Problems, complications, and reinterventions in 4893 onlay humeral lateralized reverse shoulder arthroplasties: a systematic review (part I-complications)

被引:8
作者
Ascione, Francesco [1 ,2 ]
Panni, Alfredo Schiavone [3 ]
Braile, Adriano [3 ]
Corona, Katia [4 ]
Toro, Giuseppe [3 ]
Capuano, Nicola [1 ]
Romano, Alfonso M. [1 ,2 ]
机构
[1] Osped Buon Consiglio Fatebenefratelli, Dept Orthopaed & Trauma Surg, Via A Manzoni 220, I-80123 Naples, NA, Italy
[2] Campolongo Hosp, Orthoped & Sport Med Unit, Salerno, Italy
[3] Univ Campania Luigi Vanvitelli, Dipartimento Multidisciplinare Specialita Med Chi, Naples, Italy
[4] Univ Molise, Dept Med & Hlth Sci, Campobasso, Italy
关键词
Grammont; Results; Revision; Humeral offset; Dislocation; Infection; Radiographic findings; CLINICAL-OUTCOMES; SUBSCAPULARIS REPAIR; CUFF; PROSTHESIS; ROTATION; FRACTURE; DESIGN; IMPACT; HEMIARTHROPLASTY; REOPERATIONS;
D O I
10.1186/s10195-021-00592-w
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Several modifications to the original Grammont reverse shoulder arthroplasty (RSA) design have been proposed to prevent distinctive issues, such as both glenoid and humeral lateralization. The aim of this systematic review was to determine rates of problems, complications, reoperations, and revisions after onlay lateralized humeral stem RSA, hypothesizing that these are design related. Methods This systematic review was performed in accordance with the PRISMA statement guidelines. A literature search was conducted (01.01.2000-14.04.2020) using PubMed, Cochrane Reviews, Scopus, and Google Scholar employing several combinations of keywords: "reverse shoulder arthroplasty," "reverse shoulder prosthesis," "inverse shoulder arthroplasty," "inverse shoulder prosthesis," "problems," "complications," "results," "outcomes," "reoperation," "revision." Results Thirty-one studies with 4893 RSA met inclusion criteria. The 892 postoperative problems and 296 postoperative complications represented overall problem and complication rates of 22.7% and 7.5%, respectively. Forty-one reoperations and 63 revisions resulted, with an overall reoperation rate of 1.7% and overall revision rate of 2.6%. Conclusions Problem, complication, and reintervention rates proved acceptable when implanting a high humeral lateralization stem in RSA. The most frequent problem was scapular notching (12.6%), and the most common postoperative complication was scapular stress fracture (1.8%). An overall humeral complication rate of 1.9% was identified, whereas short stems reported no humeral fractures or stem loosening. Infections (1.3%) proved to be the most common reason for component revision, and instability had a complication rate of 0.8%.
引用
收藏
页数:14
相关论文
共 68 条
[1]  
Aibinder WR, 2019, BONE JOINT J, V101B, P610, DOI [10.1302/0301-620X.101B5.BJJ-2018-1374.R1, 10.1302/0301-620X.101B5.BJJ-2018-1374]
[2]   Anatomic total shoulder arthroplasty with posterior capsular plication versus reverse shoulder arthroplasty in patients with biconcave glenoids: A matched cohort study [J].
Alentorn-Geli, Eduard ;
Wanderman, Nathan R. ;
Assenmacher, Andrew T. ;
Sperling, John W. ;
Cofield, Robert H. ;
Sanchez-Sotelo, Joaquin .
JOURNAL OF ORTHOPAEDIC SURGERY, 2018, 26 (02)
[3]   Reverse shoulder arthroplasty. Part 2: Systematic review of reoperations, revisions, problems, and complications [J].
Alentorn-Geli, Eduard ;
Samitier, Gonzalo ;
Torrens, Carlos ;
Wright, Thomas W. .
INTERNATIONAL JOURNAL OF SHOULDER SURGERY, 2015, 9 (02) :60-67
[4]  
Ascione F., 2017, J SHOULDER ELB ARTHR, V1, DOI [10.1177/2471549217746272, DOI 10.1177/2471549217746272]
[5]   Experience-optimised fast track improves outcomes and decreases complications in total knee arthroplasty [J].
Ascione, Francesco ;
Braile, Adriano ;
Romano, Alfonso Maria ;
di Giunta, Angelo ;
Masciangelo, Marco ;
Senorsky, Eric Hamrin ;
Samuelsson, Kristian ;
Marzano, Nicola .
KNEE, 2020, 27 (02) :500-508
[6]   Increased scapular spine fractures after reverse shoulder arthroplasty with a humeral onlay short stem: an analysis of 485 consecutive cases [J].
Ascione, Francesco ;
Kilian, Christopher M. ;
Laughlin, Mitzi S. ;
Bugelli, Giulia ;
Domos, Peter ;
Neyton, Lionel ;
Godeneche, Arnaud ;
Edwards, T. Bradley ;
Walch, Gilles .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2018, 27 (12) :2183-2190
[7]   Long-term humeral complications after Grammont-style reverse shoulder arthroplasty [J].
Ascione, Francesco ;
Domos, Peter ;
Guarrella, Vincenzo ;
Chelli, Mikael ;
Boileau, Pascal ;
Walch, Gilles .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2018, 27 (06) :1065-1071
[8]   Grammont reverse prosthesis: Design, rationale, and biomechanics [J].
Boileau, P ;
Watkinson, DJ ;
Hatzidakis, AM ;
Balg, F .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2005, 14 (01) :147S-161S
[9]   Complications and revision of reverse total shoulder arthroplasty [J].
Boileau, P. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2016, 102 (01) :S33-S43
[10]  