Measuring Intraocular Pressure After Intrastromal Corneal Ring Segment Implantation With Rebound Tonometry and Goldmann Applanation Tonometry

被引:10
作者
Arribas-Pardo, Paula [1 ]
Mendez-Hernandez, Carmen [1 ]
Cuina-Sardina, Ricardo [1 ]
Fernandez-Perez, Cristina
Diaz-Valle, David [1 ]
Garcia-Feijoo, Julian [1 ]
机构
[1] Univ Complutense Madrid, Dept Ophthalmol, Hosp Clinico San Carlos, Inst Hlth Care Res,Hosp Clin San Carlos IdISSC, Madrid, Spain
关键词
Both RBTs could be an alternative to GAT in patients with corneal ectasia and ICRS; however; Icare Pro shows greater accuracy; DYNAMIC CONTOUR TONOMETRY; OCULAR RESPONSE ANALYZER; PENETRATING KERATOPLASTIES; GLAUCOMA PATIENTS; ICARE TONOMETER; IOP MEASUREMENT; KERATOCONUS; THICKNESS; BIOMECHANICS; LAMELLAR;
D O I
10.1097/ICO.0000000000000374
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The aim of this study was to compare intraocular pressure (IOP) measurements in patients with ectatic corneas after intrastromal corneal ring segment (ICRS) implantation using the Rebound tonometers (RBTs) Icare and Icare Pro, compared with Goldmann applanation tonometry (GAT) and to assess the influence of central corneal thickness (CCT), corneal curvature (CC), and corneal astigmatism (CA) on IOP. Methods: This prospective cross-sectional study consecutively included 60 eyes of 60 patients with corneal ectasia having ICRS for at least 6 months from January 2011 to December 2013. All subjects underwent GAT, Icare, and Icare Pro IOP measurements in a random order, and CCT, CC, and CA evaluation using a Pentacam. The Bland-Altman method and multivariate regression analysis logistic method were used to assess intertonometer agreement and the influence of corneal variables on IOP measurements. Results: Icare significantly underestimated IOP compared with GAT [GAT - Icare 1.2 +/- 3.0 mm Hg, P = 0.002 (95% confidence interval, 0.5-2.0)], whereas Icare Pro showed no statistical differences compared with GAT [GAT - Icare Pro 0.1 +/- 3.1 mm Hg, P = 0.853 (95% confidence interval, 20.7 to 0.9)]. Both RBTs presented good concordance with GAT (intraclass coefficient correlation > 0.6). All tonometer measurements were influenced by CCT values and age (P < 0.05); the number of ICRS implanted did not influenced IOP measurement with any of the 3 tonometers. Conclusions: Both RBTs could be an alternative to GAT in patients with corneal ectasia and ICRS; however, Icare Pro shows greater accuracy.
引用
收藏
页码:516 / 520
页数:5
相关论文
共 34 条
[1]   Comparison of ICare tonometer with Goldmann applanation tonometer in glaucoma patients [J].
Brusini, P ;
Salvetat, ML ;
Zeppieri, M ;
Tosoni, C ;
Parisi, L .
JOURNAL OF GLAUCOMA, 2006, 15 (03) :213-217
[2]   Comparison of dynamic contour tonometry and Goldmann applanation tonometry in deep lamellar and penetrating keratoplasties [J].
Ceruti, Piero ;
Morbio, Roberta ;
Marraffa, Michele ;
Marchini, Giorgio .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 145 (02) :215-221
[3]   Rebound tonometry: new opportunities and limitations of non-invasive determination of intraocular pressure [J].
Cervino, A. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2006, 90 (12) :1444-1446
[4]   The influence of cornea properties on rebound tonometry [J].
Chui, Wan-sang ;
Lam, Andrew ;
Chen, Davie ;
Chiu, Roger .
OPHTHALMOLOGY, 2008, 115 (01) :80-84
[5]   Biomechanical and morphological corneal response to placement of intrastromal corneal ring segments for keratoconus [J].
Dauwe, Caroline ;
Touboul, David ;
Roberts, Cynthia J. ;
Mahmoud, Ashraf M. ;
Kerautret, Julien ;
Fournier, Pierre ;
Malecaze, Francois ;
Colin, Joseph .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (10) :1761-1767
[6]   DYNAMIC TONOMETRY [J].
DEKKING, HM ;
COSTER, HD .
OPHTHALMOLOGICA, 1967, 154 (01) :59-&
[7]   Tonometry in Corneal Edema after Cataract Surgery: Rebound versus Goldmann Applanation Tonometry [J].
Fuest, Matthias ;
Mamas, Nikolaos ;
Walter, Peter ;
Plange, Niklas .
CURRENT EYE RESEARCH, 2014, 39 (09) :902-907
[8]   Intrastromal corneal ring segments for management of keratoconus [J].
Ganesh, Sri ;
Shetty, Rohit ;
D'Souza, Sharon ;
Ramachandran, Sarika ;
Kurian, Mathew .
INDIAN JOURNAL OF OPHTHALMOLOGY, 2013, 61 (08) :451-455
[9]   Intraocular pressure and photorefractive keratectomy - A comparison of three different tonometers [J].
Garzozi, HJ ;
Chung, HS ;
Lang, YR ;
Kagemann, L ;
Harris, A .
CORNEA, 2001, 20 (01) :33-36
[10]   Influence of intrastromal corneal ring segment implantation on corneal biomechanical parameters in keratoconic eyes [J].
Gorgun, Ebru ;
Kucumen, Raciha Beril ;
Yenerel, Nursal Melda .
JAPANESE JOURNAL OF OPHTHALMOLOGY, 2011, 55 (05) :467-471