A left ventricular phantom for 3D echocardiographic twist measurements

被引:6
作者
Hjertaas, Johannes Just [1 ]
Matre, Knut [1 ]
机构
[1] Univ Bergen, Haukeland Univ Hosp, Dept Clin Sci, N-5021 Bergen, Norway
来源
BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK | 2020年 / 65卷 / 02期
关键词
in vitro; myocardial twist; rotation; sonomicrometer; speckle tracking; three-dimensional echocardiography; volume rate; SPECKLE-TRACKING ECHOCARDIOGRAPHY; 3-DIMENSIONAL ECHOCARDIOGRAPHY; MYOCARDIAL STRAIN; CARDIAC MOTION; FRAME RATE; VALIDATION; 2D; MECHANICS; CHAMBER; QUANTIFICATION;
D O I
10.1515/bmt-2019-0096
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Traditional two-dimensional (2D) ultrasound speckle tracking echocardiography (STE) studies have shown a wide range of twist values, also for normal hearts, which is due to the limitations of short-axis 2D ultrasound. The same limitations do not apply to three-dimensional (3D) ultrasound, and several studies have shown 3D ultrasound to be superior to 2D ultrasound, which is unreliable for measuring twist. The aim of this study was to develop a left ventricular twisting phantom and to evaluate the accuracy of 3D STE twist measurements using different acquisition methods and volume rates (VR). This phantom was not intended to simulate a heart, but to function as a medium for ultrasound deformation measurement. The phantom was made of polyvinyl alcohol (PVA) and casted using 3D printed molds. Twist was obtained by making the phantom consist of two PVA layers with different elastic properties in a spiral pattern. This gave increased apical rotation with increased stroke volume in a mock circulation. To test the accuracy of 3D STE twist, both single-beat, as well as two, four and six multi-beat acquisitions, were recorded and compared against twist from implanted sonomicrometry crystals. A custom-made software was developed to calculate twist from sonomicrometry. The phantom gave sonomicrometer twist values from 2.0 degrees to 13.8 degrees depending on the stroke volume. STE software tracked the phantom wall well at several combinations of temporal and spatial resolution. Agreement between the two twist methods was best for multi-beat acquisitions in the range of 14.4-30.4 volumes per second (VPS), while poorer for single-beat and higher multi-beat VRs. Smallest offset was obtained at six-beat multi-beat at 17.1 VPS and 30.4 VPS. The phantom proved to be a useful tool for simulating cardiac twist and gave different twist at different stroke volumes. Best agreement with the sonomicrometer reference method was obtained at good spatial resolution (high beam density) and a relatively low VR. 3D STE twist values showed better agreement with sonomicrometry for most multi-beat recordings compared with single-beat recordings.
引用
收藏
页码:209 / 218
页数:10
相关论文
共 32 条
[1]   Left ventricular twist is load-dependent as shown in a large animal model with controlled cardiac load [J].
A'roch, Roman ;
Gustafsson, Ulf ;
Poelaert, Jan ;
Johansson, Goran ;
Haney, Michael .
CARDIOVASCULAR ULTRASOUND, 2012, 10
[2]   Apex to Base Left Ventricular Twist Mechanics Computed from High Frame Rate Two-Dimensional and Three-Dimensional Echocardiography: A Comparison Study [J].
Ashraf, Muhammad ;
Zhou, Zhiwen ;
Thuan Nguyen ;
Ashraf, Shiza ;
Sahn, David J. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2012, 25 (01) :121-128
[3]   Defining Left Ventricular Apex-to-Base Twist Mechanics Computed From High-Resolution 3D Echocardiography Validation Against Sonomicrometry [J].
Ashraf, Muhammad ;
Myronenko, Andriy ;
Nguyen, Thuan ;
Inage, Akio ;
Smith, Wayne ;
Lowe, Robert I. ;
Thiele, Karl ;
Kroeker, Carol A. Gibbons ;
Tyberg, John V. ;
Smallhorn, Jeffrey F. ;
Sahn, David J. ;
Song, Xubo .
JACC-CARDIOVASCULAR IMAGING, 2010, 3 (03) :227-234
[4]  
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
[5]   In-vivo validation of a new clinical tool to quantify three-dimensional myocardial strain using ultrasound [J].
Bouchez, S. ;
Heyde, B. ;
Barbosa, D. ;
Vandenheuvel, M. ;
Houle, H. ;
Wang, Y. ;
D'hooge, J. ;
Wouters, P. F. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2016, 32 (12) :1707-1714
[6]   Left ventricular remodeling and torsion dynamics in hypertensive patients [J].
Cameli, Matteo ;
Lisi, Matteo ;
Righini, Francesca Maria ;
Massoni, Alberto ;
Mondillo, Sergio .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (01) :79-86
[7]   New noninvasive method for assessment of left ventricular rotation - Speckle tracking echocardiography [J].
Helle-Valle, T ;
Crosby, J ;
Edvardsen, T ;
Lyseggen, E ;
Amundsen, BH ;
Smith, HJ ;
Rosen, BD ;
Lima, JAC ;
Torp, H ;
Ihlen, H ;
Smiseth, OA .
CIRCULATION, 2005, 112 (20) :3149-3156
[8]   Regional Cardiac Motion and Strain Estimation in Three-Dimensional Echocardiography: A Validation Study in Thick-Walled Univentricular Phantoms [J].
Heyde, Brecht ;
Cygan, Szymon ;
Choi, Hon Fai ;
Lesniak-Plewinska, Beata ;
Barbosa, Daniel ;
Elen, An ;
Claus, Piet ;
Loeckx, Dirk ;
Kaluzynski, Krzysztof ;
D'hooge, Jan .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (04) :668-682
[9]   ACCURACY OF REAL-TIME SINGLE- AND MULTI-BEAT 3-D SPECKLE TRACKING ECHOCARDIOGRAPHY IN VITRO [J].
Hjertaas, Johannes Just ;
Fossa, Henrik ;
Dybdahl, Grete Lunestad ;
Gruner, Renate ;
Lunde, Per ;
Matre, Knut .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (06) :1006-1014
[10]   A mock heart engineered with helical aramid fibers for in vitro cardiovascular device testing [J].
Jansen-Park, So-Hyun ;
Hsu, Po-Lin ;
Mueller, Indra ;
Steinseifer, Ulrich ;
Abel, Dirk ;
Autschbach, Ruediger ;
Rossaint, Rolf ;
Schmitz-Rode, Thomas .
BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2017, 62 (02) :139-148