Ultra-high performance supercritical fluid chromatography in impurity control II: Method validation

被引:6
|
作者
Plachka, Katerina [1 ]
Khalikova, Maria [1 ]
Babicova, Barbora [1 ]
Nemcova, Zdenka [1 ]
Roubickova, Lucie [1 ]
Svec, Frantisek [1 ]
Novakova, Lucie [1 ]
机构
[1] Charles Univ Prague, Fac Pharm Hradec Kralove, Dept Analyt Chem, Heyrovskeho 1203, Hradec Kralove 50005, Czech Republic
关键词
Ultra-high performance supercritical fluid chromatography; Impurity control; Pharmaceutical compounds; Method validation; Quality control; PHASE LIQUID-CHROMATOGRAPHY; QUANTITATIVE-DETERMINATION; STATIONARY PHASES; SFC; QUANTIFICATION;
D O I
10.1016/j.aca.2020.04.038
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In our previous study we proposed a screening approach using ultra-high performance supercritical fluid chromatography for the determination of 10 pharmaceutical quality control mixtures. Most of resulting methods offered baseline separation of all analytes. However, some of these methods had to be further optimized to ensure their successful validation and applicability to impurity control in drug substance and drug products. Several challenges occurred during the optimization including: (i) the necessity of the resolution of active pharmaceutical ingredient and following impurity equaling at least 3, which was especially difficult to achieve for mixtures of structurally close compounds, (ii) unrepeatable elution of compounds eluting close to the dead volume or at the end of the gradient elution, and (iii) shifts in retention times due to the column aging and effects of additive. The most frequent optimization adjustments involved changes in gradient program. Other adjustments such as the substitution of Viridis UPC2 HSS C18 SB column with a slightly different Acquity UPLC HSS C18 SB column, the addition of acetonitrile in the modifier, and the column coupling also led to beneficial changes in selectivity. Subsequently, validation of all 10 methods was carried out to prove the applicability of ultra-high performance supercritical fluid chromatography methods for the impurity control in pharmaceuticals. Parameters recommended by ICH guidelines Q2 and Q3 including specificity, linearity, range, lower and upper limit of quantification, limit of detection, accuracy, and precision were examined. In addition, intermediate precision and the accuracy profiles were determined for selected methods. Overall, only two impurities did not meet the validation criteria due to low resolution and low sensitivity, respectively. Only identification threshold and not reporting threshold was met for this impurity. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页码:48 / 59
页数:12
相关论文
共 50 条
  • [41] A comparison of chiral separations by supercritical fluid chromatography and high-performance liquid chromatography
    Ali, Imran
    Raja, Rupak
    Alam, Syed Dilshad
    Shirsath, Vikas
    K. Jain, Arvind
    Locatelli, Marcello
    David, Victor
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2021, 44 (11-12) : 550 - 563
  • [42] Possibilities of retention modeling and computer assisted method development in supercritical fluid chromatography
    Tyteca, Eva
    Desfontaine, Vincent
    Desmet, Gert
    Guillarme, Davy
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1381 : 219 - 228
  • [43] Development and validation of an ultra-high performance liquid chromatography/triple quadrupole mass spectrometry method for analyzing microbial-derived grape polyphenol metabolites
    Zhao, Danyue
    Yuan, Bo
    Carry, Eileen
    Pasinetti, Giulio M.
    Ho, Lap
    Faith, Jeremiah
    Mogno, Ilaria
    Simon, Jim
    Wu, Qingli
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1099 : 34 - 45
  • [44] Development and validation of an ultra-performance convergence chromatography method for the quality control of Angelica gigas Nakai
    Kim, Hyo Seon
    Chun, Jin Mi
    Kwon, Bo-In
    Lee, A-Reum
    Kim, Ho Kyoung
    Lee, A. Yeong
    JOURNAL OF SEPARATION SCIENCE, 2016, 39 (20) : 4035 - 4041
  • [45] An analytical strategy for accurate, rapid and sensitive quantitative analysis of isoflavones in traditional Chinese medicines using ultra-high performance supercritical fluid chromatography: Take Radix Puerariae as an example
    Wu, Wenjie
    Zhang, Yuan
    Zhang, Feng
    Liu, Jian
    Ren, Zhiqin
    Xu, Yongwei
    Liu, Tong
    Zhou, Weie
    Li, Hongna
    Zhang, Chuanbin
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1606
  • [46] Performance of the same column in supercritical fluid chromatography and in liquid chromatography
    Lambert, Nandor
    Felinger, Attila
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1409 : 234 - 240
  • [47] Development of an untargeted DNA adductomics method by ultra-high performance liquid chromatography coupled to high-resolution mass spectrometry
    La Barbera, Giorgia
    Shuler, Marshal Spenser
    Beck, Soren Hammershoj
    Ibsen, Per Holger
    Lindberg, Lars Joachim
    Karstensen, John Gasdal
    Dragsted, Lars Ove
    TALANTA, 2025, 282
  • [48] Advances in High Throughput Supercritical Fluid Chromatography
    Farrell, William P.
    Aurigemma, Christine M.
    Masters-Moore, David F.
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2009, 32 (11-12) : 1689 - 1710
  • [49] Supercritical fluid in analytical chemistry.: II.: Supercritical fluid chromatography:: Instrumentation.
    Carrilho, E
    Tavares, MCH
    Lanças, FM
    QUIMICA NOVA, 2003, 26 (05): : 687 - 693
  • [50] Method validation for the detection of formaldehyde in fish using ultra performance liquid chromatography
    Dhruve, Domendra
    Shalini, Rajendran
    Shakila, Robinson Jeya
    Arisekar, Ulaganthan
    Jeyasekaran, Geevaretnam
    Hemamalini, Asha
    Ratrey, Vedprakash
    INDIAN JOURNAL OF FISHERIES, 2024, 71 (03): : 108 - 114