Microstructural and mechanical characteristics of low alloyed Ni-Mo-Cu austempered ductile iron

被引:19
作者
Bosnjak, B
Radulovic, B
Pop-Tonev, K
Asanovic, V
机构
[1] Univ Montenegro, Dept Met & Technol, YU-81000 Podgorica, Yugoslavia
[2] Univ Rudjer Boskovic, Dept Met & Technol, Skopje 91000, North Macedonia
关键词
austempered ductile iron; retained austenite; bainite;
D O I
10.2355/isijinternational.40.1246
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
The present study investigated the effect of austempering temperature and austempering time on the microstructure and mechanical properties of low alloyed Ni-Mo-Cu ductile iron. The effect of austempering parameters and alloying additions on the austemperability of treated ductile iron has been estimated, too. Specimens were austenitised at 900 degreesC for 120 min, then austempered for 10, 30, 60, 120, 240 and 360 min at 300, 350 and 400 degreesC respectively, and examined by light and scanning electron microscopy. The structure consisted of bainitic ferrite containing retained austenite, the amount of which increased, and the carbon content of which decreased, with increasing austempering temperature. The carbon content of austenite has been evaluated by measuring the lattice parameter by X-ray diffraction. After short periods of austempering time in iron, the carbon content of the retained austenite decreases and on subsequent cooling to room temperature it transforms to martensite. The volume fractions of retained austenite, bainitic ferrite, martensite and austenite carbon content was correlated with microstructural changes and mechanical properties. Optimum properties are obtained at intermediate austempering periods (120-240 min) when both the amount of retained austenite and austenite carbon content are maximum.
引用
收藏
页码:1246 / 1252
页数:7
相关论文
共 50 条
  • [1] Study of the effects of austempering temperature and time on scuffing behavior of austempered Ni-Mo-Cu ductile iron
    Han, J. M.
    Zou, Q.
    Barber, G. C.
    Nasir, T.
    Northwood, D. O.
    Sun, X. C.
    Seaton, P.
    WEAR, 2012, 290 : 99 - 105
  • [2] Ni-Cu Alloyed Austempered Ductile Iron Resistance to Multifactorial Wear
    Wieczorek, Andrzej Norbert
    LUBRICANTS, 2024, 12 (04)
  • [3] Microstructural characteristics of Al-alloyed austempered ductile irons
    Kiani-Rashid, A. R.
    Edmonds, D. V.
    JOURNAL OF ALLOYS AND COMPOUNDS, 2009, 477 (1-2) : 391 - 398
  • [4] The mechanical properties of a low alloyed austempered ductile iron in the upper ausferrite region
    Wen, DC
    Lei, TS
    ISIJ INTERNATIONAL, 1999, 39 (05) : 493 - 500
  • [5] Wear behavior of an austempered ductile iron containing Mo-Ni-Cu
    Yazdani, S
    Rahimi, MA
    PRICM 5: THE FIFTH PACIFIC RIM INTERNATIONAL CONFERENCE ON ADVANCED MATERIALS AND PROCESSING, PTS 1-5, 2005, 475-479 : 199 - 202
  • [6] Dry sliding wear of Ni alloyed austempered ductile iron
    Chiniforush, E. Akbarzadeh
    Rahimi, M. A.
    Yazdani, S.
    CHINA FOUNDRY, 2016, 13 (05) : 361 - 367
  • [7] Dry sliding wear of Ni alloyed austempered ductile iron
    E. Akbarzadeh Chiniforush
    M. A. Rahimi
    S. Yazdani
    China Foundry, 2016, 13 : 361 - 367
  • [8] Wear Performance of Cu-Alloyed Austempered Ductile Iron
    Batra, Uma
    Batra, Nimish
    Sharma, J. D.
    JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2013, 22 (04) : 1136 - 1142
  • [9] Microstructural and mechanical property modelling of austempered ductile iron
    Putman, DC
    Thomson, RC
    INTERNATIONAL JOURNAL OF CAST METALS RESEARCH, 2003, 16 (1-3) : 191 - 196
  • [10] Dry sliding wear of Ni alloyed austempered ductile iron
    E.Akbarzadeh Chiniforush
    M.A.Rahimi
    S.Yazdani
    China Foundry, 2016, 13 (05) : 361 - 367