The development of the BRISP spectrometer at the Institut Laue-Langevin

被引:35
作者
Aisa, D
Babucci, E
Barocchi, F
Cunsolo, A
D'Anca, F
De Francesco, A
Formisano, F
Gahl, T
Guarini, E
Jahn, S
Laloni, A
Mutka, H
Orecchini, A
Petrillo, C
Sacchetti, F
Suck, JB
Venturi, G
机构
[1] Univ Perugia, INFM, I-06100 Perugia, Italy
[2] Univ Perugia, Dipartimento Fis, I-06100 Perugia, Italy
[3] Univ Florence, INFM, I-50019 Sesto Fiorentino, Italy
[4] Univ Florence, Dipartimento Fis, I-50019 Sesto Fiorentino, Italy
[5] INFM, Operat Grp Grenoble, F-38042 Grenoble, France
[6] TU Chemnitz, Inst Phys Mat Res & Liquids, D-09107 Chemnitz, Germany
[7] Inst Laue Langevin, F-38042 Grenoble, France
关键词
inelastic neutron scattering; neutron spectrometers and components;
D O I
10.1016/j.nima.2004.12.037
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Inelastic neutron scattering experiments for advanced investigations of the atomic and spin dynamics of matter at low momentum transfers (Neutron Brillouin Spectroscopy) require new instrumentation and efficient measuring techniques. In this paper we describe the development and expected performance of the BRISP thermal neutron spectrometer, which is going to be commissioned by the end of this year at the High-Flux Reactor of the Institut Laue-Langevin in Grenoble. This instrument is specially designed for small-angle spectroscopy at thermal neutron energies with good energy and wavevector transfer resolution. The use of the time-of-flight technique in combination with a two-dimensional position sensitive detector, which ensures an efficient data collection, makes this new spectrometer particularly suited for measuring changes in the dynamic structure factor induced by varying external parameters such as pressure, temperature and magnetic field. A detailed technical discussion, describing the operational characteristics and the potential of BRISP, is presented. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:620 / 642
页数:23
相关论文
共 40 条
[31]   CONDITIONS FOR HIGH-RESOLUTION IN A 3-AXIS CURVED-IDEAL CRYSTAL NEUTRON SPECTROMETER [J].
POPOVICI, M ;
STOICA, AD .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1983, 16 (07) :662-665
[32]   OPTICS OF CURVED-CRYSTAL NEUTRON SPECTROMETERS .1. 3-AXIS SPECTROMETERS [J].
POPOVICI, M ;
STOICA, AD ;
IONITA, I .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1987, 20 (02) :90-101
[33]  
PRICE DL, 1987, METHODS EXPT PHYS A, V23
[34]   COLLECTIVE EXCITATIONS IN DISORDERED-SYSTEMS [J].
SUCK, JB .
INTERNATIONAL JOURNAL OF MODERN PHYSICS B, 1993, 7 (16-17) :3003-3028
[35]  
SUCK JB, 1991, ILL ANN REPORT, P60
[36]  
SUCK JB, 1994, ILL ANN REPORT, P123
[37]   Design criteria for electronics for resistive charge division in thermal neutron detection [J].
Van Esch, P ;
Gahl, T ;
Guérard, B .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 526 (03) :493-500
[38]  
VENTURI G, 2003, J NEUTRON RES, V11, P165
[39]   Dynamics in liquids [J].
Verkerk, P .
JOURNAL OF PHYSICS-CONDENSED MATTER, 2001, 13 (34) :7775-7799
[40]  
Windsor C. G., 1981, PULSED NEUTRON SCATT