Suture versus screw fixation of displaced tibial eminence fractures: A biomechanical comparison

被引:89
作者
Bong, MR [1 ]
Romero, A [1 ]
Kubiak, E [1 ]
Iesaka, K [1 ]
Heywood, CS [1 ]
Kummer, F [1 ]
Rosen, J [1 ]
Jazrawi, L [1 ]
机构
[1] NYU, Hosp Joint Dis, Dept Orthopaed, New York, NY 10003 USA
关键词
tibial eminence fracture; displaced; screw fixation; suture fixation; biomechanics;
D O I
10.1016/j.arthro.2005.06.019
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: Classification and treatment of fibial eminence fractures are determined by the degree of fragment displacement. A variety of surgical procedures have been proposed to stabilize displaced fractures using both open and arthroscopic techniques. Two common fixation techniques involve use of cannulated screws and sutures tied over an anterior tibial bone bridge. We are unaware of any biomechanical studies that have compared the strength of various techniques of fixation. Type of Study: Biomechanical study in a cadaveric model. Methods: Seven matched pairs of fresh-frozen human cadaveric knees were stripped of all soft tissue except the anterior cruciate ligament (ACL). Simulated type III tibial eminence fractures were created using an osteotome. Fragments of each matched pair were randomized to fixation with either a single 4-mm cannulated cancellous screw with a washer or an arthroscopic suture technique using 3 No. 2 Fiberwire sutures (Arthrex, Naples, FL) passed through the tibial base of the ACL and tied over bone tunnels on the anterior tibial cortex. Specimens were then loaded with a constant load rate of 20 mm/min, and load-deformation curves were generated. The ultimate strength and stiffness were computed for each curve. The failure mode for each test was observed. A paired 2-tailed t test was used to determine the statistically significant difference between the two methods. Results: Specimens fixed with Fiberwire had a mean ultimate strength of 319 N with a standard deviation of 125 N. Those fixed with cannulated screws had a mean ultimate strength of 125 N with a standard deviation of 74 N. This difference was statistically significant (P = .0038). There was no significant difference between the mean stiffness of Fiberwire constructs (63 N; SD, 50 N) and the mean stiffness of the cannulated screw constructs (20 N; SD, 32 N). The failure modes of the Fiberwire constructs included 1 ACL failure, 3 failures of suture cutting through the anterior fibial cortex, and 3 of suture cutting through the tibial eminence fragment. The single mode of failure for the cannulated screw constructs was screw pullout of cancellous bone. Conclusions: The initial ultimate strength of Fiberwire fixation of tibial eminence fractures in these specimens was significantly stronger than that of cannulated screw fixation. Clinical Relevance: It appears that Fiberwire fixation of eminence fractures provides biomechanical advantages over cannulated screw fixation and may influence the type of treatment one chooses for patients with tibial eminence fractures.
引用
收藏
页码:1172 / 1176
页数:5
相关论文
共 28 条
[1]   Tibial intercondylar eminence fractures in adults: arthroscopic treatment [J].
Delcogliano, A ;
Chiossi, S ;
Caporaso, A ;
Menghi, A ;
Rinonapoli, G .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2003, 11 (04) :255-259
[2]  
GEISSLER WB, 1993, ORTHOPEDICS, V16, P331
[3]   AVULSION FRACTURE OF THE TIBIAL EMINENCE ASSOCIATED WITH SEVERE MEDIAL LIGAMENTOUS INJURY IN AN ADOLESCENT - A CASE-REPORT AND LITERATURE-REVIEW [J].
HAYES, JM ;
MASEAR, VR .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1984, 12 (04) :330-333
[4]   A new method for arthroscopic treatment of tibial eminence fractures with eyed Steinmann pins [J].
Jung, YB ;
Yum, JK ;
Koo, BH .
ARTHROSCOPY, 1999, 15 (06) :672-675
[5]   FRACTURE OF THE TIBIAL SPINE IN ADULTS AND CHILDREN - A REVIEW OF 31 CASES [J].
KENDALL, NS ;
HSU, SYC ;
CHAN, KM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (06) :848-852
[6]   NONUNION OF INTERCONDYLAR EMINENCE FRACTURE OF THE TIBIA [J].
KEYS, GW ;
WALTERS, J .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1988, 28 (06) :870-871
[7]   ARTHROSCOPIC REDUCTION AND FIXATION OF A COMPLETELY DISPLACED FRACTURE OF THE INTERCONDYLAR EMINENCE OF THE TIBIA [J].
KOBAYASHI, S ;
TERAYAMA, K .
ARTHROSCOPY, 1994, 10 (02) :231-235
[8]   Tibial eminence fractures in children: Prevalence of meniscal entrapment [J].
Kocher, MS ;
Micheli, LJ ;
Gerbino, P ;
Hresko, MT .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2003, 31 (03) :404-407
[9]   Technique for arthroscopic suture fixation of displaced tibial intercondylar eminence fractures [J].
Kogan, MG ;
Marks, P ;
Amendola, A .
ARTHROSCOPY, 1997, 13 (03) :301-306
[10]   Arthroscopic surgery for partial rotator cuff tears [J].
Lehman, RC ;
Perry, CR .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2003, 19 (07) :e81-e84