Rapid full volume data acquisition by real-time 3-dimensional echocardiography for assessment of left ventricular indexes in children: A validation study compared with magnetic resonance imaging

被引:67
作者
Bu, LP
Munns, S
Zhang, HH
Disterhoft, M
Dixon, M
Stolpen, A
Sonka, M
Scholz, TD
Mahoney, LT
Ge, SP
机构
[1] Univ Iowa, Div Pediat Cardiol, Iowa City, IA 52242 USA
[2] Univ Iowa, Dept Radiol, Iowa City, IA 52242 USA
[3] Univ Iowa, Dept Elect & Comp Engn, Iowa City, IA 52242 USA
关键词
D O I
10.1016/j.echo.2004.11.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective. We sought to assess the feasibility, accuracy, and reproducibility of a rapid full volume acquisition strategy using real-time (RT) 3-dimensional (3D) echocardiography (3DE) for measurement of left ventricular (LV) volumes, mass, stroke volume (SV), and ejection fraction (EF) in children. Methods: A total of 19 healthy children (mean 10.6 +/- 2.8 years, 11 male and 9 female) were prospectively enrolled in this study. RT 3DE was performed using an ultrasound system to acquire full volume 3D dataset from the apical window with electrocardiographic triggering in 8 s/dataset. The images were processed offline using software. The LV endocardial and epicardial borders were traced manually to derive LV end-systolic volume, end-diastolic volume, mass, SV, and EF. Magnetic resonance imaging (MRI) studies were performed on a 1-5-T scanner using a breath hold 2-dimensional cine-FEESTA (fast imaging employing steady-state acquisition) sequence. Results. All RT 3DE and MRI data were acquired successfully for analysis. Measurements of LV end-systolic volume, end-diastolic volume, mass, SV, and EF by RT 3DE correlated well by Pearson regression (r = 0.86-0.97, P < .001) and agreed well by Bland-Altman analysis with MRI. The interobserver and intraobserver variability of RT 3DE measurements were less than 5%. Conclusions: This prospective study demonstrated that RT 3DE measurements of LV end-systolic volume, end-diastolic volume, mass, SV, and EF in children using rapid full volume acquisition strategy are feasible, accurate, and reproducible and are comparable with MRI measurements.
引用
收藏
页码:299 / 305
页数:7
相关论文
共 34 条
[1]   Superiority of 3-dimensional versus 2-dimensional echocardiography for left ventricular volume assessment in small piglet hearts [J].
Abdullah, M ;
Maeno, Y ;
Bigras, JL ;
McCrindle, BW ;
Smallhorn, JF ;
Boutin, C .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2000, 13 (10) :918-923
[2]   Feasibility, accuracy, and incremental value of intraoperative three-dimensional transesophageal echocardiography in valve surgery [J].
Abraham, TP ;
Warner, JG ;
Kon, ND ;
Lantz, PE ;
Fowle, KM ;
Brooker, RF ;
Ge, SP ;
Nomeir, AM ;
Kitzman, DW .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 (12) :1577-1582
[3]   Left ventricular ejection fraction in children measured by three-dimensional echocardiography using a new transthoracic integrated 3D-probe - A comparison with equilibrium radionuclide angiography [J].
Acar, P ;
Maunoury, C ;
Antonietti, T ;
Bonnet, D ;
Sidi, D ;
Kachaner, J .
EUROPEAN HEART JOURNAL, 1998, 19 (10) :1583-1588
[4]   Comparison of three-dimensional echocardiographic assessment of volume, mass, and function in children with functionally single left ventricles with two-dimensional echocardiography and magnetic resonance imaging [J].
Altmann, K ;
Shen, ZQ ;
Boxt, LM ;
King, DL ;
Gersony, WM ;
Allan, LD ;
Apfel, HD .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 (08) :1060-1065
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]  
Buck T, 1997, CIRCULATION, V96, P4286
[7]   SYSTEM FOR ULTRASONICALLY IMAGING HUMAN HEART IN 3 DIMENSIONS [J].
DEKKER, DL ;
PIZIALI, RL ;
DONG, E .
COMPUTERS AND BIOMEDICAL RESEARCH, 1974, 7 (06) :544-553
[8]   ECHOCARDIOGRAPHIC DETERMINATION OF LEFT-VENTRICULAR MASS IN MAN - ANATOMIC VALIDATION OF METHOD [J].
DEVEREUX, RB ;
REICHEK, N .
CIRCULATION, 1977, 55 (04) :613-618
[9]   A COMPOSITE 3-DIMENSIONAL ECHOCARDIOGRAPHIC TECHNIQUE FOR LEFT-VENTRICULAR VOLUME ESTIMATION IN CHILDREN - COMPARISON WITH ANGIOGRAPHY AND ESTABLISHED ECHOGRAPHIC METHODS [J].
FAZZALARI, NL ;
GOLDBLATT, E ;
ADAMS, APS .
JOURNAL OF CLINICAL ULTRASOUND, 1986, 14 (09) :663-674
[10]   Morphology and dynamic change of discrete subaortic stenosis can be imaged and quantified with three-dimensional transesophageal echocardiography [J].
Ge, SP ;
Warner, JG ;
Fowle, KM ;
Kon, ND ;
Brooker, RF ;
Nomeir, AM ;
Kitzman, DW .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1997, 10 (07) :713-716