Hydrogen peroxide biosensor based on microperoxidase-11 entrapped in lipid membrane

被引:49
|
作者
Huang, WM [1 ]
Jia, JB [1 ]
Zhang, ZL [1 ]
Han, XJ [1 ]
Tang, JL [1 ]
Wang, JG [1 ]
Dong, SJ [1 ]
Wang, EK [1 ]
机构
[1] Chinese Acad Sci, Changchun Inst Appl Chem, State Key Lab Electroanalyt Chem, Changchun 130022, Peoples R China
来源
BIOSENSORS & BIOELECTRONICS | 2003年 / 18卷 / 10期
关键词
microperoxidase-11; lipid membrane; didodecyldimethylammonium bromide; biosensor;
D O I
10.1016/S0956-5663(03)00070-8
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A highly catalytic activity microperoxidase-11 (MP-11) biosensor for H2O2 was developed to immobilizing the heme peptide in didodecyldimethylammonium bromide (DDAB) lipid membrane. The enzyme electrode thus obtained responded to H2O2 without electron mediator or promoter, at a potential of +0.10 V versus Ag \ AgCl. A linear calibration curve is obtained over the range from 2.0 x 10(-5) to 2.4 x 10(-3) M. The biosensor responds to hydrogen peroxide in 15 s and has a detection limit of 8 x 10(-7) M (S/N = 3) Providing a natural environment with lipid membrane for protein immobilization and maintenance of protein functions is a suitable option for the design of biosensors. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1225 / 1230
页数:6
相关论文
共 50 条
  • [31] Hydrogen peroxide sensitive biosensor based on plant peroxidases entrapped in Os-modified polypyrrole films
    Gaspar, S
    Habermüller, K
    Csöregi, E
    Schuhmann, W
    SENSORS AND ACTUATORS B-CHEMICAL, 2001, 72 (01) : 63 - 68
  • [32] An Electrochemical Hydrogen Peroxide Biosensor Based on Polydopamine-Entrapped G-Quadruplex-Hemin DNAzyme
    Gao Ai
    Wang Yu-Ru
    He Xi-Wen
    Yin Xue-Bo
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 40 (10) : 1471 - 1476
  • [33] Oxidation of pyocyanin, a cytotoxic product from Pseudomonas aeruginosa, by microperoxidase 11 and hydrogen peroxide
    Reszka, KJ
    O'Malley, Y
    McCormick, ML
    Denning, GM
    Britigan, BE
    FREE RADICAL BIOLOGY AND MEDICINE, 2004, 36 (11) : 1448 - 1459
  • [34] Preparation of a microperoxidase and ferrocene-immobilized polyion complex membrane for the detection of hydrogen peroxide
    Yabuki, S
    Mizutani, F
    Hirata, Y
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 468 (01) : 117 - 120
  • [35] A biofuel cell based on two immiscible solvents and glucose oxidase and microperoxidase-11 monolayer-functionalized electrodes
    Katz, E
    Filanovsky, B
    Willner, I
    NEW JOURNAL OF CHEMISTRY, 1999, 23 (05) : 481 - 487
  • [36] Hydrogen Peroxide Biosensor based on Titanium Oxide
    Halim, Nur Hamidah Abdul
    Heng, Lee Yook
    Hashim, Uda
    2015 UKM FST POSTGRADUATE COLLOQUIUM, 2015, 1678
  • [37] A hydrogen peroxide biosensor based on polyaniline/FTO
    Wang, Peng
    Li, Shengqi
    Kan, Jinqing
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 137 (02) : 662 - 668
  • [38] Elaboration of a new hydrogen peroxide biosensor using microperoxidase 8 (MP8) immobilized on a polypyrrole coated electrode
    Korri-Youssoufi, H.
    Desbenoit, N.
    Ricoux, R.
    Mahy, J. -P.
    Lecomte, S.
    MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2008, 28 (5-6): : 855 - 860
  • [39] Hydrogen peroxide biosensor based on methylene blue incorporated into nafion membrane as electron transfer mediator
    Ying, TL
    Wang, ZJ
    Liu, HY
    Sun, K
    Deng, JQ
    PROGRESS IN BIOCHEMISTRY AND BIOPHYSICS, 1997, 24 (03) : 254 - 258
  • [40] Comparison of peroxidase activities of hemin, cytochrome c and microperoxidase-11 in molecular solvents and imidazolium-based ionic liquids
    Laszlo, JA
    Compton, DL
    JOURNAL OF MOLECULAR CATALYSIS B-ENZYMATIC, 2002, 18 (1-3) : 109 - 120