Morphometry of the Trabecular Meshwork In Vivo in a Healthy Population Using Fourier-Domain Optical Coherence Tomography

被引:36
|
作者
Fernandez-Vigo, Jose I. [1 ,2 ]
Garcia-Feijoo, Julian [1 ]
Martinez-de-la-Casa, Jose M. [1 ]
Garcia-Bella, Javier [1 ]
Fernandez-Vigo, Jose A. [2 ,3 ]
机构
[1] Univ Complutense Madrid, Inst Hlth Res, Clin San Carlos Univ Hosp, Dept Ophthalmol, Madrid, Spain
[2] Int Ctr Adv Ophthalmol, Madrid, Spain
[3] Univ Extremadura, Dept Ophthalmol, Badajoz, Spain
关键词
trabecular meshwork; optical coherence tomography; glaucoma anterior segment; ANTERIOR-CHAMBER ANGLE; ULTRASOUND BIOMICROSCOPY; IRIDOCORNEAL ANGLE; SEGMENT; REPRODUCIBILITY; IDENTIFICATION; PARAMETERS;
D O I
10.1167/iovs.14-16154
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. We measured the length, thickness, and area of the trabecular meshwork (TM) in vivo using Fourier domain optical coherence tomography (FD-OCT) in a Caucasian population of healthy subjects. METHODS. A cross-sectional study was done of 1006 healthy subjects. Left eyes were randomly selected. Age, sex, IOP, and spherical refractive error were noted. The depth and volume of the anterior chamber and the central corneal thickness were measured with Pentacam, while IOL Master was used to measure the axial length. The length, thickness, and area of the TM were measured through FD-OCT RTVue. A study was done to determine the correlation between TM size, and other demographic and ocular parameters. Finally, the reproducibility of the measurements was assessed for a subgroup of 50 eyes from 50 patients. RESULTS. We were able to measure the TM in 91.1% of the total eyes studied. The mean TM length was 496.99 +/- 92.77 mu m (range, 275-800), TM thickness was 174.16 +/- 28.14 mu m (range, 100-276), and TM area was 0.069 +/- 0.031 mm(2) (range, 0.023-0.133). No differences were found in terms of length and area for sex, although the TM was slightly thicker in men (P = 0.046). No correlation was observed between the TM measurements and any of the studied demographic or ocular parameters (R < 0.09, P < 0.001). Intra-and interobserver reproducibility of the measurements were good (intraclass correlation coefficient > 0.750, P < 0.001). CONCLUSIONS. The FD-OCT is an effective and reproducible examination technique to measure the length, thickness, and area of the TM in vivo.
引用
收藏
页码:1782 / 1788
页数:7
相关论文
共 50 条
  • [1] Anterior Chamber Angle and Trabecular Meshwork Measurements Made by Fourier-domain Optical Coherence Tomography in Healthy White Children
    Fernandez-Vigo, Jose I.
    De-Pablo-Gomez-de-Liano, Lucia
    Fernandez-Vigo, Cristina
    Arcos-Villegas, Gabriel
    Fernandez-Perez, Cristina
    Garcia-Feijoo, Julian
    Fernandez-Vigo, Jose A.
    JOURNAL OF GLAUCOMA, 2017, 26 (09) : 810 - 815
  • [2] In Vivo Comparison of Fourier-Domain Optical Coherence Tomography and Intravascular Ultrasonography
    Ramesh, Sathyadeepak
    Papayannis, Aristotelis
    Abdel-karim, Abdul-rahman
    Banerjee, Subhash
    Brilakis, Emmanouil
    JOURNAL OF INVASIVE CARDIOLOGY, 2012, 24 (03) : 111 - 115
  • [3] Assessment of trabecular meshwork width using swept source optical coherence tomography
    Tun, Tin A.
    Baskaran, Mani
    Zheng, Ce
    Sakata, Lisandro M.
    Perera, Shamira A.
    Chan, Anita S.
    Friedman, David S.
    Cheung, Carol Y.
    Aung, Tin
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (06) : 1587 - 1592
  • [4] Quantification of trabecular-iris contact and its prevalence by optical coherence tomography in a healthy Caucasian population
    Ignacio Fernandez-Vigo, Jose
    De-Pablo-Gomez-De-Liano, Lucia
    Fernandez-Vigo, Cristina
    Sanchez-Guillen, Ines
    Santos-Bueso, Enrique
    Maria Martinez-de-la-Casa, Jose
    Garcia-Feijoo, Julian
    Angel Fernandez-Vigo, Jose
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2017, 27 (04) : 417 - 422
  • [5] Corneal power measurement with Fourier-domain optical coherence tomography
    Tang, Maolong
    Chen, Alex
    Li, Yan
    Huang, David
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (12) : 2115 - 2122
  • [6] Diffusion-sensitive Fourier-domain optical coherence tomography
    Hagen-Eggert, M.
    Hillmann, D.
    Koch, P.
    Huettmann, G.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XV, 2011, 7889
  • [7] Full-field Fourier-domain optical coherence tomography
    Zvyagin, AV
    Blazkiewicz, P
    Vintrou, J
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE IX, 2005, 5690 : 44 - 53
  • [8] Anterior segment imaging: Fourier-domain optical coherence tomography versus time-domain optical coherence tomography
    Wylegala, Edward
    Teper, Slawornir
    Nowinska, Anna K.
    Milka, Michal
    Dobrowolski, Dariusz
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (08) : 1410 - 1414
  • [9] Fourier domain optical coherence tomography to assess the iridocorneal angle and correlation study in a large Caucasian population
    Ignacio Fernandez-Vigo, Jose
    Garcia-Feijoo, Julian
    Maria Martinez-de-la-Casa, Jose
    Garcia-Bella, Javier
    Arriola-Villalobos, Pedro
    Fernandez-Perez, Cristina
    Angel Fernandez-Vigo, Jose
    BMC OPHTHALMOLOGY, 2016, 16
  • [10] Analysis of Microkeratome Thin Flap Architecture Using Fourier-domain Optical Coherence Tomography
    Rocha, Karolinne Maia
    Randleman, J. Bradley
    Stulting, R. Doyle
    JOURNAL OF REFRACTIVE SURGERY, 2011, 27 (10) : 759 - 763