Assessment of paper spray ionization for quantitation of pharmaceuticals in blood spots

被引:158
作者
Manicke, Nicholas E. [2 ,3 ]
Yang, Qian [1 ,3 ]
Wang, He [1 ,3 ]
Oradu, Sheran [2 ,3 ]
Ouyang, Zheng [1 ,3 ]
Cooks, R. Graham [2 ,3 ]
机构
[1] Purdue Univ, Weldon Sch Biomed Engn, W Lafayette, IN 47907 USA
[2] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
[3] Purdue Univ, Ctr Analyt Instrumentat Dev, W Lafayette, IN 47907 USA
关键词
Direct analysis; Ambient ionization; Biological fluids; Electrospray ionization; Quantitative precision; TANDEM MASS-SPECTROMETRY; PHARMACODYNAMICS; PHARMACOKINETICS; SPECIMENS;
D O I
10.1016/j.ijms.2010.06.037
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Paper spray uses solvent electrospray to produce gas phase ions from samples deposited on paper or other porous media by applying a high voltage to the wet substrate. The method is amenable to the analysis of small and large molecules and is applied here to pharmaceuticals from dried blood spots, making it potentially useful for quantitation of drugs during clinical trials or for therapeutic drug monitoring in a hospital or clinic. Several topics related to the analytical characteristics of paper spray for analyzing drugs in dried blood spots are explored. (1)The effect of protein-drug interactions was studied by comparing the ratio of propranolol (PRN) and atenolol (ATN), two drugs with widely disparate protein binding properties, in water and in blood and by spiking a deuterated analog of PRN into blood already containing PRN and then allowing the blood to incubate for different lengths of time. In the first experiment, the ratio of PRN to ATN was the same in both water and blood. In the second experiment, the ratio of PRN and PRN d7 was the same regardless of how long the deuterated analog was allowed to equilibrate in the blood. These results suggest that protein binding does not affect analyte signal, and that paper spray therefore measures the total drug concentration in blood at least in this case. (2) Alternative methods for incorporation of the isotopically labeled internal standard (IS), which is needed for quantitative results when analyzing drugs in dried blood spots, were tested. Because it is often not feasible to add the standard to the liquid blood at the point of collection, the IS must be incorporated into the dried blood in some way. The IS PRN d7 was combined with dried blood spots containing PRN in three different ways: by pretreating the paper with an IS solution, by doping the IS into the spray solvent, and by adding an IS solution to a punched out section of a DBS. The variance of the method was less than 8% when the IS was added to the paper either before adding the blood or when adding it afterwards to the dried blood punch. The variance was 16% when the IS was added to the solvent eluent. In all cases, the recovery of PRN was lower than that of the IS. (3) Finally, matrix effects were assessed by measuring the signal obtained for PRN d7 in matrices ranging from neat solution, to blank blood, to blood containing 1 mu g/mL of PRN. A neat solution was found to give approximately 10 times higher signal than blood, indicating that suppression of ionization is occurring. The presence of a high concentration of PRN did not affect the response for PRN d7. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:123 / 129
页数:7
相关论文
共 50 条
  • [41] Rapid analysis of Aurantii Fructus Immaturus (Zhishi) using paper spray ionization mass spectrometry
    Liu, Xuemei
    Gu, Zhixin
    Guo, Yuan
    Liu, Jingjing
    Ma, Ming
    Chen, Bo
    Wang, Liping
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 137 : 204 - 212
  • [42] A novel method for quantitation of acylglycines in human dried blood spots by UPLC-tandem mass spectrometry
    Fisher, Lawrence
    Davies, Christine
    Al-Dirbashi, Osama Y.
    ten Brink, Herman J.
    Chakraborty, Pranesh
    Lepage, Nathalie
    CLINICAL BIOCHEMISTRY, 2018, 54 : 131 - 138
  • [43] Rapid screening of high-priority N-nitrosamines in pharmaceutical, forensic, and environmental samples with paper spray ionization and filter cone spray ionization-mass spectrometry
    McDaniel, Trevor J.
    Holtz, Jessica M.
    Bondzie, Ebenezer H.
    Overfelt, Makoy
    Fedick, Patrick W.
    Mulligan, Christopher C.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2023, 37 (S1)
  • [44] Simultaneous determination of cocaine and opiates in dried blood spots by electrospray ionization tandem mass spectrometry
    Antelo-Dominguez, Angel
    Angel Cocho, Jose
    Jesus Tabernero, Maria
    Maria Bermejo, Ana
    Bermejo-Barrera, Pilar
    Moreda-Pineiro, Antonio
    TALANTA, 2013, 117 : 235 - 241
  • [45] Separation of Opiate Isomers Using Electrospray Ionization and Paper Spray Coupled to High-Field Asymmetric Waveform Ion Mobility Spectrometry
    Manicke, Nicholas E.
    Belford, Michael
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2015, 26 (05) : 701 - 705
  • [46] Effect of sample collection on α-galactosidase A enzyme activity measurements in dried blood spots on filter paper
    Olivova, Petra
    van der Veen, Kristen
    Cullen, Emmaline
    Rose, Michael
    Zhang, X. Kate
    Sims, Katherine B.
    Keutzer, Joan
    Browning, Marsha F.
    CLINICA CHIMICA ACTA, 2009, 403 (1-2) : 159 - 162
  • [47] Automatically High-Throughput Quantification by Paper Spray Ionization Mass Spectrometry for Multiple Pesticides in Wine
    Tianyang Guo
    Wei Yong
    Yiyang Dong
    Food Analytical Methods, 2019, 12 : 1208 - 1217
  • [48] Rapid Analysis of Bisphenol A and Its Analogues in Food Packaging Products by Paper Spray Ionization Mass Spectrometry
    Chen, Shuo
    Chang, Quanying
    Yin, Kai
    He, Qunying
    Deng, Yongxiu
    Chen, Bo
    Liu, Chengbin
    Wang, Ying
    Wang, Liping
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2017, 65 (23) : 4859 - 4865
  • [49] Coupling paper spray ionization with the flexible microtube plasma for the determination of low polar biomarkers in mass spectrometry
    Foest, Daniel
    Knodel, Alexander
    Brandt, Sebastian
    Franzke, Joachim
    ANALYTICA CHIMICA ACTA, 2022, 1201
  • [50] Automatically High-Throughput Quantification by Paper Spray Ionization Mass Spectrometry for Multiple Pesticides in Wine
    Guo, Tianyang
    Yong, Wei
    Dong, Yiyang
    FOOD ANALYTICAL METHODS, 2019, 12 (05) : 1208 - 1217