Real-time label-free affinity biosensors for enumeration of total bacteria based on immobilized concanavalin A

被引:10
|
作者
Jantra, Jongjit [2 ,3 ,4 ]
Kanatharana, Proespichaya [2 ,3 ,4 ]
Asawatreratanakul, Punnee [2 ,5 ]
Hedstroem, Martin [6 ]
Mattiasson, Bo [6 ]
Thavarungkul, Panote [1 ,2 ,3 ]
机构
[1] Prince Songkla Univ, Fac Sci, Dept Phys, Hat Yai 90112, Songkhla, Thailand
[2] Prince Songkla Univ, Trace Anal & Biosensor Res Ctr, Hat Yai 90112, Songkhla, Thailand
[3] Prince Songkla Univ, Fac Sci, Ctr Innovat Chem, Hat Yai 90112, Songkhla, Thailand
[4] Prince Songkla Univ, Fac Sci, Dept Chem, Hat Yai 90112, Songkhla, Thailand
[5] Prince Songkla Univ, Fac Sci, Dept Biochem, Hat Yai 90112, Songkhla, Thailand
[6] Lund Univ, Dept Biotechnol, Ctr Chem & Chem Engn, Lund, Sweden
来源
JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING | 2011年 / 46卷 / 13期
关键词
Bacteria; surface plasmon resonance; impedance; biosensor; high sensitivity; real-time; CARBOHYDRATE INTERACTION; INTERFERON-GAMMA; LECTIN; SURFACE; COLI; IDENTIFICATION; RECOGNITION; IMMUNOSENSOR; SALMONELLA; ANTIBODY;
D O I
10.1080/10934529.2011.609022
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This work presents the results of the use of flow injection surface plasmon resonance and impedimetric affinity biosensors for detecting and enumerating total bacteria based on the binding between E. coli and Con A, immobilized on amodified gold electrode. The single analysis time for both techniques was less than 20 min. Dissociation between the immobilized Con A and the E. coli using 200 mM of glucose in HClt at pH of 2.00 enabling the sensor to be reused for between 29-35 times. Impedimetric detection provided a much lower limit of detection (12 CFU mL(-1)) than the surface plasmon resonance method (6.1 x 10(7) CFU mL(-1)). Using the impedimetric system, real sample analysis was performed and the results were compared to the plate count agar method. Cell concentrations obtained by the biosensor were only slightly different from the result obtained from the plate count agar. The proposed system offers a rapid and useful tool for screening detection and enumeration of total bacteria.
引用
收藏
页码:1450 / 1460
页数:11
相关论文
共 50 条
  • [21] New Generation of Ultrasensitive Label-Free Optical Si Nanowire-Based Biosensors
    Irrera, Alessia
    Leonardi, Antonio Alessio
    Di Franco, Cinzia
    Lo Faro, Maria Jose
    Palazzo, Gerardo
    D'Andrea, Cristiano
    Manoli, Kyriaki
    Franzo, Giorgia
    Musumeci, Paolo
    Fazio, Barbara
    Torsi, Luisa
    Priolo, Francesco
    ACS PHOTONICS, 2018, 5 (02): : 471 - 479
  • [22] Real-Time Label-Free Impedimetric Protein Detection Using Interdigitated Gold Microelectrodes and Flow Injection Analysis
    Eletxigerra, Unai
    Martinez-Perdiguero, Josu
    Juarros, Aritz
    Bayon, Raquel
    Merino, Santos
    26TH EUROPEAN CONFERENCE ON SOLID-STATE TRANSDUCERS, EUROSENSOR 2012, 2012, 47 : 1390 - 1393
  • [23] Label-Free Real-Time Detection of DNA Methylation Based on Quartz Crystal Microbalance Measurement
    Wang, Jie
    Zhu, Zhiqiang
    Ma, Hongwei
    ANALYTICAL CHEMISTRY, 2013, 85 (04) : 2096 - 2101
  • [24] Real-time and label-free analyte detection in a flow-through mode using immobilized fluorescent aptamer/quantum dots molecular switches
    Bogomolova, Anastasia
    Aldissi, Matt
    BIOSENSORS & BIOELECTRONICS, 2015, 66 : 290 - 296
  • [25] The mesoscopic effect on label-free biosensors based on localized surface plasmon resonance of immobilized colloidal gold
    Yamamichi, Junta
    Iida, Mie
    Ojima, Tetsunori
    Handa, Yoichiro
    Yamada, Tomohiro
    Kuroda, Ryo
    Imamura, Takeshi
    Yano, Tetsuya
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 143 (01): : 349 - 356
  • [26] Real-Time Label-Free Direct Electronic Monitoring of Topoisomerase Enzyme Binding Kinetics on Graphene
    Zuccaro, Laura
    Tesauro, Cinzia
    Kurkina, Tetiana
    Fiorani, Paola
    Yu, Hak Ki
    Knudsen, Birgitta R.
    Kern, Klaus
    Desideri, Alessandro
    Balasubramanian, Kannan
    ACS NANO, 2015, 9 (11) : 11166 - 11176
  • [27] Surface plasmon resonance fiber sensor for real-time and label-free monitoring of cellular behavior
    Shevchenko, Yanina
    Camci-Unal, Gulden
    Cuttica, Davide E.
    Dokmeci, Mehmet R.
    Albert, Jacques
    Khademhosseini, Ali
    BIOSENSORS & BIOELECTRONICS, 2014, 56 : 359 - 367
  • [28] Label-free detection of pathogenic bacteria via immobilized antimicrobial peptides
    Dong, Zong-Mu
    Zhao, Guang-Chao
    TALANTA, 2015, 137 : 55 - 61
  • [29] Real time and label-free analysis of cellular activity on chip
    Milgam, S.
    Livache, T.
    Roupioz, Y.
    Cortes, S.
    Villiers, M-B.
    Marche, P. N.
    2009 IEEE SENSORS, VOLS 1-3, 2009, : 1769 - +
  • [30] Real-time and label-free detection of chloramphenicol residues with specific molecular interaction
    Dong, Z.
    Huang, G.
    Xu, S.
    Deng, C.
    Zhu, J.
    Chen, S.
    Yang, X.
    Zhao, S.
    JOURNAL OF MICROSCOPY, 2009, 234 (03) : 255 - 261