Partial volume effect of SPECT images in PRRT with 177Lu labelled somatostatin analogues: A practical solution

被引:12
作者
Finocchiaro, Domenico [1 ,2 ]
Berenato, Salvatore [3 ]
Grassi, Elisa [1 ]
Bertolini, Valentina [1 ]
Castellani, Gastone [2 ]
Lanconelli, Nico [2 ]
Versari, Annibale [4 ]
Spezi, Emiliano [3 ,5 ]
Iori, Mauro [1 ]
Fioroni, Federica [1 ]
机构
[1] Azienda Unita Sanitaria Locale IRCCS Reggio Emili, Med Phys Unit, Reggio Emilia, Italy
[2] Univ Bologna, Dept Phys, Bologna, Italy
[3] Cardiff Univ, Sch Engn, Cardiff, S Glam, Wales
[4] Azienda Unita Sanitaria Locale IRCCS Reggio Emili, Nucl Med Unit, Reggio Emilia, Italy
[5] Velindre Canc Ctr, Dept Med Phys, Cardiff, S Glam, Wales
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2019年 / 57卷
关键词
Partial volume effect; Partial volume correction; SPECT; Quantitative imaging; Recovery coefficient; DOSIMETRY; PET; QUANTIFICATION; TOMOGRAPHY; GUIDELINES; THERAPY;
D O I
10.1016/j.ejmp.2018.12.029
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: At present activity quantification is one of the most critical step in dosimetry calculation, and Partial Volume Effect (PVE) one of the most important source of error. In recent years models based upon phantoms that incorporate hot spheres have been used to establish recovery models. In this context the goal of this study was to point out the most critical issues related to PVE and to establish a model closer to a biological imaging environment. Methods: Two different phantoms, filled with a Lu-177 solution, were used to obtain the PVE Recovery Coefficients (RCs): a phantom with spherical inserts and a phantom with organ-shaped inserts. Two additional phantoms with inserts of various geometrical shapes and an anthropomorphic phantom were acquired to compare the real activities to predicted values after PVE correction. Results: The RCs versus volume of the inserts produced two different curves, one for the spheres and one for the organs. After PVE correction, accuracy on activity quantification averaged over all inserts of three test phantoms passed from - 26% to 1.3% (from 26% to 10% for absolute values). Conclusion: RCs is a simple method for PVE correction easily applicable in clinical routine. The use of two different models for organs and lesions has permitted to closely mimic the situation in a living subject. A marked improvement in the quantification of activity was observed when PVE correction was adopted, even if further investigations should be performed for more accurate models of PVE corrections.
引用
收藏
页码:153 / 159
页数:7
相关论文
共 30 条
[1]   Asphericity of pretherapeutic tumour FDG uptake provides independent prognostic value in head-and-neck cancer [J].
Apostolova, Ivayla ;
Steffen, Ingo G. ;
Wedel, Florian ;
Lougovski, Alexandr ;
Marnitz, Simone ;
Derlin, Thorsten ;
Amthauer, Holger ;
Buchert, Ralph ;
Hofheinz, Frank ;
Brenner, Winfried .
EUROPEAN RADIOLOGY, 2014, 24 (09) :2077-2087
[2]   Evaluation of advanced automatic PET segmentation methods using nonspherical thin-wall inserts [J].
Berthon, B. ;
Marshall, C. ;
Evans, M. ;
Spezi, E. .
MEDICAL PHYSICS, 2014, 41 (02)
[3]   Quantitative 177Lu SPECT imaging using advanced correction algorithms in non-reference geometry [J].
D'Arienzo, M. ;
Cozzella, M. L. ;
Fazio, A. ;
De Felice, P. ;
Iaccarino, G. ;
D'Andrea, M. ;
Ungania, S. ;
Cazzato, M. ;
Schmidt, K. ;
Kimiaei, S. ;
Strigari, L. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (12) :1745-1752
[4]   CERR: A computational environment for radiotherapy research [J].
Deasy, JO ;
Blanco, AI ;
Clark, VH .
MEDICAL PHYSICS, 2003, 30 (05) :979-985
[5]   Monte Carlo evaluation of object shape effects in iodine-1 31 SPET tumor activity quantification [J].
Dewaraja, YK ;
Ljungberg, M ;
Koral, KF .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (07) :900-906
[6]   MIRD Pamphlet No. 24: Guidelines for Quantitative 131I SPECT in Dosimetry Applications [J].
Dewaraja, Yuni K. ;
Ljungberg, Michael ;
Green, Alan J. ;
Zanzonico, Pat B. ;
Frey, Eric C. .
JOURNAL OF NUCLEAR MEDICINE, 2013, 54 (12) :2182-2188
[7]   A review of partial volume correction techniques for emission tomography and their applications in neurology, cardiology and oncology [J].
Erlandsson, Kjell ;
Buvat, Irene ;
Pretorius, P. Hendrik ;
Thomas, Benjamin A. ;
Hutton, Brian F. .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (21) :R119-R159
[8]   Quantitative comparison between the commercial software STRATOS® by Philips and a homemade software for voxel-dosimetry in radiopeptide therapy [J].
Grassi, E. ;
Fioroni, F. ;
Ferri, V. ;
Mezzenga, E. ;
Sarti, M. A. ;
Paulus, T. ;
Lanconelli, N. ;
Filice, A. ;
Versari, A. ;
Iori, M. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (01) :72-79
[9]  
Grassi E., 2017, Radiol Diagn Imaging, V1, P1, DOI [10.15761/RDI.1000101, DOI 10.15761/RDI.1000101]
[10]   Effect of image registration on 3D absorbed dose calculations in 177Lu-DOTATOC peptide receptor radionuclide therapy [J].
Grassi, Elisa ;
Fioroni, Federica ;
Berenato, Salvatore ;
Patterson, Nick ;
Ferri, Valentina ;
Braglia, Luca ;
Filice, Angelina ;
Versari, Annibale ;
Iori, Mauro ;
Spezi, Emiliano .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 45 :177-185