Stellarator WEGA as a test-bed for the WENDELSTEIN 7-X control system concepts

被引:20
作者
Schacht, Joerg [1 ]
Assmus, Dieter [1 ]
Bluhm, Torsten [1 ]
Dinklage, Andreas [1 ]
Heinrich, Stefan [1 ]
Hennig, Christine [1 ]
Herbst, Uwe [1 ]
Koenig, Ralf [1 ]
Laqua, Heike [1 ]
Lewerentz, Marc [1 ]
Mueller, Ina [1 ]
Otte, Matthias [1 ]
Pingel, Steffen [1 ]
Sachtleben, Juergen [1 ]
Spring, Anett [1 ]
Werner, Andreas [1 ]
Woelk, Andreas [1 ]
机构
[1] Max Planck Inst Plasma Phys, Tedinst Greiswald, D-17491 Greifswald, Germany
关键词
control system; fusion experiment; WENDELSTEIN; 7-X; real-time control; segment processing; slow control; safety system;
D O I
10.1016/j.fusengdes.2007.09.016
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The concepts for the control of the fusion experiment WENDELSTEIN 7-X (W7-X) consider all requirements regarding safety, steady-state operation, flexibility, availability, performance and scalability. The early demonstration of the steady-state control concepts with all interacting parties is necessary to minimize development costs since integrated tests of components are scheduled for a later stage of the W7-X project planning. Therefore the implementation of an integrated test-bed for the control concepts of W7-X is very important to minimize project risks. Main objectives of the test-bed project are an integrated test of control, data acquisition, diagnostics operation and data processing in a W7-X-like environment (steady-state segmented operation, real-time control, interplay of the central slow control system with components control systems, on-line data analysis tools), a demonstration of the W7-X safety concept and the education of engineers and session leaders for a W7-X-like machine operation. The contribution describes the use of the small in-house stellarator experiment WEGA as test-bed for the W7-X control concepts. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:228 / 235
页数:8
相关论文
共 7 条
[1]  
Grieger G, 1998, J PLASMA FUSION RES, V1
[2]   Editor for system configuration and experiment program specification [J].
Kühner, G ;
Heimann, P ;
Heinzel, S ;
Hennig, C ;
Kühntopf, H ;
Kroiss, H ;
Maier, J ;
Reetz, J ;
Zilker, M .
FUSION ENGINEERING AND DESIGN, 2004, 71 (1-4) :225-230
[3]   Control system of WENDELSTEIN 7-X experiment [J].
Laqua, H ;
Niedermeyer, H ;
Schacht, J .
FUSION ENGINEERING AND DESIGN, 2003, 66-68 :669-673
[4]  
LAQUA H, 2002, FUSION ENG DES, V60, P373
[5]  
SCHACHT J, 2007, P 15 IEEE NPSS REAL
[6]  
SCHACHT J, 2005, P 14 IEEE NPSS REAL
[7]   User interaction concept for plasma discharge control on WENDELSTEIN 7-X [J].
Spring, Anett ;
Laqua, Heike ;
Niedermeyer, Helmut .
FUSION ENGINEERING AND DESIGN, 2006, 81 (15-17) :1957-1961