Using 7.5 frames per second reduces radiation exposure in lower extremity peripheral vascular interventions

被引:2
作者
Akkus, Nuri I. [1 ]
Mina, George S. [2 ]
Abdulbaki, Abdulrahman [1 ]
Shafiei, Fereidoon [1 ]
Tandon, Neeraj [3 ]
机构
[1] LSU Hlth Sci Ctr Shreveport, Dept Cardiol, Shreveport, LA 71130 USA
[2] LSU Hlth Sci Ctr Shreveport, Dept Med, Shreveport, LA 71130 USA
[3] Overton Brooks VA Med Ctr, Shreveport, LA USA
关键词
7.5 Frame rate; peripheral arterial disease; radiation dose; SKIN INJURIES; PATIENT; FLUOROSCOPY; SAFETY;
D O I
10.1177/1708538114549592
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background Peripheral vascular interventions can be associated with significant radiation exposure to the patient and the operator. Objective In this study, we sought to compare the radiation dose between peripheral vascular interventions using fluoroscopy frame rate of 7.5 frames per second (fps) and those performed at the standard 15 fps and procedural outcomes. Methods We retrospectively collected data from consecutive 87 peripheral vascular interventions performed during 2011 and 2012 from two medical centers. The patients were divided into two groups based on fluoroscopy frame rate; 7.5 fps (group A, n=44) and 15 fps (group B, n=43). We compared the demographic, clinical, procedural characteristics/outcomes, and radiation dose between the two groups. Radiation dose was measured as dose area product in micro Gray per meter square. Results Median dose area product was significantly lower in group A (3358, interquartile range (IQR) 2052-7394) when compared to group B (8812, IQR 4944-17,370), p<0.001 with no change in median fluoroscopy time in minutes (18.7, IQR 11.1-31.5 vs. 15.7, IQR 10.1-24.1), p=0.156 or success rate (93.2% vs. 95.3%), p>0.999. Conclusion Using fluoroscopy at the rate of 7.5 fps during peripheral vascular interventions is associated with lower radiation dose compared to the standard 15 fps with comparable success rate without associated increase in the fluoroscopy time or the amount of the contrast used. Therefore, using fluoroscopy at the rate of 7.5 fps should be considered in peripheral vascular interventions.
引用
收藏
页码:240 / 244
页数:5
相关论文
共 16 条
[1]  
[Anonymous], 1990, IMPL PRINC LOW REAS
[2]  
[Anonymous], 2008, B COMM RADIAT PROT, V56, P1
[3]   Radiation Safety Program for the Cardiac Catheterization Laboratory [J].
Chambers, Charles E. ;
Fetterly, Kenneth A. ;
Holzer, Ralf ;
Lin, Pei-Jan Paul ;
Blankenship, James C. ;
Balter, Stephen ;
Laskey, Warren K. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2011, 77 (04) :546-556
[4]   Radiation dose to patients from cardiac diagnostic imaging [J].
Einstein, Andrew J. ;
Moser, Kevin W. ;
Thompson, Randall C. ;
Cerqueira, Manuel D. ;
Henzlova, Milena J. .
CIRCULATION, 2007, 116 (11) :1290-1305
[5]  
FDA Public Health Advisory, 1994, AV SER XRAY IND SKIN
[6]   Patient Radiation Exposure in a Modern, Large-Volume, Pediatric Cardiac Catheterization Laboratory [J].
Glatz, Andrew C. ;
Patel, Akash ;
Zhu, Xiaowei ;
Dori, Yoav ;
Hanna, Brian D. ;
Gillespie, Matthew J. ;
Rome, Jonathan J. .
PEDIATRIC CARDIOLOGY, 2014, 35 (05) :870-878
[7]   ACCF/AHA/HRS/SCAI clinical competence statement on physician knowledge to optimize patient safety and image quality in fluoroscopically guided invasive cardiovascular procedures - A report of the American College of Cardiology Foundation/American Heart Association/American College of Physicians Task Force on Clinical Competence and Training [J].
Hirshfeld, JW ;
Balter, SD ;
Brinker, JA ;
Kern, MJ ;
Klein, LW ;
Lindsay, BD ;
Tommaso, CL ;
Tracy, CM ;
Wagner, LK .
CIRCULATION, 2005, 111 (04) :511-532
[8]   Skin injuries from fluoroscopically guided procedures: part I, Characteristics of radiation injury [J].
Koenig, TR ;
Wolff, D ;
Mettler, FA ;
Wagner, LK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (01) :3-11
[9]   The AAPM/RSNA physics tutorial for residents - Fluoroscopy: Patient radiation exposure issues [J].
Mahesh, M .
RADIOGRAPHICS, 2001, 21 (04) :1033-1045
[10]   Minimizing radiation-induced skin injury in interventional radiology procedures [J].
Miller, DL ;
Balter, S ;
Noonan, PT ;
Georgia, JD .
RADIOLOGY, 2002, 225 (02) :329-336