Phantom investigation of phase-inversion-based dual-frequency excitation imaging for improved contrast display

被引:1
|
作者
Shen, Che-Chou [2 ]
Su, Shin-Yuan [1 ]
Cheng, Chih-Hao [1 ]
Yeh, Chih-Kuang [1 ]
机构
[1] Natl Tsing Hua Univ, Dept Biomed Engn & Environm Sci, Hsinchu 30013, Taiwan
[2] Natl Taiwan Univ Sci & Technol, Dept Elect Engn, Taipei, Taiwan
关键词
Dual-frequency excitation; Phase-inversion technique; Contrast-to-tissue ratio; DOPPLER; MOTION; AGENTS;
D O I
10.1016/j.ultras.2011.06.006
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective: The goal of this work is to examine the effects of pulse-inversion (PI) technique in combination with dual-frequency (DF) excitation method to separate the high-order nonlinear responses from microbubble contrast agents for improvement of image contrast. DF excitation method has been previously developed to induce the low-frequency ultrasound nonlinear responses from bubbles by using the composition of two high-frequency sinusoids (f(1) and f(2)). Motivation: Although the simple filtering was conventionally utilized to provide signal separation, the PI approach is better in the sense that it minimizes the mutual interferences among these high-order nonlinear responses in the presence of spectral overlap. The novelty of the work is that, in addition to the common PI summation, the PI subtraction was also applied in DF excitation method. Methods: DF excitation pulses having an envelope frequency of 3 MHz (i.e., f(1) = 8.5 MHz and f(2) = 11.5 MHz) with pulse lengths of 3-10 mu s and the pressure amplitudes from 0.5 to 1.5 MPa were used to interrogate the nonlinear responses of SonoVue (TM) microbubbles in the phantom experiments. The high-order nonlinear responses in the DF excitation were extracted for contrast imaging using PI summation for even-order nonlinear components or PI subtraction for odd-order nonlinear ones. Results: Our results indicated that, as compared to the conventional filtering technique, the PI processing effectively increases the contrast-to-tissue ratio (CTR) of the third-order nonlinear response at 5.5 MHz and the fourth-order nonlinear response at 6 MHz by 2-5 dB. For these high-order nonlinear components, the CTR increase varies with the transmission pressures from 0.5 to 1.5 MPa due to the microbubbles' displacement induced by the radiation force of DF excitation. Conclusions: For DF excitation technique, the PI processing can help to extract either the odd-order or the even-order nonlinear components for higher CTR estimates. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:25 / 32
页数:8
相关论文
共 50 条
  • [1] INVESTIGATION OF DUAL-FREQUENCY EXCITATION AND THE INFLUENCE OF EXCITATION PHASE ON A CONSTRAINED CANTILEVERED BEAM SYSTEM
    Huang, Wei
    Atzil, Aaron M.
    Dick, Andrew J.
    PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, 2014, VOL 4, 2014,
  • [2] Range Side-lobe Inversion for Dual-Frequency Harmonic Imaging with Chirp Excitation
    Shen, Che-Chou
    Peng, Chun-Kai
    2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 33 - 36
  • [3] Dual-frequency chirp imaging for contrast detection
    Cheng, Chih-Hao
    Shen, Che-Chou
    Yeh, Chih-Kuang
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (09): : 2767 - 2778
  • [4] Phase-Dependent Dual-Frequency Contrast Imaging at Sub-Harmonic Frequency
    Shen, Che-Chou
    Cheng, Chih-Hao
    Yeh, Chih-Kuang
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2011, 58 (02) : 379 - 388
  • [5] Dual-Frequency Transducer for Nonlinear Contrast Agent Imaging
    Guiroy, Axel
    Novell, Anthony
    Ringgaard, Erling
    Lou-Moeller, Rasmus
    Gregoire, Jean-Marc
    Abellard, Andre-Pierre
    Zawada, Tomasz
    Bouakaz, Ayache
    Levassort, Franck
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2013, 60 (12) : 2634 - 2644
  • [6] Dual-frequency transducer for nonlinear contrast agent imaging
    Guiroy, A.
    Abellard, A.
    Levassort, F.
    Ringgaard, E.
    Lou-Moeller, R.
    Zawada, T.
    Novell, A.
    Gregoire, J. M.
    Bouakaz, A.
    2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012,
  • [7] Characterization of an Array-Based Dual-Frequency Transducer for Superharmonic Contrast Imaging
    Yang, Jing
    Cherin, Emmanuel
    Yin, Jianhua
    Newsome, Isabel G.
    Kierski, Thomas M.
    Pang, Guofeng
    Carnevale, Claudia A.
    Dayton, Paul A.
    Foster, F. Stuart
    Demore, Christine E. M.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (07) : 2419 - 2431
  • [8] Tissue Harmonic Compounded Imaging with Dual-Frequency Chirp Excitation
    Lin, Chin-Hsiang
    Shen, Che-Chou
    2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012, : 370 - 373
  • [9] Design of Chirp Excitation Waveform for Dual-Frequency Harmonic Contrast Detection
    Shen, Che-Chou
    Chiu, Yi-Yuan
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (10) : 2198 - 2206
  • [10] Dual-Frequency Chirp Excitation for Passive Cavitation Imaging in the Brain
    Lin, Hsiang-Ching
    Fan, Ching-Hsiang
    Ho, Yi-Ju
    Yeh, Chih-Kuang
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2020, 67 (06) : 1127 - 1140