Purpose: To analyse the risk factors for infection associated with central venous access device (CVAD) use in children with haemophilia. Methods: Risk factors for CVAD infection among patients with congenital haemophilia who had had a CVAD implanted at a single institution were evaluated utilizing the following variables: age at CVAD placement, age at end of study, number of days with a CVAD, percentage of lifetime with a CVAD, and history of inhibitor. Results: Fifty-nine patients had a total of 97 936 (median 1768 days per patient) CVAD days in the study period. The median age at CVAD placement was 2.7 years (range 0-14.0). Twenty-six (44%) patients reported CVAD infections during the study period from January 1993 to October 2000. Twenty-four patients had their CVAD replaced, 17 (71%) of whom reported having infections and seven (29%) of whom had a history of inhibitor. The strongest predictor for having any infections was inhibitor status (P = 0.16), although none of the risk factors had statistically significant effects. Among the 26 patients reporting infections, 42% had more than one CVAD-related infection. Seven patients had multiple infections involving the same organism. The mean rate of infection was 0.45 per 1000 catheter days, with a 95% confidence interval of 0.33-0.60. Those with a history of inhibitor had an infection rate of 0.66 compared with 0.38 per 1000 catheter days (P = 0.09) for those without a history of inhibitor. Patients who were older ( greater than the median age of 2.7) at CVAD placement had a lower rate of infection (0.29 vs. 0.65, P < 0.01) compared with those ≤2.7 years. Adjustment for inhibitor status had little impact on these results. For the group as a whole, the median time to first infection was 1977 days from CVAD placement. Patients who were older at CVAD placement or study exit had lower relative hazards of infection (P = 0.05 and P = 0.09 respectively), while those who had inhibitors had a higher but not statistically significant relative hazard of 1.88 (P = 0.13). Conclusions: These data reveal that while considerable numbers of patients develop CVAD-related infection, the interval between catheter placement and infection can be quite long. In addition, the earlier in life a CVAD is placed, the higher the risk of infectious complications, as evidenced by the tendency towards a higher infection rate. Measures to prevent CVAD-related infection might be focused on very young patients who appear to be at higher risk.
引用
收藏
页码:588 / 592
页数:5
相关论文
共 50 条
  • [21] Central Venous Access Catheters: Radiological Management of Complications
    U.K. Teichgräber
    B. Gebauer
    T. Benter
    H.-J. Wagner
    CardioVascular and Interventional Radiology, 2003, 26 : 321 - 333
  • [22] Infectious complications of percutaneous central venous catheterization in pediatric patients
    Garcia-Teresa, M. Angeles
    Casado-Flores, Juan
    Dominguez, M. Angel Delgado
    Roqueta-Mas, Jorge
    Cambra-Lasaosa, Francisco
    Concha-Torre, Andres
    Fernandez-Perez, Cristina
    INTENSIVE CARE MEDICINE, 2007, 33 (03) : 466 - 476
  • [23] Central venous catheter use - Part 2: infectious complications
    Polderman, KH
    Girbes, ARJ
    INTENSIVE CARE MEDICINE, 2002, 28 (01) : 18 - 28
  • [24] Burden of illness and costs among paediatric haemophilia patients with and without central venous access devices treated in US hospitals
    Buckley, B.
    Dreyfus, J.
    Prasad, M.
    Gayle, J.
    Kendter, J.
    Hall, E., II
    HAEMOPHILIA, 2018, 24 (03) : E93 - E102
  • [25] MRI after removal of central venous access device reveals a high number of asymptomatic thromboses in children with haemophilia
    Ranta, S.
    Kalajoki-Helmio, T.
    Pouttu, J.
    Makipernaa, A.
    HAEMOPHILIA, 2012, 18 (04) : 521 - 526
  • [26] Multivariate analysis on complications of central venous access devices in children with cancer and severe disease influenced by catheter tip position and vessel insertion site (A STROBE-compliant study)
    Hofmann, Sarah
    Goedeke, Jan
    Koenig, Tatjana T.
    Poplawski, Alicia
    Muensterer, Oliver J.
    Faber, Joerg
    Beck, Olaf
    SURGICAL ONCOLOGY-OXFORD, 2020, 34 : 17 - 23
  • [27] Minimizing Complications Associated With Percutaneous Central Venous Catheter Placement in Children: Recent Advances
    Costello, John M.
    Clapper, Timothy C.
    Wypij, David
    PEDIATRIC CRITICAL CARE MEDICINE, 2013, 14 (03) : 273 - 283
  • [28] Central venous catheter: epidemiology, diagnosis, prevention and treatment of infectious complications
    Quinet, B.
    ARCHIVES DE PEDIATRIE, 2006, 13 (06): : 718 - 720
  • [29] Retrospective comparative examination of the long term effects of venous access devices on upper extremity limb measurement in children with haemophilia: pilot observations from a single haemophilia treatment centre
    Christie, B. A.
    Baumann, K.
    Kurth, M. H.
    HAEMOPHILIA, 2006, 12 (05) : 526 - 530
  • [30] Contrast venography in young haemophiliacs with implantable central venous access devices
    Medeiros, D
    Miller, KL
    Rollins, NK
    Buchanan, GR
    HAEMOPHILIA, 1998, 4 (01) : 10 - 15