Management of Paprosky type three B acetabular defects by custom-made components: early results

被引:23
作者
Aprato, Alessandro [1 ]
Giachino, Matteo [1 ]
Bedino, Paolo [1 ]
Mellano, Danilo [1 ]
Piana, Raimondo [1 ]
Masse, Alessandro [1 ]
机构
[1] Univ Turin, Orthopaed Dept, Citta Salute & Sci, Viale 25 Aprile 137 Int 6, I-10133 Turin, Italy
关键词
Hip; Revision; THA; Custom-made; Acetabular defect; Paprosky; TOTAL HIP-ARTHROPLASTY; PELVIC DISCONTINUITY; FOLLOW-UP; REVISION ARTHROPLASTY; BONE LOSS; RECONSTRUCTION; CAGE; MINIMUM; GRAFT; CUP;
D O I
10.1007/s00264-018-4203-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeOur study aims at the evaluation of the recently introduced Lima Promade custom-made acetabular device for the treatment of complex acetabular Paprosky 3B defects.MethodsBetween 2016 and 2018, eight patients with major acetabular osteolysis and multiple revisions history were treated with a custom-made implant in a single centreand by a single surgeon. We assessed patients' demographics, peri-operative data, and complications and a specific questionnaire was submitted to the surgeon after each procedure.ResultsAll the devices were correctly positioned. In two over eight cases, a post-operative dislocation occurred, where extensive soft tissue impairment was present. The questionnaire showed a good pre-operative and intra-operative experience of the surgeon.ConclusionsThe Promade custom-made acetabular system showed encouraging results for complex defects and the entire procedure was positively rated. Further analysis with a higher number of cases and a longer follow-up should be performed for a complete clinical and cost-effective evaluation.
引用
收藏
页码:117 / 122
页数:6
相关论文
共 28 条
  • [1] Aprato A, 2017, 3D APPL HIP SURG, P162
  • [2] Australian Orthopedic Association, 2017, NAT JOINT REPL REG
  • [3] Alfaro JJB, 2010, HIP INT, V20, pS119, DOI 10.5301/HIP.2010.5297
  • [4] Treatment options and allograft use in revision total hip arthroplasty
    Brubaker, Shawn M.
    Brown, Thomas E.
    Manaswi, Abhijit
    Mihalko, William M.
    Cui, Quanjun
    Saleh, Khaled J.
    [J]. JOURNAL OF ARTHROPLASTY, 2007, 22 (07) : 52 - 56
  • [5] Occult intra-operative periprosthetic fractures of the acetabulum may affect implant survival
    Dammerer, Dietmar
    Putzer, David
    Glodny, Bernhard
    Petersen, Johannes
    Arrich, Ferdi
    Krismer, Martin
    Biedermann, Rainer
    [J]. INTERNATIONAL ORTHOPAEDICS, 2019, 43 (07) : 1583 - 1590
  • [6] Use of structural bone graft with cementless acetabular cups in total hip arthroplasty
    DeWal, H
    Chen, F
    Su, E
    Di Cesare, PE
    [J]. JOURNAL OF ARTHROPLASTY, 2003, 18 (01) : 23 - 28
  • [7] Use of porous tantalum components in Paprosky two and three acetabular revision. A minimum five-year follow-up of fifty one hips
    Flecher, Xavier
    Appy, Benjamin
    Parratte, Sebastien
    Ollivier, Matthieu
    Argenson, Jean-Noel
    [J]. INTERNATIONAL ORTHOPAEDICS, 2017, 41 (05) : 911 - 916
  • [8] Does a Cemented Cage Improve Revision THA for Severe Acetabular Defects?
    Hansen, Erik
    Shearer, David
    Ries, Michael D.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (02) : 494 - 502
  • [9] Use of custom triflanged acetabular components in revision total hip arthroplasty
    Holt, GE
    Dennis, DA
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (429) : 209 - 214
  • [10] Issack Paul S, 2009, Am J Orthop (Belle Mead NJ), V38, P550