Linear isotherm determination from linear gradient elution experiments

被引:10
作者
Pfister, David [1 ]
Steinebach, Fabian [1 ]
Morbidelli, Massimo [1 ]
机构
[1] ETH, Inst Chem & Bioengn, Dept Chem & Appl Biosci, CH-8093 Zurich, Switzerland
关键词
Chromatography model; Linear gradient elution; Exclusion effect; Parameter estimation; ION-EXCHANGE CHROMATOGRAPHY; SIZE-EXCLUSION CHROMATOGRAPHY; OPERATING-CONDITIONS; PEGYLATED PROTEINS; PREDICTION; PERFORMANCE; CURVES; MODEL;
D O I
10.1016/j.chroma.2014.11.067
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A procedure to estimate equilibrium adsorption parameters as a function of the modifier concentration in linear gradient elution chromatography is proposed and its reliability is investigated by comparison with experimental data. Over the past decades, analytical solutions of the so-called equilibrium model under linear gradient elution conditions were derived assuming that proteins and modifier molecules access the same fraction of the pore size distribution of the porous particles. The present approach developed in this work accounts for the size exclusion effect resulting in different exclusions for proteins and modifier. A new analytical solution was derived by applying perturbation theory for differential equations, and the 1st-order approximated solution is presented in this work. Eventually, a turnkey and reliable procedure to efficiently estimate isotherm parameters as a function of modifier concentration from linear gradient elution experiments is proposed. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:33 / 41
页数:9
相关论文
共 22 条
[1]  
Bates D.M., 2008, Nonlinear regression models used in the evaluation of rumen digestion data
[2]   STERIC MASS-ACTION ION-EXCHANGE - DISPLACEMENT PROFILES AND INDUCED SALT GRADIENTS [J].
BROOKS, CA ;
CRAMER, SM .
AICHE JOURNAL, 1992, 38 (12) :1969-1978
[3]  
Carta G, 2010, PROTEIN CHROMATOGRAP, P277
[4]  
Cutler P., 2004, PROTEIN PURIFICATION, V2
[5]   Distributed pore model for bio-molecule chromatography [J].
de Neuville, Bertrand Coquebert ;
Tarafder, Abhijit ;
Morbidelli, Massimo .
JOURNAL OF CHROMATOGRAPHY A, 2013, 1298 :26-34
[6]   Pore size distributions of cation-exchange adsorbents determined by inverse size-exclusion chromatography [J].
DePhillips, P ;
Lenhoff, AM .
JOURNAL OF CHROMATOGRAPHY A, 2000, 883 (1-2) :39-54
[7]  
Desai M.A., 2000, Downstream Processing of Proteins: Methods and Protocols
[8]   Beyond traditional statistical methods [J].
Duckworth, WA ;
Stephenson, WR .
AMERICAN STATISTICIAN, 2002, 56 (03) :230-233
[9]   Prediction of the viscosity radius and the size exclusion chromatography behavior of PEGylated proteins [J].
Fee, CJ ;
Van Alstine, JM .
BIOCONJUGATE CHEMISTRY, 2004, 15 (06) :1304-1313
[10]   ION EXCHANGE AS A SEPARATIONS METHOD .9. GRADIENT ELUTION THEORY [J].
FREILING, EC .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1955, 77 (08) :2067-2071