Development of the analog ASIC for multi-channel readout X-ray CCD camera

被引:0
|
作者
Nakajima, Hiroshi [1 ]
Matsuura, Daisuke [2 ]
Idehara, Toshihiro [2 ]
Anabuki, Naohisa [1 ]
Tsunemi, Hiroshi [1 ]
Doty, John P. [3 ]
Ikeda, Hirokazu [4 ]
Katayama, Haruyoshi [5 ]
Kitamura, Hisashi [6 ]
Uchihori, Yukio [6 ]
机构
[1] Osaka Univ, Grad Sch Sci, Dept Earth & Space Sci, Osaka 5600043, Japan
[2] Mitsubishi Heavy Ind Co Ltd, Dept Space & Integrated Def Syst, Aichi 4858561, Japan
[3] Noqsi Aerosp Ltd, Pine, CO 80470 USA
[4] Japan Aerosp Explorat Agcy, Inst Space & Astronaut Sci, Chuo Ku, Kanagawa 2525210, Japan
[5] Japan Aerosp Explorat Agcy, Tsukuba Space Ctr, Earth Observat Res Ctr, Tsukuba, Ibaraki 3058505, Japan
[6] Natl Inst Radiol Sci, Inage Ku, Chiba 2638555, Japan
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2011年 / 632卷 / 01期
关键词
X-ray; ASIC; CCD camera; PERFORMANCE; NOISE;
D O I
10.1016/j.nima.2010.12.174
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We report on the performance of an analog application-specific integrated circuit (ASIC) developed aiming for the front-end electronics of the X-ray CCD camera system onboard the next X-ray astronomical satellite, ASTRO-H. It has four identical channels that simultaneously process the CCD signals. Distinctive capability of analog-to-digital conversion enables us to construct a CCD camera body that outputs only digital signals. As the result of the front-end electronics test, it works properly with low input noise of <= 30 mu V at the pixel rate below 100 kHz. The power consumption is sufficiently low of similar to 150 mW/chip. The input signal range of +/- 20 mV covers the effective energy range of the typical X-ray photon counting CCD (up to 20 key). The integrated non-linearity is 0.2% that is similar as those of the conventional CCDs in orbit. We also performed a radiation tolerance test against the total ionizing dose (TID) effect and the single event effect. The irradiation test using Co-60 and proton beam showed that the ASIC has the sufficient tolerance against TID up to 200 krad, which absolutely exceeds the expected amount of dose during the period of operating in a low-inclination low-earth orbit. The irradiation of Fe ions with the fluence of 5.2 x 10(8) lon/cm(2) resulted in no single event latchup (SEL), although there were some possible single event upsets. The threshold against SEL is higher than 1.68 MeV cm(2)/mg, which is sufficiently high enough that the SEL event should not be one of major causes of instrument downtime in orbit. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:128 / 132
页数:5
相关论文
共 50 条
  • [21] Characterization of multichannel SDD X-ray spectrometer with ASIC readout
    Singh, Nishant
    Shanmugam, M.
    Patel, Arpit
    Kumar, Sushil
    Painkra, Deepak K.
    Ladiya, Tinkal
    Vadawale, S.
    ADVANCES IN SPACE RESEARCH, 2025, 75 (07) : 5630 - 5639
  • [22] Stacked, filtered multi-channel X-ray diode array
    MacNeil, L. P.
    Dutra, E. C.
    Compton, S. M.
    Jacoby, B. A.
    Raphaelian, M. L.
    RADIATION DETECTORS: SYSTEMS AND APPLICATIONS XVI, 2015, 9595
  • [23] Laboratory X-ray CCD camera electronics - a test bed for the Swift X-ray Telescope
    Hill, JE
    Zugger, ME
    Shoemaker, J
    Witherite, ME
    Koch, S
    Chou, L
    Case, T
    Burrows, DN
    X-RAY AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY XI, 2000, 4140 : 87 - 98
  • [24] Development of a 32-channel ASIC for an X-ray APD detector onboard the ISS
    Arimoto, Makoto
    Harita, Shohei
    Sugita, Satoshi
    Yatsu, Yoichi
    Kawai, Nobuyuki
    Ikeda, Hirokazu
    Tomida, Hiroshi
    Isobe, Naoki
    Ueno, Shiro
    Mihara, Tatehiro
    Serino, Motoko
    Kohmura, Takayoshi
    Sakamoto, Takanori
    Yoshida, Atsumasa
    Tsunemi, Hiroshi
    Hatori, Satoshi
    Kume, Kyo
    Hasegawa, Takashi
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 882 : 138 - 147
  • [25] Proximal ADMM for Multi-Channel Image Reconstruction in Spectral X-ray CT
    Sawatzky, Alex
    Xu, Qiaofeng
    Schirra, Carsten O.
    Anastasio, Mark A.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (08) : 1657 - 1668
  • [26] A multi-spectral analog photon counting readout circuit for X-ray hybrid pixel detectors
    Perenzoni, Matteo
    Stoppa, David
    Malfatti, Mattia
    Simoni, Andrea
    2006 IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE PROCEEDINGS, VOLS 1-5, 2006, : 2003 - +
  • [27] Studies of an X-ray imaging detector based on THGEM and CCD camera
    Peng, Zhi-Yuan
    Gu, Yung-Ting
    Xie, Yu-Guang
    Yan, Wen-Qi
    Zhao, Hang
    Li, Geng-Lan
    Jiang, Jie-Chen
    Feng, Huan-Bo
    Wang, Zhi-Gang
    Lv, Jun-Guang
    Hu, Tao
    Zhou, Li
    RADIATION DETECTION TECHNOLOGY AND METHODS, 2018, 2 (01)
  • [28] The AGIPD 1.0 ASIC: Random access High Frame Rate, High Dynamic Range X-Ray Camera Readout for the European XFEL
    Allahgholi, A.
    Becker, J.
    Bianco, L.
    Delfs, A.
    Arino-Estrada, G.
    Goettlicher, P.
    Graafsma, H.
    Hirsemann, H.
    Jack, S.
    Klyuev, A.
    Lange, S.
    Marras, A.
    Poehlsen, J.
    Sheviakov, I.
    Trunk, U.
    Xia, Q.
    Zhang, J.
    Zimmer, M.
    Dinapoli, R.
    Greiffenberg, D.
    Mezza, D.
    Mozzanica, A.
    Schmitt, B.
    Shi, X.
    Klanner, R.
    Schwandt, J.
    Krueger, H.
    Rah, S.
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [29] MCRC V1 Development of integrated readout electronics for next generation X-ray CCD detectors for future satellite observatories
    Herrmann, Sven
    Wong, Josephine
    Chattopadhyay, Tanmoy
    Morris, R. Glenn
    Burke, Barry
    Prigozhin, Gregory
    Cooper, Mike
    Craig, David
    Donlon, Kevan
    Foster, Richard
    Malonis, Andrew
    Bautz, Mark
    Allen, Steven
    X-RAY, OPTICAL, AND INFRARED DETECTORS FOR ASTRONOMY IX, 2020, 11454
  • [30] Flight CCD selection for the X-ray CCD camera of the monitor of All-sky X-ray image mission onboard the international space station
    Miyata, E
    Kamiyama, D
    Kouno, H
    Nemesh, N
    Tomida, H
    Katayama, H
    Tsunemi, H
    Matsuoka, M
    X-RAY AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY XIII, 2004, 5165 : 366 - 374