Amplification of the phase contrast signal at very high x-ray energies

被引:35
作者
Olivo, Alessandro [1 ]
Diemoz, Paul C. [1 ]
Bravin, Alberto [2 ]
机构
[1] UCL, Dept Med Phys & Bioengn, London WC1E 6BT, England
[2] European Synchrotron Radiat Facil, F-38043 Grenoble, France
基金
英国工程与自然科学研究理事会;
关键词
GRATING INTERFEROMETER; SYNCHROTRON-RADIATION; COMPUTED-TOMOGRAPHY;
D O I
10.1364/OL.37.000915
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
X-ray phase contrast imaging is increasingly being used in several fields, both at synchrotron facilities and with laboratory sources, due to its increased sensitivity compared to conventional x-ray methods. One important problem is the development of methods to make it suitable for use at very high x-ray energies, needed in many applications. We show how the edge illumination concept, which stands at the basis of the coded-aperture method, allows achieving hyperintense phase signals at energies close to 100 keV, by showing images of both weak phase objects and highly absorbing fossils with a high iron content. (C) 2012 Optical Society of America
引用
收藏
页码:915 / 917
页数:3
相关论文
共 20 条
[1]   Low-dose phase contrast x-ray medical imaging [J].
Arfelli, F ;
Assante, M ;
Bonvicini, V ;
Bravin, A ;
Cantatore, G ;
Castelli, E ;
Dalla Palma, L ;
Di Michiel, M ;
Longo, R ;
Olivo, A ;
Pani, S ;
Pontoni, D ;
Poropat, P ;
Prest, M ;
Rashevsky, A ;
Tromba, G ;
Vacchi, A ;
Vallazza, E ;
Zanconati, F .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (10) :2845-2852
[2]  
Born M., 1999, Principles of optics, Vseventh
[3]   The Endocast of MH1, Australopithecus sediba [J].
Carlson, Kristian J. ;
Stout, Dietrich ;
Jashashvili, Tea ;
de Ruiter, Darryl J. ;
Tafforeau, Paul ;
Carlson, Keely ;
Berger, Lee R. .
SCIENCE, 2011, 333 (6048) :1402-1407
[4]   Evaluation of imaging performance of a taper optics CCD 'FReLoN' camera designed for medical imaging [J].
Coan, P ;
Peterzol, A ;
Fiedler, S ;
Ponchut, C ;
Labiche, JC ;
Bravin, A .
JOURNAL OF SYNCHROTRON RADIATION, 2006, 13 :260-270
[5]   PHASE-CONTRAST IMAGING OF WEAKLY ABSORBING MATERIALS USING HARD X-RAYS [J].
DAVIS, TJ ;
GAO, D ;
GUREYEV, TE ;
STEVENSON, AW ;
WILKINS, SW .
NATURE, 1995, 373 (6515) :595-598
[6]   A simplified approach for computed tomography with an X-ray grating interferometer [J].
Diemoz, P. C. ;
Coan, P. ;
Zanette, I. ;
Bravin, A. ;
Lang, S. ;
Glaser, C. ;
Weitkamp, T. .
OPTICS EXPRESS, 2011, 19 (03) :1691-1698
[7]   Phase-contrast imaging and tomography at 60 keV using a conventional x-ray tube source [J].
Donath, Tilman ;
Pfeiffer, Franz ;
Bunk, Oliver ;
Groot, Waldemar ;
Bednarzik, Martin ;
Gruenzweig, Christian ;
Hempel, Eckhard ;
Popescu, Stefan ;
Hoheisel, Martin ;
David, Christian .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (05)
[8]   Coded apertures allow high-energy x-ray phase contrast imaging with laboratory sources [J].
Ignatyev, K. ;
Munro, P. R. T. ;
Chana, D. ;
Speller, R. D. ;
Olivo, A. .
JOURNAL OF APPLIED PHYSICS, 2011, 110 (01)
[9]   X-RAY PLANE-WAVE TOPOGRAPHY OBSERVATION OF THE PHASE-CONTRAST FROM A NONCRYSTALLINE OBJECT [J].
INGAL, VN ;
BELIAEVSKAYA, EA .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1995, 28 (11) :2314-2317
[10]   Dual energy phase contrast x-ray imaging with Talbot-Lau interferometer [J].
Kottler, Christian ;
Revol, Vincent ;
Kaufmann, Rolf ;
Urban, Claus .
JOURNAL OF APPLIED PHYSICS, 2010, 108 (11)