Comparison of auscultatory and oscillometric blood pressures

被引:121
|
作者
Park, MK
Menard, SW
Yuan, C
机构
[1] Univ Texas, Hlth Sci Ctr, Dept Pediat, Sch Med, San Antonio, TX 78229 USA
[2] Univ Texas, Hlth Sci Ctr, Sch Nursing, San Antonio, TX 78229 USA
[3] Univ Texas, Hlth Sci Ctr, Dept Comp Resources, San Antonio, TX 78229 USA
来源
关键词
D O I
10.1001/archpedi.155.1.50
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Objective: To study the differences in blood pressure readings between the auscultatory and oscillometric (Dinamap model 8100; Critikon, Tampa, Fla) methods. Design: Survey of 2 blood pressure instruments. Setting: Public schools. Participants: Seven thousand two hundred eight schoolchildren aged 5 through 17 years. Main Outcome Measure: Blood pressure levels. Results: For all children. combined, Dinamap systolic pressure readings were 10 mm Hg higher (95% confidence interval, -4 to 24 mm Hg) than the auscultatory systolic pressure readings. Dinamap diastolic pressure readings were 5 mm Hg higher (95% confidence interval, -14 to 23 mm Hg) than the auscultatory Korotkoff phase V diastolic pressure readings. Conclusion: These findings preclude the interchange of readings by the 2 methods. Caution must be exercised in the diagnosis of hypertension when an automated device is used.
引用
收藏
页码:50 / 53
页数:4
相关论文
共 50 条
  • [1] Comparison of the auscultatory and oscillometric mean blood pressures in man
    Davis, G.
    Geddes, L.A.
    Journal of Clinical Engineering, 1988, 13 (06) : 443 - 446
  • [2] Comparison of Automated Oscillometric Versus Auscultatory Blood Pressure Measurement
    Landgraf, Johanna
    Wishner, Stanley H.
    Kloner, Robert A.
    AMERICAN JOURNAL OF CARDIOLOGY, 2010, 106 (03): : 386 - 388
  • [3] Comparison of Repeatability of Blood Pressure Measurements between Oscillometric and Auscultatory Methods
    Liu, Chengyu
    Zheng, Dingchang
    Griffiths, Clive
    Murray, Alan
    2015 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), 2015, 42 : 1073 - 1076
  • [4] Comparison of auscultatory and oscillometric automated blood pressure monitors in the setting of preeclampsia
    Natarajan, P
    Shennan, AH
    Penny, J
    Halligan, AW
    de Swiet, M
    Anthony, J
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1999, 181 (05) : 1203 - 1210
  • [5] COMPARISON BETWEEN OSCILLOMETRIC AND AUSCULTATORY BLOOD PRESSURE MEASUREMENT IN CHILDREN AND ADOLESCENTS
    Duzova, Ali
    Baskin, Esra
    Cakar, Nilgun
    Soylemezoglu, Oguz
    Yalcinkaya, Fatos
    Hayran, Mutlu
    PEDIATRIC NEPHROLOGY, 2018, 33 (10) : 1818 - 1819
  • [6] AUSCULTATORY AND OSCILLOMETRIC AMBULATORY BLOOD PRESSURE MONITORING: METHODS COMPARISON IN ADULT PATIENTS
    Zhemanyuk, Svitlana Pavlina
    Syvolap, Vitaliy Victorovich
    JOURNAL OF HYPERTENSION, 2023, 41 : E208 - E208
  • [7] Auscultatory versus oscillometric measurement of blood pressure in octogenarians
    Rosholm, Jens-Ulrik
    Arnspang, Sidsel
    Matzen, Lars
    Jacobsen, Ib A.
    BLOOD PRESSURE, 2012, 21 (05) : 269 - 272
  • [8] Comparison between oscillometric and auscultatory methods of ambulatory blood pressure measurement in hemodialysis patients
    Fagugli, RM
    Vecchi, L
    Valente, F
    Santirosi, P
    Laviola, MM
    CLINICAL NEPHROLOGY, 2002, 57 (04) : 283 - 288
  • [9] EFFECT OF UNDERCUFFING ON AUSCULTATORY AND OSCILLOMETRIC BLOOD PRESSURE MEASUREMENT
    Albuquerque, Nila
    Padwal, Raj
    Araujo, Thelma
    JOURNAL OF HYPERTENSION, 2021, 39 : E130 - E130
  • [10] COMPARISONS OF AUSCULTATORY AND OSCILLOMETRIC BLOOD-PRESSURE MEASUREMENTS
    PARK, MK
    WEAVER, MG
    LEE, DH
    PEDIATRIC RESEARCH, 1989, 25 (04) : A104 - A104