What does respirator certification tell us about filtration of ultrafine particles?

被引:37
作者
Eninger, Robert M. [1 ]
Honda, Takeshi [1 ]
Reponen, Tiina [1 ]
Mckay, Roy [1 ]
Grinshpun, Sergey A. [1 ]
机构
[1] Univ Cincinnati, Dept Environm Hlth, Cincinnati, OH 45267 USA
关键词
certification; filtration; particle; respirator; ultrafine;
D O I
10.1080/15459620801960153
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Recent interest in exposures to ultrafine particles (less than 100 nm) in both environmental and occupational settings led the authors to question whether the protocols used to certify respirator filters provide adequate attention to ultrafine aerosols. The authors reviewed the particle size distribution of challenge aerosols and evaluated the aerosol measurement method currently employed in the National Institute for Occupational Safety and Health (NIOSH) particulate respirator certification protocol for its ability to measure the contribution of ultrafine particles to filter penetration. Also considered were the differences between mechanical and electrically charged (electret) filters in light of the most penetrating particle size. It was found that the sodium chloride (NaCl) and dioctylphthalate (DOP) aerosols currently used in respirator certification tests contain a significant fraction of particles in the ultrafine region. However, the photometric method deployed in the certification test is not capable of adequately measuring light scatter of particles below approximately 100 nm in diameter. Specifically, 68% (by count) and 8% (by mass) of the challenge NaCl aerosol particles and 10% (by count) and 0.3% (by mass) of the DOP particles below 100 nm do not significantly contribute to the filter penetration measurement. In addition, the most penetrating particle size for electret filters likely occurs at 100 nm or less under test conditions similar to those used in filter certification. The authors conclude, therefore, that the existing NIOSH certification protocol may not represent a worst-case assessment for electret filters because it has limited ability to determine the contribution of ultrafine aerosols, which include the most penetrating particle size for electret filters. Possible strategies to assess ultrafine particle penetration in the certification protocol are discussed.
引用
收藏
页码:286 / 295
页数:10
相关论文
共 35 条
[1]   Manikin-based performance evaluation of N95 filtering-facepiece respirators challenged with nanoparticles [J].
Balazy, A ;
Toivola, M ;
Reponen, T ;
Podgo,rski, A ;
Zimmer, A ;
Grinshpun, SA .
ANNALS OF OCCUPATIONAL HYGIENE, 2006, 50 (03) :259-269
[2]   Do N95 respirators provide 95% protection level against airborne viruses, and how adequate are surgical masks? [J].
Balazy, A ;
Toivola, M ;
Adhikari, A ;
Sivasubramani, SK ;
Reponen, T ;
Grinshpun, SA .
AMERICAN JOURNAL OF INFECTION CONTROL, 2006, 34 (02) :51-57
[3]   THE COLLECTION PERFORMANCE OF ELECTRET FILTERS IN THE PARTICLE-SIZE RANGE 10 NM-10 MU-M [J].
BAUMGARTNER, HP ;
LOFFLER, F .
JOURNAL OF AEROSOL SCIENCE, 1986, 17 (03) :438-&
[4]  
Bohren C. F., 1983, ABSORPTION SCATTERIN
[5]  
BROSSEAU LM, 1989, AM IND HYG ASSOC J, V50, P544, DOI 10.1202/0002-8894(1989)050<0544:CEORFC>2.0.CO
[6]  
2
[7]  
*CAS, 117840 CAS
[8]  
*CAS, 7647145 CAS
[9]   Light backscattering and scattering by nonspherical sea-salt aerosols [J].
Chamaillard, K ;
Jennings, SG ;
Kleefeld, C ;
Ceburnis, D ;
Yoon, YJ .
JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2003, 79 :577-597
[10]   Aerodynamic characteristics and respiratory deposition of fungal fragments [J].
Cho, SH ;
Seo, SC ;
Schmechel, D ;
Grinshpun, SA ;
Reponen, T .
ATMOSPHERIC ENVIRONMENT, 2005, 39 (30) :5454-5465