297 - 306
  • [10] Mizota M., 2012, JPN J MED PHYS S3, V32, P93