Comparison of the four formulas of adjusting QT interval for the heart rate in the middle-aged healthy Turkish men

被引:28
作者
Dogan, A
Tunc, E
Varol, E
Ozaydin, M
Ozturk, M
机构
[1] Suleyman Demirel Univ, Sch Med, Dept Cardiol, Isparta, Turkey
[2] Suleyman Demirel Univ, Sch Med, Dept Internal Med, Isparta, Turkey
[3] Suleyman Demirel Univ, Sch Med, Dept Publ Hlth, Isparta, Turkey
[4] Publ Hosp, Isparta, Turkey
关键词
QT interval; heart rate; correction method;
D O I
10.1111/j.1542-474X.2005.05604.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The aim of this study was to evaluate the QT intervals at different rest heart rates in healthy middle-aged Turkish men and to compare the known four QT adjusting methods for heart rate. Methods and Results: The QT intervals were measured in electrocardiograms of 210 healthy men (mean age = 35-60 years). A curve relating QT intervals and heart rates from 45 to 135 beats/min was constructed for study population. Based on the formula of Bazett, Fridericia, and Framingham, adjusted QT intervals in these range of heart rates were separately estimated. An adjusting nomogram for different heart rates was created using a reference value, which was the measured QT interval at heart rate of 60 beats/min (QT(NO) = QT + correcting number). These four QT correction methods were compared with each other. The reference value of QT interval at heart rate of 60 beats/min was 382 ms. The relationship between QT and RR interval was linear (r = 0.66, P 0.001). Nomogram method corrected QT interval most accurately for all the heart rates compared with other three adjusting methods. At heart rates of 60-100 beats/min, the equation of linear regression was QT = 237 + 0.158 x RR (P < 0.001). Bazett's formula gave the poorest results at all the heart rates. The formulas of Fridericia and Framingham were superior to Bazett's formula; however, they overestimated QT interval at heart rate of 60-110 beats/min (P < 0.01). At lower rates (< 60 beats/mim, all methods except nomogram method, underestimated QT interval (P = 0.03). Conclusion: Among four QT correction formulas, the nomogram method provides the most accurately adjusted values of QT interval for all the heart rates in healthy men. Bazett's formula fails to adjust the QT interval for all the heart rates.
引用
收藏
页码:134 / 141
页数:8
相关论文
共 21 条
[1]  
[Anonymous], 1997, CARDIAC ELECTROPHYSI
[2]   QT-RR relationship in healthy subjects exhibits substantial intersubject variability and high intrasubject stability [J].
Batchvarov, VN ;
Ghuran, A ;
Smetana, P ;
Hnatkova, K ;
Harries, M ;
Dilaveris, P ;
Camm, AJ ;
Malik, M .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2002, 282 (06) :H2356-H2363
[3]  
Bazett HC, 1920, HEART-J STUD CIRC, V7, P353
[4]  
BEXTON RS, 1986, BRIT HEART J, V55, P253
[5]  
Copie X., 1998, Annals of Noninvasive Electrocardiology, V3, P38, DOI 10.1111/j.1542-474X.1998.tb00028.x
[6]   A new physiological method for heart rate correction of the QT interval [J].
Davey, P .
HEART, 1999, 82 (02) :183-186
[7]   The prognostic value of the QT interval and QT interval dispersion in all-cause and cardiac mortality and morbidity in a population of Danish citizens [J].
Elming, H ;
Holm, E ;
Jun, L ;
Torp-Pedersen, C ;
Kober, L ;
Kircshoff, M ;
Malik, M ;
Camm, J .
EUROPEAN HEART JOURNAL, 1998, 19 (09) :1391-1400
[8]  
Fridericia LS., 1920, Acta Med Scand, V53, P469, DOI DOI 10.1111/J.0954-6820.1920.TB18266.X
[9]   RELATION BETWEEN QT INTERVALS AND HEART-RATES FROM 40 TO 120 BEATS/MIN IN REST ELECTROCARDIOGRAMS OF MEN AND A SIMPLE METHOD TO ADJUST QT INTERVAL VALUES [J].
KARJALAINEN, J ;
VIITASALO, M ;
MANTTARI, M ;
MANNINEN, V .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (07) :1547-1553
[10]  
Kautzner Josef, 2002, Card Electrophysiol Rev, V6, P273, DOI 10.1023/A:1016389227576