Circumferential pulmonary vein antrum ablation for the treatment of paroxysmal atrial fibrillation: A randomized controlled trial

被引:6
作者
Xu, Qiang [1 ,2 ]
Ju, Weizhu [1 ]
Xiao, Fangyi [1 ]
Yang, Bing [1 ]
Chen, Hongwu [1 ]
Yang, Gang [1 ]
Zhang, Fengxiang [1 ]
Gu, Kai [1 ]
Li, Mingfang [1 ]
Wang, Daowu [3 ]
Chen, Minglong [1 ]
机构
[1] Nanjing Med Univ, Dept Cardiol, Affiliated Hosp 1, Nanjing, Peoples R China
[2] Zhejiang Prov Peoples Hosp, Dept Cardiol, Hangzhou, Zhejiang, Peoples R China
[3] Nanjing Med Univ, Heart & Lung Inst, Affiliated Hosp 1, Nanjing, Peoples R China
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2020年 / 43卷 / 03期
关键词
catheter ablation; contact force; paroxysmal atrial fibrillation; pulmonary vein antrum modification; pulmonary vein isolation; RADIOFREQUENCY CATHETER ABLATION; CONTACT FORCE; LESION SIZE; STEAM POP; MODEL; CONDUCTION;
D O I
10.1111/pace.13863
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background It remains unclear whether the curative result of paroxysmal atrial fibrillation (PAF) is a result of pulmonary vein (PV) isolation, PV antrum modification (PVAM), or both. We hypothesized that sufficient antrum modification (PVAM) is as important as PV isolation (PVI) for atrial fibrillation (AF) control and that PVAM can be evaluated by quantified lesion deployment using a force-sensing catheter. Methods and Results Patients of symptomatic PAF were randomly assigned 2:1 into a PVAM group or a circumferential PV isolation (CPVI) group. In the PVAM group, circumferential quantitative ablation evaluated by automatical VisiTag module was performed. In the CPVI group, conventional circumferential ablation was performed to achieve the end point of all-PV isolation. In total, 180 patients with PAF were enrolled and randomly assigned to either the PVAM group (n = 120) or the CPVI group (n = 60). A total of 179 patients successfully underwent ablation. In the PVAM group, 68 patients achieved all PVI (PVAM-PVI), while 51 did not (PVAM-non-PVI). At 18 months, there was no significant difference in the maintenance of sinus rhythm between the PVAM and CPVI groups (84.9 vs 79.7%, P = .382). The PVAM-PVI subgroup demonstrated a higher arrhythmia-free survival compared with the PVAM-non-PVI subgroup (92.6 vs 74.5%, P = .006) and the CPVI group (92.6 vs 79.7%, P = .036). Conclusions The trial shows that sufficient force-sensing guided PVAM can result in satisfying outcomes in PAF patients. Notably, sufficient PVAM with all-PV isolated will further increase the success rate.
引用
收藏
页码:280 / 288
页数:9
相关论文
共 30 条
[1]   HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: Recommendations for personnel, policy, procedures and follow-up [J].
Calkins, Hugh ;
Brugada, Josep ;
Packer, Douglas L. ;
Cappato, Riccardo ;
Chen, Shih-Ann ;
Crijns, Harry J. G. ;
Damiano, Ralph J., Jr. ;
Davies, D. Wyn ;
Haines, David E. ;
Haissaguerre, Michel ;
Iesaka, Yoshito ;
Jackman, Warren ;
Jais, Pierre ;
Kottkamp, Hans ;
Kuck, Karl Heinz ;
Lindsay, Bruce D. ;
Marchlinski, Francis E. ;
McCarthy, Patrick M. ;
Mont, J. Lluis ;
Morady, Fred ;
Nademanee, Koontawee ;
Natale, Andrea ;
Pappone, Carlo ;
Prystowsky, Eric ;
Raviele, Antonio ;
Ruskin, Jeremy N. ;
Shemin, Richard J. .
HEART RHYTHM, 2007, 4 (06) :816-861
[2]  
Calkins H, 2012, HEART RHYTHM, V9, P632, DOI 10.1016/j.hrthm.2011.12.016
[3]   Radiofrequency Catheter Ablation of Atrial Fibrillation: A Cause of Silent Thromboembolism? Magnetic Resonance Imaging Assessment of Cerebral Thromboembolism in Patients Undergoing Ablation of Atrial Fibrillation [J].
Gaita, Fiorenzo ;
Caponi, Domenico ;
Pianelli, Martina ;
Scaglione, Marco ;
Toso, Elisabetta ;
Cesarani, Federico ;
Boffano, Carlo ;
Gandini, Giovanni ;
Valentini, Maria Consuelo ;
De Ponti, Roberto ;
Halimi, Franck ;
Leclercq, Jean Francois .
