The Amsterdam quintuplet nuclear microprobe

被引:8
作者
van den Putte, MJJ
van den Brand, JFJ
Jamieson, DN
Rout, B
Szymanski, R
机构
[1] Free Univ Amsterdam, Fac Sci, Div Phys & Astron, NL-1081 HV Amsterdam, Netherlands
[2] NIKHEF H, Natl Inst Nucl & High Energy Phys, NL-1009 DB Amsterdam, Netherlands
[3] Univ Melbourne, Sch Phys, Microanalyt Res Ctr, Parkville, Vic 3052, Australia
关键词
nuclear microprobe; ion beam facility; grid shadow measurement;
D O I
10.1016/S0168-583X(03)01006-1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new nuclear microprobe comprising of a quintuplet lens system is being constructed at the Ion Beam Facility of the "Vrije Universiteit" Amsterdam in collaboration with the Microanalytical Research Centre of the University of Melbourne. An overview of the Amsterdam set-up will be presented. Detailed characterisation of the individual lenses was performed with the grid shadow method using a 2000 mesh Cu grid mounted at a relative angle of 0.5degrees to the vertical lens line focus. The lenses were found to have very low parasitic aberrations equal or below the minimum detectable limit for the method, which was approximately 0.1% for the sextupole component and 0.2% for the octupole component. We present experimental and theoretical grid shadow patterns, showing results for all five lenses. Crown Copyright (C) 2003 Published by Elsevier B.V. All rights reserved.