Contrast Enhanced Three Dimensional Ultrasound for Intraluminal Thrombus Assessment in Abdominal Aortic Aneurysms

被引:14
作者
Ghulam, Qasam M. [1 ,2 ]
Bredahl, Kim [1 ]
Sandholt, Benjamin [1 ,2 ]
Taudorf, Mikkel [3 ]
Lonn, Lars [2 ,3 ]
Rouet, Laurence [4 ]
Sillesen, Henrik [1 ,2 ]
Eiberg, Jonas P. [1 ,2 ,5 ]
机构
[1] Rigshosp, Dept Vasc Surg, 3111,Blegdamsvej 9, DK-2100 Copenhagen, Denmark
[2] Univ Copenhagen, Fac Hlth & Med Sci, Copenhagen, Denmark
[3] Rigshosp, Dept Radiol, Copenhagen, Denmark
[4] Philips Res, Medisys, Suresnes, France
[5] CAMES, Copenhagen, Denmark
关键词
Abdominal aortic aneurysm; Three dimensional contrast enhanced ultrasound; Intraluminal thrombus volume; Intraluminal thrombus thickness; COMPUTED-TOMOGRAPHY; DIAMETER; GROWTH; VOLUME; MORPHOLOGY; SAC;
D O I
10.1016/j.ejvs.2018.07.029
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives: The impact of intraluminal thrombus (ILT) on abdominal aortic aneurysm (AAA) progression can be investigated non-invasively by three dimensional contrast enhanced ultrasound (3D-CEUS). The aim was to validate 3D-CEUS ILT volume and thickness measurements against computed tomography angiography (CTA), and to determine inter- and intra-operator reproducibility. Methods: The design was for a planned comparison of 3D-CEUS and CTA and of repeated 3D-CEUS measurements in a blinded set up. Consecutive patients with asymptomatic AAA (n = 137, maximum diameter 30-55 mm) from a single centre were consecutively assessed by CTA and 3D-CEUS in a blinded setup. After exclusion of failed CTA (n = 2) and inconclusive 3D-CEUS (n = 8), 127 3D-CEUS/CTA pairs were analysed by Bland-Altman plots. 3D-CEUS inter- and intra-operator reproducibility were determined in a subgroup (n = 30) measured twice by two blinded investigators. Results: In 24 of 127 (19%) patients, no ILT was found on 3D-CEUS. Intraluminal thrombus absence was confirmed by 3D-CTA analysis in all but two cases. Mean ILT volume difference between 3D-CEUS and CTA was 2.2 mL (5% of mean volume) and range of variability (ROV) amounted to +/- 10.2 mL. Mean ILT thickness difference was 0.6 mm with a ROV of +/- 4.6 mm 3D-CEUS inter-operator variations of ILT volume and thickness measurements were low (ROV +/- 8.8 mL and +/- 2.9 mm, respectively). The corresponding intraoperator ROVs were +/- 7.5 mL and +/- 3.3 mm, respectively. Conclusions: 3D-CEUS demonstrated good reproducibility and a good agreement with CTA when estimating ILT volume and maximum thickness in AAA patients. It is a promising research tool to investigate potential interactions between ILT, AAA growth, and rupture. (C) 2018 European Society for Vascular Surgery. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:673 / 680
页数:8
相关论文
共 22 条
  • [1] Mural Thrombus and the Progression of Abdominal Aortic Aneurysms: A Large Population-based Prospective Cohort Study
    Behr-Rasmussen, C.
    Grondal, N.
    Bramsen, M. B.
    Thomsen, M. D.
    Lindholt, J. S.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2014, 48 (03) : 301 - 307
  • [2] Applying the right statistics: analyses of measurement studies
    Bland, JM
    Altman, DG
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2003, 22 (01) : 85 - 93
  • [3] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [4] Three-Dimensional Ultrasound Evaluation of Small Asymptomatic Abdominal Aortic Aneurysms
    Bredahl, K.
    Sandholt, B.
    Lonn, L.
    Rouet, L.
    Ardon, R.
    Eiberg, J. P.
    Sillesen, H.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2015, 49 (03) : 289 - 296
  • [5] Three-dimensional Ultrasound Improves the Accuracy of Diameter Measurement of the Residual Sac in EVAR Patients
    Bredahl, K.
    Taudorf, M.
    Long, A.
    Lonn, L.
    Rouet, L.
    Ardon, R.
    Sillesen, H.
    Eiberg, J. P.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2013, 46 (05) : 525 - 532
  • [6] Volume Estimation of the Aortic Sac after EVAR Using 3-D Ultrasound - A Novel, Accurate and Promising Technique
    Bredahl, K.
    Long, A.
    Taudorf, M.
    Lonn, L.
    Rouet, L.
    Ardon, R.
    Sillesen, H.
    Eiberg, J. P.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2013, 45 (05) : 450 - 455
  • [7] da Silva ES, 2000, CARDIOVASC SURG, V8, P526
  • [8] Follow-up on Small Abdominal Aortic Aneurysms Using Three Dimensional Ultrasound: Volume Versus Diameter
    Ghulam, Q. M.
    Bredahl, K. K.
    Lonn, L.
    Rouet, L.
    Sillesen, H. H.
    Eiberg, J. P.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2017, 54 (04) : 439 - 445
  • [9] Size and location of thrombus in intact and ruptured abdominal aortic aneurysms
    Hans, SS
    Jareunpoon, O
    Balasubramaniam, M
    Zelenock, GB
    [J]. JOURNAL OF VASCULAR SURGERY, 2005, 41 (04) : 584 - 588
  • [10] Abdominal aortic aneurysm, arterial stiffening and the role of the intraluminal thrombus
    Hansen, Maria Lyck
    Thomsen, Marie Dahl
    Rasmussen, Lars Melholt
    Lindholt, Jes S.
    [J]. VASA-EUROPEAN JOURNAL OF VASCULAR MEDICINE, 2015, 44 (05) : 349 - 353