Insufficient sampling frequencies skew heart rate variability estimates: Implications for extracting heart rate metrics from neuroimaging and physiological data

被引:16
作者
Burma, Joel S. [1 ,2 ,3 ,4 ,5 ,6 ,7 ]
Lapointe, Andrew P. [3 ,4 ,6 ]
Soroush, Ateyeh [3 ,4 ,6 ,9 ]
Oni, Ibukunoluwa K. [3 ,4 ,6 ,9 ]
Smirl, Jonathan D. [1 ,2 ,3 ,4 ,5 ,6 ,7 ]
Dunn, Jeff F. [3 ,6 ,8 ,9 ]
机构
[1] Univ Calgary, Fac Kinesiol, Cerebrovasc Concuss Lab, Calgary, AB, Canada
[2] Univ Calgary, Fac Kinesiol, Sport Injury Prevent Res Ctr, Calgary, AB, Canada
[3] Univ Calgary, Hotchkiss Brain Inst, Calgary, AB, Canada
[4] Univ Calgary, Integrated Concuss Res Program, Calgary, AB, Canada
[5] Univ Calgary, Fac Kinesiol, Human Performance Lab, Calgary, AB, Canada
[6] Univ Calgary, Alberta Childrens Hosp Res Inst, Calgary, AB, Canada
[7] Univ Calgary, Libin Cardiovasc Inst Alberta, Calgary, AB, Canada
[8] Univ Calgary, Cumming Sch Med, Dept Radiol, Calgary, AB, Canada
[9] Univ Calgary, Cumming Sch Med, Dept Clin Neurosci, Calgary, AB, Canada
基金
加拿大健康研究院; 加拿大自然科学与工程研究理事会;
关键词
Heart rate variability; Sampling frequency; Electrocardiography; Validity; Downsampling; ELECTROCARDIOGRAM; RELIABILITY; PARAMETERS; SENSITIVITY; PREDICTION; MORTALITY; AGREEMENT; STRESS; VALUES; REST;
D O I
10.1016/j.jbi.2021.103934
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background: While cardiac pulsations are widely present within physiological and neuroimaging data, it is unknown the extent this information can provide valid and reliable heart rate and heart rate variability (HRV) estimates. The objective of this study was to demonstrate how a slight temporal shift due to an insufficient sampling frequency can impact the validity/accuracy of deriving cardiac metrics. Methods: Twenty-two participants were instrumented with valid/reliable industry-standard or open-source electrocardiograms. Five-minute lead II recordings were collected at 1000 Hz in an upright orthostatic position. Following artifact removal, the 1000 Hz recording for each participant was downsampled to frequencies ranging 2-500 Hz. The validity of each participant's downsampled recording was compared against their 1000 Hz recording ("reference-standard") using Bland-Altman plots with 95 % limits of agreement (LOA), coefficient of variation (CoV), intraclass correlation coefficients, and adjusted r-squared values. Results: Downsampled frequencies of >= 50 and >= 90 Hz produced highly robust measures with narrow logtransformed 95 % LOA (<+/- 0.01) and low CoV values (<= 3.5 %) for heart rate and HRV metrics, respectively. Below these thresholds, the log-transformed 95 % LOA became wider (LOA range: +/- 0.1-1.9) and more variable (CoV range: 1.5-111.6 %). Conclusion: These results provide an important consideration for obtaining cardiac information from physiological data. Compared to the "reference-standard" ECG, a seemingly negligible temporal shift of the systolic contraction (R wave) greater than 11-milliseconds (90 Hz) away from its true value, lessened the validity of the HRV. Further research is warranted to determine the minimum sampling frequency required to obtain valid heart rate/HRV metrics from pulsatile waveforms.
引用
收藏
页数:12
相关论文
共 71 条
[1]   Heart rate variability: a review [J].
Acharya, U. Rajendra ;
Joseph, K. Paul ;
Kannathal, N. ;
Lim, Choo Min ;
Suri, Jasjit S. .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2006, 44 (12) :1031-1051
[2]   ECG Interpretation Using the CRISP Method: A Guide for Nurses [J].
Atwood, Denise ;
Wadlund, Diana L. .
AORN JOURNAL, 2015, 102 (04) :396-405
[3]   Autonomic Dysregulation in Adolescent Concussion Is Sex- and Posture-Dependent [J].
Balestrini, Christopher S. ;
Moir, Marcy Erin ;
Abbott, Kolten C. ;
Klassen, Stephen A. ;
Fischer, Lisa K. ;
Fraser, Douglas D. ;
Shoemaker, Joel Kevin .
CLINICAL JOURNAL OF SPORT MEDICINE, 2021, 31 (03) :257-265
[4]   Reference values of heart rate variability [J].
Bauer, Axel ;
Camm, A. John ;
Cerutti, Sergio ;
Guzik, Przemyslaw ;
Huikuri, Heikki ;
Lombardi, Federico ;
Malik, Marek ;
Peng, Chung-Kang ;
Porta, Alberto ;
Sassi, Roberto ;
Schmidt, Georg ;
Schwartz, Peter J. ;
Stein, Phyllis K. ;
Yamamoto, Yoshiharu .
HEART RHYTHM, 2017, 14 (02) :302-303
[5]  
Becker Daniel E, 2006, Anesth Prog, V53, P53, DOI 10.2344/0003-3006(2006)53[53:FOEI]2.0.CO
[6]  
2
[7]   Does higher sampling rate (multiband plus SENSE) improve group statistics - An example from social neuroscience block design at 3T [J].
Bhandari, Ritu ;
Kirilina, Evgeniya ;
Caan, Matthan ;
Suttrup, Judith ;
De Sanctis, Teresa ;
De Angelis, Lorenzo ;
Keysers, Christian ;
Gazzola, Valeria .
NEUROIMAGE, 2020, 213
[8]   Parasympathetic baroreflexes and heart rate variability during acute stage of sport concussion recovery [J].
Bishop, Scott ;
Dech, Ryan ;
Baker, Taylor ;
Butz, Matthew ;
Aravinthan, Kaishan ;
Neary, J. Patrick .
BRAIN INJURY, 2017, 31 (02) :247-259
[9]   Heart rate variability and implication for sport concussion [J].
Bishop, Scott A. ;
Dech, Ryan T. ;
Guzik, Przemyslaw ;
Neary, J. Patrick .
CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2018, 38 (05) :733-742
[10]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310