Analysis of steady state thermal-hydraulic behaviour of the DEMO divertor cassette body cooling circuit

被引:11
作者
Di Maio, P. A. [1 ]
Garitta, S. [1 ]
You, J. H. [2 ]
Mazzone, G. [3 ]
Vallone, E. [1 ]
机构
[1] Univ Palermo, Vials Sci,Edificio 6, I-90128 Palermo, Italy
[2] Max Planck Inst Plasma Phys E2 M, Boltzmann Str 2, D-85748 Garching, Germany
[3] ENEA CR Frascati, Dept Fus & Technol Nucl Safety & Secur, Via E Fermi 45, I-00044 Rome, Italy
关键词
DEMO; Divertor; Cassette body; CFD analysis; Thermofluid-dynamics; SYSTEM;
D O I
10.1016/j.fusengdes.2017.02.012
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Within the framework of the Work Package DIV 1 - "Divertor Cassette Design and Integration" of the EUROfusion action, a research campaign has been jointly carried out by ENEA and University of Palermo to investigate the thermal-hydraulic performances of the DEMO divertor cassette cooling system. A comparative evaluation study has been perforrned considering the two different options under consideration for the divertor cassette body coolant, namely subcooled pressurized water and helium. The research activity has been carried out following a theoretical-computational approach based on the finite volume method and adopting a qualified Computational Fluid-Dynamic (CFD) code. CFD analyses have been carried out for the considered options of cassette body cooling circuit under nominal steady state conditions and the pertaining thermal-hydraulic performances have been assessed In terms of overall coolant thermal rise, coolant total pressure drop, flow velocity and pumping power, to check whether they comply with the corresponding limits. Results obtained are reported and critically discussed. (C) 2017 The Authors. Published by Elsevier B.V.
引用
收藏
页码:437 / 441
页数:5
相关论文
共 7 条
[1]  
[Anonymous], EFDAD2MY45W IDM
[2]   On the hydraulic behaviour of ITER Shield Blocks #14 and #08. Computational analysis and comparison with experimental tests [J].
Di Maio, P. A. ;
Merola, M. ;
Mitteau, R. ;
Raffray, R. ;
Vallone, E. .
FUSION ENGINEERING AND DESIGN, 2016, 109 :30-36
[3]   Numerical simulation of the transient thermal-hydraulic behaviour of the ITER blanket cooling system under the draining operational procedure [J].
Di Maio, P. A. ;
Dell'Orco, G. ;
Furmanek, A. ;
Garitta, S. ;
Merola, M. ;
Mitteau, R. ;
Raffray, R. ;
Spagnuolo, G. A. ;
Vallone, E. .
FUSION ENGINEERING AND DESIGN, 2015, 98-99 :1664-1667
[4]   Analysis of the steady state hydraulic behaviour of the ITER blanket cooling system [J].
Di Maio, P. A. ;
Dell'Orco, G. ;
Furmanek, A. ;
Garitta, S. ;
Merola, M. ;
Mitteau, R. ;
Raffray, R. ;
Spagnuolo, G. A. ;
Vallone, E. .
FUSION ENGINEERING AND DESIGN, 2015, 98-99 :1470-1473
[5]  
Romanelli F., 2012, FUSION ELECT ROADMAP
[6]   Conceptual design studies for the European DEMO divertor: Rationale and first results [J].
You, J. H. ;
Mazzone, G. ;
Visca, E. ;
Bachmann, Ch ;
Autissier, E. ;
Barrett, T. ;
Cocilovo, V. ;
Crescenzi, F. ;
Domalapally, P. K. ;
Dongiovanni, D. ;
Entler, S. ;
Federici, G. ;
Frosi, P. ;
Fursdon, M. ;
Greuner, H. ;
Hancock, D. ;
Marzullo, D. ;
McIntosh, S. ;
Mueller, A. V. ;
Porfiri, M. T. ;
Ramogida, G. ;
Reiser, J. ;
Richou, M. ;
Rieth, M. ;
Rydzy, A. ;
Villari, R. ;
Widak, V. .
FUSION ENGINEERING AND DESIGN, 2016, 109 :1598-1603
[7]  
You J.H., 2017, NUCL MAT EN IN PRESS