Surveillance of infectious complications associated with central venous access devices in children with haemophilia

被引:41
|
作者
Tarantino, MD
Lail, A
Donfield, SM
Lynn, H
Peddle, L
Hunsberger, S
Shapiro, AD
机构
[1] Univ Illinois, Comprehens Bleeding Disorders Ctr, Coll Med, Peoria, IL 61614 USA
[2] Rho Inc, Chapel Hill, NC USA
[3] Indiana Hemophilia & Thrombosis Ctr, Indianapolis, IN USA
关键词
catheter-related infection; central venous catheter; haemophilia; inhibitor;
D O I
10.1046/j.1365-2516.2003.00793.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To analyse the risk factors for infection associated with central venous access device (CVAD) use in children with haemophilia. Methods: Risk factors for CVAD infection among patients with congenital haemophilia who had had a CVAD implanted at a single institution were evaluated utilizing the following variables: age at CVAD placement, age at end of study, number of days with a CVAD, percentage of lifetime with a CVAD, and history of inhibitor. Results: Fifty-nine patients had a total of 97 936 (median 1768 days per patient) CVAD days in the study period. The median age at CVAD placement was 2.7 years (range 0-14.0). Twenty-six (44%) patients reported CVAD infections during the study period from January 1993 to October 2000. Twenty-four patients had their CVAD replaced, 17 (71%) of whom reported having infections and seven (29%) of whom had a history of inhibitor. The strongest predictor for having any infections was inhibitor status (P = 0.16), although none of the risk factors had statistically significant effects. Among the 26 patients reporting infections, 42% had more than one CVAD-related infection. Seven patients had multiple infections involving the same organism. The mean rate of infection was 0.45 per 1000 catheter days, with a 95% confidence interval of 0.33-0.60. Those with a history of inhibitor had an infection rate of 0.66 compared with 0.38 per 1000 catheter days (P = 0.09) for those without a history of inhibitor. Patients who were older ( greater than the median age of 2.7) at CVAD placement had a lower rate of infection (0.29 vs. 0.65, P < 0.01) compared with those ≤2.7 years. Adjustment for inhibitor status had little impact on these results. For the group as a whole, the median time to first infection was 1977 days from CVAD placement. Patients who were older at CVAD placement or study exit had lower relative hazards of infection (P = 0.05 and P = 0.09 respectively), while those who had inhibitors had a higher but not statistically significant relative hazard of 1.88 (P = 0.13). Conclusions: These data reveal that while considerable numbers of patients develop CVAD-related infection, the interval between catheter placement and infection can be quite long. In addition, the earlier in life a CVAD is placed, the higher the risk of infectious complications, as evidenced by the tendency towards a higher infection rate. Measures to prevent CVAD-related infection might be focused on very young patients who appear to be at higher risk.
引用
收藏
页码:588 / 592
页数:5
相关论文
共 50 条
  • [1] Complications of central venous access devices in paediatric haemophilia patients
    Domm, JA
    Hudson, MG
    Janco, RL
    HAEMOPHILIA, 2003, 9 (01) : 50 - 56
  • [2] Central venous access devices in haemophilia
    Valentino, LA
    Ewenstein, B
    Navickis, RJ
    Wilkes, MM
    HAEMOPHILIA, 2004, 10 (02) : 134 - 146
  • [3] Complications associated with central venous access device in children with haemophilia: a nationwide multicentre study in Finland
    Vepsalainen, K.
    Lassila, R.
    Arola, M.
    Lahteenmaki, P.
    Mottonen, M.
    Makipernaa, A.
    Riikonen, P.
    HAEMOPHILIA, 2015, 21 (06) : 747 - 753
  • [4] Complications associated with central venous access devices use in children with congenital bleeding disorders
    Guimaraes, P.
    Loran, C.
    Rayment, R.
    BRITISH JOURNAL OF HAEMATOLOGY, 2018, 181 : 138 - 139
  • [5] The impact of clinical practice on the outcome of central venous access devices in children with haemophilia
    Khair, K.
    Ranta, S.
    Thomas, A.
    Lindvall, K.
    HAEMOPHILIA, 2017, 23 (04) : E276 - E281
  • [6] Long-term results of central venous access devices in children with haemophilia
    Upadhyaya, Manasvi
    Richards, Michael
    Buckham, Sarah
    Squire, B. R.
    PEDIATRIC SURGERY INTERNATIONAL, 2006, 25 (06) : 503 - 506
  • [7] Long-term results of central venous access devices in children with haemophilia
    Manasvi Upadhyaya
    Michael Richards
    Sarah Buckham
    B. R. Squire
    Pediatric Surgery International, 2009, 25 : 503 - 506
  • [8] Central venous access catheters in children with haemophilia
    Blanchette, VS
    AlMusa, A
    Stain, AM
    Filler, RM
    Ingram, J
    BLOOD COAGULATION & FIBRINOLYSIS, 1996, 7 : S39 - S44
  • [9] A prospective clinical trial of implantable central venous access in children with haemophilia
    Santagostino, E
    Gringeri, A
    Muca-Perja, M
    Mannucci, PM
    BRITISH JOURNAL OF HAEMATOLOGY, 1998, 102 (05) : 1224 - 1228
  • [10] Central venous catheter: Infectious complications
    Sakic, K.
    Skrlin, J.
    Husedzinovic, I.
    Bosnjak, D.
    NEUROLOGIA CROATICA, 2003, 52 : 45 - 52