摘要
The liquid chromatography-electrospray ionization tandem mass spectrometry method was developed for determination of clenbuterol residues in liver tissue as a regulatory matrix for the control of clenbuterol abuse as an anabolic. To investigate the level of clenbuterol residues during the withdrawal period, male food-producing pigs were exposed to subchronic repeat oral administration of a clenbuterol growth-promoting dose for 28 days. The analytical procedure showed acceptable validation results for all liver spiked samples analyzed and proved to be useful as a quantification and confirmation method in supporting regulatory enforcement programs of clenbuterol misuse monitoring. The highest level of clenbuterol in the liver of treated animals was recorded on day 0 of treatment cessation (21.58 +/- 14.29 ng/g), followed by 6.59 +/- 3.11 ng/g on day 3, 0.83 +/- 0.27 ng/g on day 7, and 0.44 +/- 0.08 ng/g on day 14 of withdrawal. At the end of the study period (day 35), the concentration of clenbuterol was below the method limit of detection (<0.1 ng/g).
引用
收藏
页码:5 / 9
页数:5
相关论文
共 26 条
[1]  
Appelgren LE, 1996, FLEISCHWIRTSCHAFT, V76, P314
[2]  
Brambilla G, 1997, JAMA-J AM MED ASSOC, V278, P635, DOI 10.1001/jama.278.8.635
[3]   Detection and confirmation of beta-agonists in bovine retina using LC/APCI-MS [J].
Doerge, DR ;
Churchwell, MI ;
Holder, CL ;
Rowe, L ;
Bajic, S .
ANALYTICAL CHEMISTRY, 1996, 68 (11) :1918-1923
[4]  
EC, 2002, OFFICIAL J L, VL221, P8
[5]   EFFECTIVE LABORATORY MONITORING FOR THE ABUSE OF THE BETA-AGONIST CLENBUTEROL IN CATTLE [J].
ELLIOTT, CT ;
MCEVOY, JDG ;
MCCAUGHEY, WJ ;
SHORTT, DH ;
CROOKS, SRH .
ANALYST, 1993, 118 (04) :447-448
[6]  
Fesser ACE, 2005, J AOAC INT, V88, P61
[7]  
Garay JB, 1997, REV CLIN ESP, V197, P92
[8]  
Gojmerac T, 2002, FOOD TECHNOL BIOTECH, V40, P343
[9]  
Gojmerac T, 2002, VET HUM TOXICOL, V44, P269
[10]   Quantitative analysis of clenbuterol in meat products using liquid chromatography-electrospray ionisation tandem mass spectrometry [J].
Guy, PA ;
Savoy, MC ;
Stadler, RH .
JOURNAL OF CHROMATOGRAPHY B, 1999, 736 (1-2) :209-219