Real-time label-free affinity biosensors for enumeration of total bacteria based on immobilized concanavalin A

被引:10
|
作者
Jantra, Jongjit [2 ,3 ,4 ]
Kanatharana, Proespichaya [2 ,3 ,4 ]
Asawatreratanakul, Punnee [2 ,5 ]
Hedstroem, Martin [6 ]
Mattiasson, Bo [6 ]
Thavarungkul, Panote [1 ,2 ,3 ]
机构
[1] Prince Songkla Univ, Fac Sci, Dept Phys, Hat Yai 90112, Songkhla, Thailand
[2] Prince Songkla Univ, Trace Anal & Biosensor Res Ctr, Hat Yai 90112, Songkhla, Thailand
[3] Prince Songkla Univ, Fac Sci, Ctr Innovat Chem, Hat Yai 90112, Songkhla, Thailand
[4] Prince Songkla Univ, Fac Sci, Dept Chem, Hat Yai 90112, Songkhla, Thailand
[5] Prince Songkla Univ, Fac Sci, Dept Biochem, Hat Yai 90112, Songkhla, Thailand
[6] Lund Univ, Dept Biotechnol, Ctr Chem & Chem Engn, Lund, Sweden
来源
JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING | 2011年 / 46卷 / 13期
关键词
Bacteria; surface plasmon resonance; impedance; biosensor; high sensitivity; real-time; CARBOHYDRATE INTERACTION; INTERFERON-GAMMA; LECTIN; SURFACE; COLI; IDENTIFICATION; RECOGNITION; IMMUNOSENSOR; SALMONELLA; ANTIBODY;
D O I
10.1080/10934529.2011.609022
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This work presents the results of the use of flow injection surface plasmon resonance and impedimetric affinity biosensors for detecting and enumerating total bacteria based on the binding between E. coli and Con A, immobilized on amodified gold electrode. The single analysis time for both techniques was less than 20 min. Dissociation between the immobilized Con A and the E. coli using 200 mM of glucose in HClt at pH of 2.00 enabling the sensor to be reused for between 29-35 times. Impedimetric detection provided a much lower limit of detection (12 CFU mL(-1)) than the surface plasmon resonance method (6.1 x 10(7) CFU mL(-1)). Using the impedimetric system, real sample analysis was performed and the results were compared to the plate count agar method. Cell concentrations obtained by the biosensor were only slightly different from the result obtained from the plate count agar. The proposed system offers a rapid and useful tool for screening detection and enumeration of total bacteria.
引用
收藏
页码:1450 / 1460
页数:11
相关论文
共 50 条
  • [1] Antibody functionalized capacitance sensor for label-free and real-time detection of bacteria and antibiotic susceptibility
    Zeeshan
    Bahrami, Sadra
    Park, Sungsu
    Cho, Sungbo
    TALANTA, 2024, 272
  • [2] Label-free and real-time monitoring of yeast cell growth by the bending of polymer microcantilever biosensors
    Liu, Yifan
    Schweizer, Lilian M.
    Wang, Wenxing
    Reuben, Robert L.
    Schweizer, Michael
    Shu, Wenmiao
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 178 : 621 - 626
  • [3] Label-free detection of Staphylococcus aureus in skin using real-time potentiometric biosensors based on carbon nanotubes and aptamers
    Zelada-Guillen, Gustavo A.
    Luis Sebastian-Avila, Jose
    Blondeau, Pascal
    Riu, Jordi
    Xavier Rius, F.
    BIOSENSORS & BIOELECTRONICS, 2012, 31 (01): : 226 - 232
  • [4] A lectin-coupled porous silicon-based biosensor: label-free optical detection of bacteria in a real-time mode
    Yaghoubi, Mona
    Rahimi, Fereshteh
    Negahdari, Babak
    Rezayan, Ali Hossein
    Shafiekhani, Azizollah
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [5] Nanoplasmonics for Real-Time and Label-Free Monitoring of Microbial Biofilm Formation
    Funari, Riccardo
    Bhalla, Nikhil
    Chu, Kang-Yu
    Soderstrom, Bill
    Shen, Amy Q.
    ACS SENSORS, 2018, 3 (08): : 1499 - 1509
  • [6] Surveilling cellular vital signs: toward label-free biosensors and real-time viability assays for bioprocessing
    Rosenberg, Julian N.
    Cady, Nathaniel C.
    CURRENT OPINION IN BIOTECHNOLOGY, 2021, 71 : 123 - 129
  • [7] Ligands for label-free detection of whole bacteria on biosensors: A review
    Templier, Vincent
    Roux, Agnes
    Roupioz, Yoann
    Livache, Thierry
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2016, 79 : 71 - 79
  • [8] Real-Time Label-Free Monitoring of Nanoparticle Cell Uptake
    Suutari, Teemu
    Silen, Tiina
    Sen Karaman, Didem
    Saari, Heikki
    Desai, Diti
    Kerkela, Erja
    Laitinen, Saara
    Hanzlikova, Martina
    Rosenholm, Jessica M.
    Yliperttula, Marjo
    Viitala, Tapani
    SMALL, 2016, 12 (45) : 6289 - 6300
  • [9] Real-Time, label-free monitorine, of tumor antigen and serum antibody interactions
    Campagnolo, C
    Meyers, KJ
    Ryan, T
    Atkinson, RC
    Chen, YT
    Scanlan, MJ
    Ritter, G
    Old, LJ
    Batt, CA
    JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2004, 61 (03): : 283 - 298
  • [10] Metal Mesh Device Sensor Immobilized with a Trimethoxysilane-Containing Glycopolymer for Label-Free Detection of Proteins and Bacteria
    Seto, Hirokazu
    Kamba, Seiji
    Kondo, Takashi
    Hasegawa, Makoto
    Nashima, Shigeki
    Ehara, Yoshinobu
    Ogawa, Yuichi
    Hoshino, Yu
    Miura, Yoshiko
    ACS APPLIED MATERIALS & INTERFACES, 2014, 6 (15) : 13234 - 13241