Dynamic characteristic of tall industrial chimney estimated from GPS measurement and frequency domain decomposition

被引:34
作者
Gorski, Piotr [1 ]
机构
[1] Opole Univ Technol, Fac Civil Engn & Architecture, Katowicka 48, PL-45061 Opole, Poland
关键词
Tall chimney; Full-scale measurement; GPS; Background noise; Dynamic characteristics; Frequency Domain Decomposition; MODAL IDENTIFICATION; BRIDGE; DISPLACEMENTS; FLEXIBILITY; ACCURACY;
D O I
10.1016/j.engstruct.2017.06.066
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper is concerned with the analysis of the capabilities and limitations of the use of horizontal dynamic displacements measured by the Global Positioning System (GPS) technology along a vertical profile of a tall industrial chimney under wind excitations to investigate its dynamic characteristics, i.e. the natural frequencies, mode shapes and structural damping ratios. The analysis was performed using Frequency Domain Decomposition (FDD) approach. The basic characteristics of the background noise of GPS technology are examined in the time and frequency domain based on the result of a static test. The field tests were conducted on the chimney, located in Belchatow Power Plant in Poland, using three GPS rover units. The GPS units were installed at three levels of the chimney to measure its horizontal deformation along a vertical profile due to the wind. The GPS receivers were able to measure only the first natural frequency of the chimney. The reasons of the harmful multipath and shielding effects and their influence on the reliability of the measurement results were explained. In order to mitigate the spectral leakage effects as well as to improve the accuracy of damping ratio estimation the windowing procedure was adopted with a selected number of samples L-N, determining the duration of a window function. The influence of the LN number on the damping ratio estimation was examined and suitable LN number was recommended. The dynamic characteristics of the chimney were investigated based on the dynamic wind response considered in selected directions in the horizontal plane. The obtained experimental results were compared with the predicted values derived from the finite element analysis as well as with the experimental results based on a measured tip displacement of the chimney by GPS technique using Random Decrement Method. It was shown that the structural dynamic characteristics as well as displacement monitoring of tall slender structures under wind excitations can be effectively determined based on GPS measurements at various levels along the vertical profile. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:277 / 292
页数:16
相关论文
共 46 条
  • [1] [Anonymous], 2009, P 7 ASIA PACIFIC C W
  • [2] [Anonymous], 2002, PNB032642002
  • [3] [Anonymous], 2002, CENTC250SC1 EUR
  • [4] [Anonymous], 2008, BUDOWNICTWO ARCHITEK
  • [5] [Anonymous], 2000, P 18 INT MOD AN C IM
  • [6] Bachmann H, 1991, WIEN B INFORM, V209
  • [7] Batel M, 2002, SOUND VIB, V36, P22
  • [8] Application of GPS technology to measurements of displacements of high-rise structures due to weak winds
    Breuer, P
    Chmielewski, T
    Górski, P
    Konopka, E
    [J]. JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2002, 90 (03) : 223 - 230
  • [9] The Stuttgart TV Tower - displacement of the top caused by the effects of sun and wind
    Breuer, Peter
    Chmielewski, Tadeusz
    Gorski, Piotr
    Konopka, Eduard
    Tarczynski, Leslaw
    [J]. ENGINEERING STRUCTURES, 2008, 30 (10) : 2771 - 2781
  • [10] Brincker R, 2001, P SOC PHOTO-OPT INS, V4359, P698