Morphometry of the Trabecular Meshwork In Vivo in a Healthy Population Using Fourier-Domain Optical Coherence Tomography

被引:36
作者
Fernandez-Vigo, Jose I. [1 ,2 ]
Garcia-Feijoo, Julian [1 ]
Martinez-de-la-Casa, Jose M. [1 ]
Garcia-Bella, Javier [1 ]
Fernandez-Vigo, Jose A. [2 ,3 ]
机构
[1] Univ Complutense Madrid, Inst Hlth Res, Clin San Carlos Univ Hosp, Dept Ophthalmol, Madrid, Spain
[2] Int Ctr Adv Ophthalmol, Madrid, Spain
[3] Univ Extremadura, Dept Ophthalmol, Badajoz, Spain
关键词
trabecular meshwork; optical coherence tomography; glaucoma anterior segment; ANTERIOR-CHAMBER ANGLE; ULTRASOUND BIOMICROSCOPY; IRIDOCORNEAL ANGLE; SEGMENT; REPRODUCIBILITY; IDENTIFICATION; PARAMETERS;
D O I
10.1167/iovs.14-16154
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. We measured the length, thickness, and area of the trabecular meshwork (TM) in vivo using Fourier domain optical coherence tomography (FD-OCT) in a Caucasian population of healthy subjects. METHODS. A cross-sectional study was done of 1006 healthy subjects. Left eyes were randomly selected. Age, sex, IOP, and spherical refractive error were noted. The depth and volume of the anterior chamber and the central corneal thickness were measured with Pentacam, while IOL Master was used to measure the axial length. The length, thickness, and area of the TM were measured through FD-OCT RTVue. A study was done to determine the correlation between TM size, and other demographic and ocular parameters. Finally, the reproducibility of the measurements was assessed for a subgroup of 50 eyes from 50 patients. RESULTS. We were able to measure the TM in 91.1% of the total eyes studied. The mean TM length was 496.99 +/- 92.77 mu m (range, 275-800), TM thickness was 174.16 +/- 28.14 mu m (range, 100-276), and TM area was 0.069 +/- 0.031 mm(2) (range, 0.023-0.133). No differences were found in terms of length and area for sex, although the TM was slightly thicker in men (P = 0.046). No correlation was observed between the TM measurements and any of the studied demographic or ocular parameters (R < 0.09, P < 0.001). Intra-and interobserver reproducibility of the measurements were good (intraclass correlation coefficient > 0.750, P < 0.001). CONCLUSIONS. The FD-OCT is an effective and reproducible examination technique to measure the length, thickness, and area of the TM in vivo.
引用
收藏
页码:1782 / 1788
页数:7
相关论文
共 38 条
[1]   STATISTICS IN MEDICAL JOURNALS - DEVELOPMENTS IN THE 1980S [J].
ALTMAN, DG .
STATISTICS IN MEDICINE, 1991, 10 (12) :1897-1913
[2]   Variation of Angle Parameters in Asians: An Anterior Segment Optical Coherence Tomography Study in a Population of Singapore Malays [J].
Amerasinghe, Nishani ;
Foster, Paul J. ;
Wong, Tien Yin ;
Htoon, Hla Myint ;
He, Mingguang ;
Shen, Sunny Y. ;
Aung, Han T. ;
Saw, Seang-Mei ;
Aung, Tin .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (06) :2626-2631
[3]   Detailed visualization of the anterior segment using Fourier-domain optical coherence tomography [J].
Asrani, Sanjay ;
Sarunic, Marinko ;
Santiago, Cecilia ;
Izatt, Joseph .
ARCHIVES OF OPHTHALMOLOGY, 2008, 126 (06) :765-771
[4]   A Hierarchical Cluster Analysis of Primary Angle Closure Classification Using Anterior Segment Optical Coherence Tomography Parameters [J].
Baek, Seunghee ;
Sung, Kyung Rim ;
Sun, Jae Hong ;
Lee, Jong Rak ;
Lee, Kyoung Sub ;
Kim, Chan Yun ;
Shon, Kilhwan .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (01) :848-853
[5]   Anterior Chamber Angle Evaluation with Fourier-Domain Optical Coherence Tomography [J].
Bald, Matthew ;
Li, Yan ;
Huang, David .
JOURNAL OF OPHTHALMOLOGY, 2012, 2012
[6]   Novel anterior-chamber angle measurements by high-definition optical coherence tomography using the Schwalbe line as the landmark [J].
Cheung, Carol Y. ;
Zheng, Ce ;
Ho, Ching-Lin ;
Tun, Tin A. ;
Kumar, Rajesh S. ;
El Sayyad, Fouad ;
Wong, Tien Y. ;
Aung, Tin .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2011, 95 (07) :955-959
[7]   Comparison of anterior segment optical coherence tomography and ultrasound biomicroscopy for assessment of the anterior segment [J].
Dada, Tanuj ;
Sihota, Ramanjit ;
Gadia, Ritu ;
Aggarwal, Anand ;
Mandal, Subrata ;
Gupta, Viney .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (05) :837-840
[8]   Age and sex variation in angle findings among normal Chinese subjects [J].
Friedman, David S. ;
Gazzard, Gus ;
Min, Chan Boon ;
Broman, Aimee T. ;
Quigley, Harry ;
Tielsch, James ;
Seah, Steve ;
Foster, Paul J. .
JOURNAL OF GLAUCOMA, 2008, 17 (01) :5-10
[9]   Comparison of Scheimpflug imaging and spectral domain anterior segment optical coherence tomography for detection of narrow anterior chamber angles [J].
Grewal, D. S. ;
Brar, G. S. ;
Jain, R. ;
Grewal, S. P. S. .
EYE, 2011, 25 (05) :603-611
[10]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181