Measurements of household electricity and domestic hot water use in dwellings and the effect of different monitoring time resolution

被引:31
作者
Bagge, Hans [1 ]
Johansson, Dennis [1 ,2 ]
机构
[1] Lund Univ, Lund, Sweden
[2] Swegon AB, Tomelilla, Sweden
关键词
Household electricity; Domestic hot water; Energy use; Monitoring; PATTERNS;
D O I
10.1016/j.energy.2011.02.037
中图分类号
O414.1 [热力学];
学科分类号
摘要
The use of household electricity and domestic hot water has been measured for 72 apartments in an apartment building located in the south of Sweden. The measurements were carried out with samples every 6 s, a tenfold increase in resolution compared to available published data, during a measurement period of five days, in the winter season, including a weekend. The influence of the time resolution on the distribution of data was analysed by integrating the 6 s data to represent longer logging intervals. Extreme values, especially the high values, are shown to be reduced if the time interval is increased. The maximum household electric power was 50% higher at a 6 s resolution compared to 60 s and the corresponding difference for domestic hot water flow was 40%. Daily variations has to be considered for photovoltaic installations and solar thermal collectors, energy simulations of buildings need at least hourly data and all kind of power design in a building or its services benefits from much more resolved data. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2943 / 2951
页数:9
相关论文
共 23 条
[1]  
Bagge H., 2007, ENERGY USE MULTIFAMI
[2]  
BAGGE H, 2006, BYGG TEKNIK, V8, P61
[3]  
Bagge H., 2008, P BUILD PHYS S 2008, P95
[4]  
BAGGE H, 2009, P 5 NORD C CONSTR EC, P1
[5]   A BOTTOM-UP APPROACH TO RESIDENTIAL LOAD MODELING [J].
CAPASSO, A ;
GRATTIERI, W ;
LAMEDICA, R ;
PRUDENZI, A .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1994, 9 (02) :957-964
[6]  
Elmroth A., 2005, ACTION SUSTAINABILIT, P498
[7]  
GRANROTH M, 2008, VATTEN AVLOPP BYGGVA, V10
[8]  
Harderup E., 1995, KLIMATDATA FUKTBERAK
[9]  
JOHANSSON D, 2011, J BUILDING PERFORM S
[10]  
Johansson D., 2002, P 6 BUILD PHYS S TRO, P889