Dose and dose rate dependence of time-resolved OSL from Korean paleosol quartz

被引:7
作者
Kim, M. J. [1 ]
Choi, J. H. [2 ]
Hong, D. G. [1 ]
机构
[1] Kangwon Natl Univ, Dept Phys, Chunchon 200701, Gangwon Do, South Korea
[2] Korea Basic Sci Inst, Geochronol Team, Taejon 305333, South Korea
关键词
TR-OSL; Dose dependence; Dose rate dependence; X-ray irradiation; OPTICALLY STIMULATED LUMINESCENCE; POINT-DEFECTS;
D O I
10.1016/j.radmeas.2011.03.022
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Using a newly developed small X-ray irradiator equipped with a mini X-ray generator (Varian VF-50J) and TR-OSL measurement system attached to an MCS (ORTEC MCS-PCI), the influence of dose and dose rate of X-ray radiation on TR-OSL was investigated in paleosol quartz from the Chungdang-dong paleolithic site, Korea. All lifetimes were calculated by a curve-fitting method using a single stretched-exponential function with beta = 0.86. Physical characteristics, natural lifetime, thermal quenching activation energy Delta E, and thermal assistance activation energy E-a were firstly determined. From the results of the investigation of dependence on dose and dose rate of X-ray radiation using fully bleached samples, the lifetime decreased significantly to about 20 its: when the X-ray dose was increased to 300 Gy at a dose rate of 0.5 Gy/s. Also, despite different radiation dose rates, at a dose of 50 Gy both lifetime and related intensity were independent of dose rate change. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1518 / 1521
页数:4
相关论文
共 50 条
  • [41] PTW-diamond detector: Dose rate and particle type dependence
    Fidanzio, A
    Azario, L
    Miceli, R
    Russo, A
    Piermattei, A
    MEDICAL PHYSICS, 2000, 27 (11) : 2589 - 2593
  • [42] DOSE DEPENDENCE OF THE THERMOLUMINESCENCE (TL) PEAK AT 200 K IN AL-NA CONTAINING QUARTZ CRYSTALS
    HALPERIN, A
    SUCOV, EW
    JOURNAL OF PHYSICS AND CHEMISTRY OF SOLIDS, 1993, 54 (04) : 431 - 437
  • [43] Investigations into the reliability of SAR-OSL equivalent doses obtained for quartz samples displaying dose response curves with more than one component
    Timar-Gabor, A.
    Vasiliniuc, S.
    Vandenberghe, D. A. G.
    Cosma, C.
    Wintle, A. G.
    RADIATION MEASUREMENTS, 2012, 47 (09) : 740 - 745
  • [44] Household salt for retrospective dose assessments using OSL: signal integrity and its dependence on containment, sample collection, and signal readout
    Christiansson, Maria
    Bernhardsson, Christian
    Geber-Bergstrand, Therese
    Mattsson, Soren
    Raaf, Christopher L.
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2014, 53 (03) : 559 - 569
  • [45] Dose-rate dependence and IMRT QA suitability of EBT3 radiochromic films for pulse reduced dose-rate radiotherapy (PRDR) dosimetry
    Khan, Ahtesham Ullah
    Radtke, Jeff
    Hammer, Clifford
    Malyshev, Julia
    Morris, Brett
    Glide-Hurst, Carri
    Dewerd, Larry
    Culberson, Wesley
    Bayliss, Adam
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (01):
  • [46] OSL and photo-transferred TL of quartz single crystals sensitized by high-dose of gamma-radiation and moderate heat-treatments
    Ferreira de Souza, Leonardo B.
    Guzzo, Pedro L.
    Khoury, Helen J.
    APPLIED RADIATION AND ISOTOPES, 2014, 94 : 93 - 100
  • [47] Variation of luminescence sensitivity, characteristic dose and trap parameters of quartz from rocks and sediments
    Mineli, T. D.
    Sawakuchi, A. O.
    Guralnik, B.
    Lambert, R.
    Jain, M.
    Pupim, F. N.
    del Rio, I.
    Guedes, C. C. F.
    Nogueira, L.
    RADIATION MEASUREMENTS, 2021, 144 (144)
  • [48] Underestimation of SAR equivalent doses for quartz from West Africa: A dose recovery study
    Tribolo, C.
    Stokes, S.
    RADIATION MEASUREMENTS, 2006, 41 (7-8) : 930 - 935
  • [49] Modelling the dependence of equivalent dose determined from a dose recovery test on preheating temperature: The intervention of shallow electron traps
    Peng, Jun
    Wang, Xulong
    Adamiec, Grzegorz
    Pagonis, Vasilis
    Choi, Jeong-Heon
    RADIATION MEASUREMENTS, 2021, 142
  • [50] Dose-rate dependence of negative copper ion implantation into silica glasses and effects on colloid formation
    Kishimoto, N
    Gritsyna, VT
    Takeda, Y
    Lee, CG
    Saito, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1998, 141 (1-4) : 299 - 303