The Design of a Digital Magnetic Induction Tomography (MIT) System for Metallic Object Imaging Based on Half Cycle Demodulation

被引:58
作者
Yin, Wuliang [1 ]
Chen, Guang [1 ]
Chen, Lijing [1 ]
Wang, Ben [1 ]
机构
[1] Tianjin Univ, Sch Elect Engn & Automat, Tianjin 300072, Peoples R China
基金
美国国家科学基金会;
关键词
Digital system; imaging; metallic objects; magnetic induction tomography (MIT);
D O I
10.1109/JSEN.2011.2128866
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents several important aspects of a highly integrated, Field Programmable Gate Array (FPGA)-based digital Magnetic Induction Tomography (MIT) system for metallic object imaging applications. Excitation signal generation, receiving signal demodulation, and channel multiplexing control are all implemented inside a Xilinx FPGA (Spartan III). A novel digital demodulation method using only half of the signal cycle is proposed and implemented, which improves the operation speed of the system by two folds. A geometrical scaling relationship has been discovered for MIT sensors, and a particular design has been implemented. Two imaging reconstruction algorithms (Tikhonov Regularization and Total Variation method) are applied to experimental data. The performance of the system has been verified.
引用
收藏
页码:2233 / 2240
页数:8
相关论文
共 21 条
[1]   Magnetic induction tomography [J].
Griffiths, H .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2001, 12 (08) :1126-1131
[2]  
Korzhenevsky A. V., 2001, Bulletin of the Russian Academy of Sciences. Physics, V65, P1945
[3]   Electromagnetic techniques for imaging the cross-section distribution of molten steel flow in the continuous casting nozzle [J].
Ma, XD ;
Peyton, AJ ;
Binns, R ;
Higson, SR .
IEEE SENSORS JOURNAL, 2005, 5 (02) :224-232
[4]   Solution of the inverse problem of magnetic induction tomography (MIT) [J].
Merwa, R ;
Hollaus, K ;
Brunner, P ;
Scharfetter, H .
PHYSIOLOGICAL MEASUREMENT, 2005, 26 (02) :S241-S250
[5]   Detection of brain oedema using magnetic induction tomography: a feasibility study of the likely sensitivity and detectability [J].
Merwa, R ;
Hollaus, K ;
Oszkar, B ;
Scharfetter, H .
PHYSIOLOGICAL MEASUREMENT, 2004, 25 (01) :347-354
[6]  
Patz R., 2009, P 10 INT C BIOM EIT
[7]  
Patz R., J PHYS C SER, V224
[8]  
Peyton A. J., 2003, Biometrie Humaine et Anthropologie, V21, P69
[9]   A model for the forward problem in magnetic induction tomography using boundary integral equations [J].
Pham, M. H. ;
Peyton, A. J. .
IEEE TRANSACTIONS ON MAGNETICS, 2008, 44 (10) :2262-2267
[10]   Nonlinear image reconstruction for electrical capacitance tomography using experimental data [J].
Soleimani, M ;
Lionheart, WRB .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2005, 16 (10) :1987-1996