Ligasure versus Ultracision® in thyroid surgery:: a prospective randomized study

被引:74
作者
Sartori, Paola Vincenza [1 ]
De Fina, Sergio [1 ]
Colombo, Giovanni [1 ]
Pugliese, Francesco [1 ]
Romano, Fabrizio [1 ]
Cesana, Giovanni [1 ]
Uggeri, Franco [1 ]
机构
[1] Univ Milano Bicocca, Dept Surg, S Gerardo Hosp, I-20052 Monza, Italy
关键词
thyroid; surgery; hemostasis; Harmonic Scalpel; Ligasure;
D O I
10.1007/s00423-008-0386-3
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose New hemostatic technologies (NT) are often employed in thyroid surgery in the effort to reduce operating time and complications. The aim of this study is to compare three different hemostatic techniques. Methods This is a prospective randomized study. There were 150 patients, aged 56 +/- 14 years, randomized for total thyroidectomy with conventional technique (CT), Ligasure vessel sealing system (LI) or Harmonic Scalpel (HS) at the university surgical department. One hundred thirty-five patients had benign diseases; 15 had malignancies. Results Mean postoperative hospital stay was 2.6 days. Mean operation time was 113 +/- 31 min; in HS patients, it was significantly shorter (p<0.001). Morbidity was 43.3%; mortality was nil. Morbidity was significantly different between CT and NT groups (p=0.0002); HS and LI groups had a higher morbidity (p=0.0001 and p=0.02, respectively). Mean postoperative calcemia was 1.12 +/- 0.1 mmol/l with a significant difference between groups; NT patients had a significantly lower calcemia (p<0.05). There was no difference in recurrent laryngeal nerve palsies and in intraoperative blood losses (p=ns). Conclusions According to our experience, the only real advantage of new hemostatic technologies was a shorter operation time with HS.
引用
收藏
页码:655 / 658
页数:4
相关论文
共 18 条
[1]  
Ambrosi A, 2006, LANGENBECK ARCH SURG, V391, P47, DOI DOI 10.1007/S00423-005-0016-2
[2]  
[Anonymous], 1999, LIGASURE VESSEL SEAL
[3]  
[Anonymous], 2001, ULTRACISION HARMONIC
[4]  
BODDY SAM, 1987, UROL RES, V15, P49
[5]   A randomized, prospective, parallel group study comparing the Harmonic Scalpel to electrocautery in thyroidectomy [J].
Cordón, C ;
Fajardo, R ;
Ramírez, J ;
Herrera, MF .
SURGERY, 2005, 137 (03) :337-341
[6]  
Defechereux T, 2003, ACTA CHIR BELG, V103, P274
[7]   Risk factors of paralysis and functional outcome after recurrent laryngeal nerve monitoring in thyroid surgery [J].
Dralle, H ;
Sekulla, C ;
Haerting, J ;
Timmermann, W ;
Neumann, HJ ;
Kruse, E ;
Grond, S ;
Mühlig, HP ;
Richter, C ;
Voss, J ;
Thomusch, O ;
Lippert, H ;
Gastinger, I ;
Brauckhoff, M ;
Gimm, O .
SURGERY, 2004, 136 (06) :1310-1321
[8]   Sutureless and stapleless laparoscopic splenectomy using radiofrequency - LigaSure device [J].
Gelmini, R. ;
Romano, F. ;
Quaranta, N. ;
Caprotti, R. ;
Tazzioli, G. ;
Colombo, G. ;
Saviano, M. ;
Uggeri, F. .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2006, 20 (06) :991-994
[9]  
Gossot D, 1998, ANN CHIR, V52, P635
[10]   Use of a diathermy system in thyroid surgery [J].
Kiriakopoulos, A ;
Dimitrios, T ;
Dimitrios, L .
ARCHIVES OF SURGERY, 2004, 139 (09) :997-1000