CIRCULATION, 2010, 122 (17) :1667-1673
[4]   Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins [J].
Haïssaguerre, M ;
Jaïs, P ;
Shah, DC ;
Takahashi, A ;
Hocini, M ;
Quiniou, G ;
Garrigue, S ;
Le Mouroux, A ;
Le Métayer, P ;
Clémenty, J .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (10) :659-666
[5]   Electrophysiological breakthroughs from the left atrium to the pulmonary veins [J].
Haïssaguerre, M ;
Shah, DC ;
Jaïs, P ;
Hocini, M ;
Yamane, T ;
Deisenhofer, I ;
Chauvin, M ;
Garrigue, S ;
Clémenty, J .
CIRCULATION, 2000, 102 (20) :2463-2465
[6]   Persistent Atrial Fibrillation Ablation With or Without Contact Force Sensing [J].
Hussein, Ayman A. ;
Barakat, Amr F. ;
Saliba, Walid I. ;
Tarakji, Khaldoun G. ;
Bassiouny, Mohamed ;
Baranowski, Bryan ;
Tchou, Patrick ;
Bhargava, Mandeep ;
Dresing, Thomas ;
Callahan, Thomas ;
Cantillon, Daniel ;
Kanj, Mohamed ;
Lindsay, Bruce D. ;
Wazni, Oussama M. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2017, 28 (05) :483-488
[7]   Relationship Between Catheter Contact Force and Radiofrequency Lesion Size and Incidence of Steam Pop in the Beating Canine Heart Electrogram Amplitude, Impedance, and Electrode Temperature Are Poor Predictors of Electrode-Tissue Contact Force and Lesion Size [J].
Ikeda, Atsushi ;
Nakagawa, Hiroshi ;
Lambert, Hendrik ;
Shah, Dipen C. ;
Fonck, Edouard ;
Yulzari, Aude ;
Sharma, Tushar ;
Pitha, Jan V. ;
Lazzara, Ralph ;
Jackman, Warren M. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2014, 7 (06) :1174-1180
[8]   Incidence of pulmonary vein conduction recovery in patients without clinical recurrence after ablation of paroxysmal atrial fibrillation: Mechanistic implications [J].
Jiang, Ru-hong ;
Po, Sunny S. ;
Tung, Roderick ;
Liu, Qiang ;
Sheng, Xia ;
Zhang, Zu-wen ;
Sun, Ya-xun ;
Yu, Lu ;
Zhang, Pei ;
Fu, Guo-sheng ;
Jiang, Chen-yang .
HEART RHYTHM, 2014, 11 (06) :969-976
[9]   Adenosine triphosphate-guided pulmonary vein isolation for atrial fibrillation: the UNmasking Dormant Electrical Reconduction by Adenosine TriPhosphate (UNDER-ATP) trial [J].
Kobori, Atsushi ;
Shizuta, Satoshi ;
Inoue, Koichi ;
Kaitani, Kazuaki ;
Morimoto, Takeshi ;
Nakazawa, Yuko ;
Ozawa, Tomoya ;
Kurotobi, Toshiya ;
Morishima, Itsuro ;
Miura, Fumiharu ;
Watanabe, Tetsuya ;
Masuda, Masaharu ;
Naito, Masaki ;
Fujimoto, Hajime ;
Nishida, Taku ;
Furukawa, Yoshio ;
Shirayama, Takeshi ;
Tanaka, Mariko ;
Okajima, Katsunori ;
Yao, Takenori ;
Egami, Yasuyuki ;
Satomi, Kazuhiro ;
Noda, Takashi ;
Miyamoto, Koji ;
Haruna, Tetsuya ;
Kawaji, Tetsuma ;
Yoshizawa, Takashi ;
Toyota, Toshiaki ;
Yahata, Mitsuhiko ;
Nakai, Kentaro ;
Sugiyama, Hiroaki ;
Higashi, Yukei ;
Ito, Makoto ;
Horie, Minoru ;
Kusano, Kengo F. ;
Shimizu, Wataru ;
Kamakura, Shiro ;
Kimura, Takeshi .
EUROPEAN HEART JOURNAL, 2015, 36 (46) :3276-3287
[10]   Impact of Complete Versus Incomplete Circumferential Lines Around the Pulmonary Veins During Catheter Ablation of Paroxysmal Atrial Fibrillation Results From the Gap-Atrial Fibrillation-German Atrial Fibrillation Competence Network 1 Trial [J].
Kuck, Karl-Heinz ;
Hoffmann, Boris A. ;
Ernst, Sabine ;
Wegscheider, Karl ;
Treszl, Andras ;
Metzner, Andreas ;
Eckardt, Lars ;
Lewalter, Thorsten ;
Breithardt, Guenter ;
Willems, Stephan .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2016, 9 (01)