Indoor air performance and irreversibility analysis of a slot-ventilated mechanical system with wall heater and thermosolutal exchanger

被引:5
作者
Gupta, Neha [1 ]
Nayak, A. K. [1 ]
机构
[1] Indian Inst Technol Roorkee, Dept Math, Roorkee 247667, Uttar Pradesh, India
关键词
Slot-Ventilated enclosure; Entropy generation; Performance evaluation criterion; Average temperature; Air change per hour; AIRBORNE POLLUTANT REMOVALS; MIXED CONVECTION; ENTROPY GENERATION; PARAMETRIC INVESTIGATIONS; ENCLOSURE; FLOW; CAVITY; SIMULATION; NANOFLUID; INLET;
D O I
10.1016/j.enbuild.2019.109344
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A numerical simulation is performed for fluid flow, heat and mass transfer in a slot-ventilated enclosure to optimize the removal rate of heat and contaminants due to wall heater and a thermosolutal exchanger. Cold fresh air is infiltrated through the inlet port located along right vertical wall and flush out through the chimney shaped outlet port located along the upper wall. Vertical walls of the chimney are considered to be inclined at different angles with horizontal axis. Two dimensional analysis is made for flow, temperature and concentration in terms of streamlines, isotherms and isoconcentrations with the variation of Richardson number (Ri) from 0.0 to 10.0, Reynolds number (Re) from 50 to 300 and inclination angle of chimney (45 degrees <= delta <= 90 degrees) with the fixed value of Prandtl number (Pr = 0.71) and Schmidt number (Sc = 1.14). The impact of inlet port locations, Reynolds number, inclination angle and Richardson number on average rate of heat transfer and mass transfer, average temperature, entropy generation, Bejan number, cooling efficiency, air change per hour and performance evaluation criterion inside the system is evaluated. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页数:19
相关论文
共 23 条
[1]  
Aouachria Z., 2015, PROGR CLEAN ENERGY, V1, P433, DOI [10.1007/978-3-319-16709-131, DOI 10.1007/978-3-319-16709-131]
[2]   Effect of solar chimney inclination angle on space flow pattern and ventilation rate [J].
Bassiouny, Ramadan ;
Korah, Nader S. A. .
ENERGY AND BUILDINGS, 2009, 41 (02) :190-196
[3]   Fluid, heat and contaminant transport structures of laminar double-diffusive mixed convection in a two-dimensional ventilated enclosure [J].
Deng, QH ;
Zhou, JM ;
Mei, C ;
Shen, YM .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2004, 47 (24) :5257-5269
[4]   NATURE OF VERTICAL NATURAL CONVECTION FLOWS RESULTING FROM COMBINED BUOYANCY EFFECTS OF THERMAL AND MASS DIFFUSION [J].
GEBHART, B ;
PERA, L .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1971, 14 (12) :2025-&
[5]   Numerical simulation of three-dimensional double diffusive free convection flow and irreversibility studies in a solar distiller [J].
Ghachem, Kaouther ;
Kolsi, Lioua ;
Maatki, Chamseddine ;
Hussein, Ahmed Kadhim ;
Borjini, Mohamed Naceur .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2012, 39 (06) :869-876
[6]  
Gualtieri C, 2017, FLUIDS, V2, DOI 10.3390/fluids2020017
[7]   Effects of Heat-Induced Pollutants due to Thermosolutal Exchanger in Ventilation System [J].
Gupta, Neha ;
Nayak, Ameeya Kumar .
JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2018, 32 (01) :172-183
[8]   A numerical investigation of buoyancy induced turbulent air flow in an inclined passive wall solar chimney for natural ventilation [J].
Khanal, Rakesh ;
Lei, Chengwang .
ENERGY AND BUILDINGS, 2015, 93 :217-226
[9]   Numerical investigation of turbulent mixed convection in an open cavity: Effect of inlet and outlet openings [J].
Koufi, Lounes ;
Younsi, Zohir ;
Cherif, Yassine ;
Naji, Hassane .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2017, 116 :103-117
[10]  
Lewandowski A, 1996, ENTROPY GENERATION M