Biomimetic enhanced chemiluminescence of luminol-H2O2 system by manganese (III) deuteroporphyrin and its application in flow injection determination of phenol at trace level

被引:24
作者
Xu, Shichao [1 ]
Liu, Wenwen [2 ]
Hu, Bingcheng [1 ]
Cao, Wei [2 ]
Liu, Zuliang [1 ]
机构
[1] Nanjing Univ Sci & Technol, Coll Chem Engn, Nanjing 210094, Jiangsu, Peoples R China
[2] Univ Jinan, Sch Chem & Chem Engn, Jinan 250022, Shandong, Peoples R China
关键词
Luminol; Deuteroporphyrin; Phenol; Chemiluminescence; Free radical; PORPHYRIN COMPLEX; VOLATILE PHENOLS; OXIDATION; MICROEXTRACTION; METALLOPORPHYRINS; CATALYSIS; CAPACITY; ACIDS;
D O I
10.1016/j.jphotochem.2011.10.021
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A novel, sensitive and high selective flow-injection chemiluminescence (FI-CL) method for the determination of phenol is reported, based upon its decreasing effect on the CL reaction of luminol with hydrogen peroxide catalyzed by manganese (III) deuteroporphyrin [MnDP, Scheme 1, 3] in alkaline solution. Under the selected optimized experimental conditions, the relative CL intensity was linear with phenol in the range of 4.0 x 10(-9) to 4.0 x 10(-7) g mL(-1). The detection limit (3 sigma) was 6.3 x 10(-10) g mL(-1) and the relative standard deviation for 1.0 x 10(-7) g mL(-1) phenol (n = 11) was 2.99%. The regression equation was I = 120.79 + 1.14 x 1010c (R = 0.9936). This method has been applied to the determination of phenol in water with satisfactory results. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:32 / 37
页数:6
相关论文
共 31 条
[1]   Soybean peroxidase-catalyzed oxidation of luminol by hydrogen peroxide [J].
Alpeeva, IS ;
Sakharov, IY .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2005, 53 (14) :5784-5788
[2]  
[Anonymous], 2009, WATER QUALITY DETERM
[3]   An investigation into the reaction of hemin-catalysed luminol oxidation by peroxy compounds [J].
Baj, Stefan ;
Krawczyk, Tomasz .
JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2006, 183 (1-2) :111-120
[4]   Evaluation of antiradical capacity by H2O2-hemin-induced luminol chemiluminescence [J].
Bastos, EL ;
Romoff, P ;
Eckert, CR ;
Baader, WJ .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2003, 51 (25) :7481-7488
[5]   Simple high-performance liquid chromatographic analysis of phenol and p-cresol in urine and feces [J].
Birkett, AM ;
Jones, GP ;
Muir, JG .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1995, 674 (02) :187-191
[6]   Sensitive phenol determination based on co-modifying tyrosinase and palygorskite on glassy carbon electrode [J].
Chen, Jing ;
Jin, Yeling .
MICROCHIMICA ACTA, 2010, 169 (3-4) :249-254
[7]   FLOW-INJECTION AND LIQUID-CHROMATOGRAPHIC POSTCOLUMN DETECTION OF AMINO-ACIDS BY MIMETIC PEROXIDASE-CATALYZED CHEMILUMINESCENCE REACTION [J].
CI, YX ;
TIE, JK ;
WANG, QW ;
CHANG, WB .
ANALYTICA CHIMICA ACTA, 1992, 269 (01) :109-114
[8]   EVIDENCE FOR A FAST (MAJOR) AND SLOW (MINOR) PATHWAY IN THE SCHUMM DEVINYLATION REACTION OF VINYL PORPHYRINS [J].
DINELLO, RK ;
DOLPHIN, DH .
JOURNAL OF ORGANIC CHEMISTRY, 1981, 46 (17) :3498-3502
[9]   Determination of volatile phenols in red wines by dispersive liquid-liquid microextraction and gas chromatography-mass spectrometry detection [J].
Farina, Laura ;
Boido, Eduardo ;
Carrau, Francisco ;
Dellacassa, Eduardo .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1157 (1-2) :46-50
[10]   Detection and characterization of an oxomanganese(V) porphyrin complex by rapid-mixing stopped-flow spectrophotometry [J].
Groves, JT ;
Lee, JB ;
Marla, SS .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1997, 119 (27) :6269-6273